Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Promotional spot -HP4284A_LCR tester

Promotional spot -HP4284A_LCR tester
Promotional spot -HP4284A_LCR tester
Promotional spot -HP4284A_LCR tester

Larger photo of automa dispenser

Company:Dongguan Mong Mau Tong Instrument Co., Ltd.
Information Name: Promotional spot -HP4284A_LCR tester
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Promotional spot -HP4284A_LCR tester -13,412,827,006 Ouyang R: 13412827006 Tel: 0769-87932051 Fax: 0769-82007511 QQ: 470515932 recycling plant idle / closed down electronic equipment, personal processing machines, please call technical indicators HP 4284A Precision LCR meter frequency performance. range: 20HZ-1MHZ impedance range: 0.01mΩ-100MΩ basic measurement accuracy: conductivity ρ 0.05% The main purpose of the test material, the dielectric constant ε, resistance R, reactance X, the impedance Z, the admittance Y, conductance G, susceptance B, inductance L, dielectric loss D, quality factor Q. You can complete the temperature spectrum of dielectric material testing, test Temperature range: -1000 ℃ · bridge HP4284A0.05% basic accuracy, resolution and six digit constant V or I test signal level · 20Vrms level option (Option 001) ? Use Alilent 42841A into 40Adc · have given a list of scan measurements Agilent 4284A Precision LCR Meter is the instrument used to measure the components and materials cheap. It does this by providing accurate, high throughput testing methods to improve the quality of components. 20Hz to 1MHz wide measurement frequency range and excellent test signal to 4284A in the test components to meet the most accepted test standards such as IEC / MIL standards, and work in simulated working conditions used. Both in research and development, production, quality assurance, or incoming inspection, 4284A LCR can meet all measurement requirements. Bridge HP4284A Technical indicators measured parameters | Z | -θ, | Y | -θ, RX, GB, CD, Q, ESR, G, Rp, LD, Q, ESR, G, Rp; deviation and% deviation measurement circuit serial and parallel mode range switching automatic and manual trigger internal, external and bus (HP-IB) to 1ms latency 0-60.00s stepping measuring four-terminal end of the test cable length Standard: 0 and 1m; 006 belt options: 0,1,2 and 4m Integration time: short, medium and long averaging: 1-256 programmable test signal: 20Hz-1MHz ± 0.01% 8610 selectable frequency test signals: standard: measuring open or shorted respectively end, and not on the DUT to choose a constant voltage or current programming: maintain the DUT selected voltage or current, and the device regardless of changes in impedance and test signals: constant level standard 4284A 5mV ~ 2V, 50μA-20mA 10mV-1V, 100μA-10mA Option 001 5mV ~ 2V, 50μA-200mA 10mV-10V, 100μA-100mA DC bias: Standard: 0V, 1.5V and 2V options: 0V- ± 40V range parameter measurement display range | Z |, R, X 0.01mΩ-99.9999MΩ | Y |, G, B 0.01nS-99.9999SC HP 4284A: 0.01fF-9.9999FL HP 4284A: 0.01nH-99.9999kH D 0.000001-9.99999 Q 0.01-99999.9 θ -180.000 ° ~ 180.000 ° Δ% -999.999% ~ 999.999% basic measurement accuracy | Z |, C, LD 0.05% 0.0005 complementary features: Measurement time: from the trigger command to the end of the measurement processor interface connector (EOM) Output 40ms typical measurement time is short medium long 830ms 190ms Option 001 DC bias current output of 100mA max Display: LCD dot matrix display: Displays measured values, control settings, compare limit and judgment, the list of scanned tables, self-test information and signaling correction open / short error is zero: eliminate measurement errors caused by stray parasitic impedance test fixture due to take the load: the use of a calibrated device as a reference to improve the measurement accuracy of a list of scanning function for up to 10 frequencies or test signal level programming. It can be a single test or test sequence, when installed on the 001 option, but also for the DC bias voltage comparator 10 test chamber (ten-bin) classification for measurement parameters. Input / output parameters for a measurement chamber count: 0-999999 list sweep comparator: HIGH / IN / low output for a list of the scan table is determined for each measurement point other functions: store / load: 10 instrument setups can the internal non-volatile memory for storing / loading. 10 additional setting also consists of a memory card to store / load all HP-IB instrument control settings, measured values, limit comparison list scan table and self-test results memory: memory buffer can store up to 128 measurements, and by GPIB output data, ASCII and binary data format 64 General Specifications Power Requirements 100/120 / 220V ± 10%, 240V 5% / - 10%, 47-66Hz power 200VA max operating temperature and humidity 0 ° ~ 55 ℃, at 40 ℃, relative humidity ≤95% Size 42mm (W) * 177 (H) mm * 498mm (length) (16.77 inches) * (6.97 inches) * (19.61 inches) Weight: about 16kg (35.2 lbs) The long-term Recycling Supply Rental: Oscilloscope network analyzer comprehensive test instrument spectrum analyzer signal generator noise figure analyzer audio analyzer digital multimeter frequency meter power meter programmable power supply impedance analyzer spectrum analyzer function signal generator LCR electronic tester electronic load multimeter calibrator Oscilloscope Calibrator high-pressure machine data acquisition receive / transmitter measuring receiver cable / antenna analyzer modulation Bluetooth tester analyzer GPIB card 
Contact Detail
Company Name: Dongguan Mong Mau Tong Instrument Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Ouyang Qi(Management Business)
Telephone Number: 0769-87932051
Company Address: Dongguan City, New Village neighborhood 63, Dongguan City, Guangdong, China
Zip/Postal Code: 523710
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450