Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Fluke287 electronic records True RMS Multimeter Fluke Multimeter

Fluke287 electronic records True RMS Multimeter Fluke Multimeter
Fluke287 electronic records True RMS Multimeter Fluke Multimeter
Fluke287 electronic records True RMS Multimeter Fluke Multimeter

Larger photo of automa dispenser

Company:Ma Technology Co., Ltd. of Shenzhen City
Information Name: Fluke287 electronic records True RMS Multimeter Fluke Multimeter
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Fluke 287 True RMS Multimeter FLUKE Multimeter electronic records can quickly record design performance and graphically displays what happened. With its unique recording and graphics capabilities, users do not record readings and then downloaded to the PC to analyze trends. Fluke Fluke 287 Multimeter for handheld into the unprecedented accuracy and ease of use, greatly enhance the user's ability to solve problems. It is demanding applications requiring high precision ultimate handheld measurement tools. Fluke FLUKE287 Key Features: Large 50,000 count, QVGA display with white backlight. And can display multiple sets of measurement information. Multimeters have a tendency to capture recording function is a necessary tool that not only can record the performance of your designs, processes or systems, and can be performed unattended monitoring work when the user is busy with other projects. It can store up to 10,000 readings and the data can be plotted as a line to help detect signal anomalies over time emerged. Onboard trend capture function, users do not need to use PC which can graphically view logged readings. (Optional software and interface table). Up more than 200 hours of continuous recording of multiple processes or data. This is designed to determine the performance characteristics or perform unattended monitoring very useful. "I" info button on board help screens to help users understand the measurements. Clear a function? Just go to this function, then press the "i" button. Saved measurements allow the user name and called in field data measured in real-time clock - automatically save readings plus stamp Field upgradeable and expandable meter lets users ready access to new features, to ensure that instruments to keep up to date Records events and trends - help eliminate intermittent problems or monitor the load. NEW - Multi-lingual interface soft keys, scroll buttons and easy navigation control, you can easily access the secondary functions. In addition, it can also create custom display. 0.025% basic DC accuracy 100 kHz ac bandwidth True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads. Measure up to 10A (20 A, for 30 seconds; 10A, continuous measurement) 100 mF capacitance range temperature relative mode function eliminates the low resistance or capacitance measurements existing test line impedance peak capture function to record transient signals The shortest time of up to 250 μs that comes with high performance test leads and alligator clips Optical USB PC communication interface allows for easy use FVF software (not included) for PC Download for archiving recorded data. Browse button allows the user to quickly select menu options and navigation information screen memory can record up to more than 200 hours of independent data for the minimum / maximum / average record signal fluctuations in time stamp function Fluke FLUKE 287 Technical Specifications DC voltage accuracy 0.025% range and resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V AC voltage accuracy of 0.4% (rms) range and resolution of 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V , 1000.0V current DC accuracy of 0.15% of range and resolution 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A AC Current Accuracy 0.7% (rms) range and resolution 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A temperature (without probe) Accuracy 1.0% range and resolution of -200.0 ° C to 1090.0 ° C (-328.0 ° F to 1994.0 ° F) Resistance Accuracy 0.05% range and resolution 500.00?, 5.0000 k ?, 50.000 k ?, 500.00 k ?, 5.0000 M ?, 50.00 M ?, 500.0 M? capacitance accuracy of 1.0% range and resolution of 1.000 nF, 10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100.00 mF? frequency accuracy of 0.005% + 1 range and resolution of 999.99 kHz FLUKE 287 additional functions / features multiple screen is True RMS AC bandwidth 100 kHz DBV / dBm is the conductivity 50.00nS buzzer off temperature (° C & ° F) -200 ° C to 1090 ° C battery / fuse access the battery / fuse Peak 250 μS timing clock is a clock is the minimum - maximum - average from 0.01 to 99.99 percent duty cycle pulse width 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms is insulated to keep the optical interfaces are automatic / Touch Hold is reading memory is recorded to the PC is the time interval / event record is a record store up to 10,000 readings FLUKE 287 Environmental Specifications Operating Temperature -20 ° C to +55 ° C Storage temperature -40 ° C to +60 ° C Relative Humidity 0% 至 90% (0 ° C to 37 ° C) 0% 至 65% (0 ° C to 45 ° C) 0% 至 45% (45 ° C to 55 ° C) Electromagnetic Compatibility EMC EN6 1326-1 Vibration Random vibration to MIL-PRF-28800f standard, two instruments strike one meter drop , in line with IEC / EN 61010-1 2nd Edition FLUKE 287 security features overvoltage category CAT III 1000 V / CAT IV 600 V safety standards CSA, UL, TüV, CE FLUKE 287 Machinery and general technical parameters of any terminals and ground 1000V maximum voltage between the high specification wire length x width x 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) Weight 870.9 g (28 oz) Battery life minimum 100 hours, 200 hours recording mode battery True RMS electronic record type 6 AA batteries, NEDA 15A or IEC LR6 Model Name Description Fluke 287 Multimeter has a tendency capture features All models include: Manual 6 AA batteries, TL71 silicone test leads probe sheath has been installed two alligator clips Supplement: registration card calibration Documentation User Manual on CD (16 languages) Getting Started Manual calibration certification tables Tag Tags: Fluke Multimeter Fluke Frankfurt Paul RMS 287 Electronic Records 
Contact Detail
Company Name: Ma Technology Co., Ltd. of Shenzhen City
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Zhu Lin()
Telephone Number: 0755-28105722
Company Address: Shenzhen, Shenzhen City, Guangdong, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450