_ Transfer molding method fan buy flat FRP (certified) _ Qingzhou molded fan
_ Transfer molding method fan buy flat FRP (certified) _ Qingzhou molded fan
Axial Fan Maintenance 1, the fan should be carefully checked before installation is due to packaging, shipping and damage, deformation, can be repaired properly after installation. The installation should pay attention to check the associated portion of loose leaves and duct clearance should be uniform, not touching. 2, connecting the outlet of the weight of the pipeline should not be borne by the fan duct installation should additional support. 3, in the axial fan inlet side must be fitted with air filter set, and installed protective wires. 4, the fan base must naturally engage the ground plane can not be beat bolt force the connection to prevent deformation of the base. When installing the level of foot correction application base, padded in order to maintain its horizontal position, and then tighten the bolt. 5, the axial fan mounted on the ceiling allowed, after installation, a trial must first turn. 6, after a long unused fan, when re-use, you must first check the coupling part is solid and reliable, and after commissioning, before official use. 7, after the official fan operation should be checked once a year for loose screws, wires skin is damaged, it is repaired according to their specific circumstances. 8, always pay attention to the fan in operation without abnormal noise, vibration is increased, and timely inspection repair. Detailed description molded axial fans: First, the technical performance: T35-11-type axial fan is the national committee structures to promote the use of an efficient low pressure fan, the machine low power consumption, low noise, and has excellent resistance corrosion. It can be used as industrial plants, machinery manufacturing, chemical industry, printing and dyeing, electroplating, pharmaceutical and other industries; theaters, hotels, office buildings, residential and other buildings. If wind shell removed, can also be used as a fan, but also in a longer exhaust duct, spaced installed in series, to increase the total pressure in the pipeline. Second, the fan type: T35 axial flow fan according to the size of the impeller diameter into NO2.8, NO3.15, NO3.55, NO4, NO4.5, NO5, NO5.6, NO6.3, NO7.1 , NO8, NO9, NO10, NO11.2 thirteen gauge, number of leaves for each gauge are both four. Leaves can be loaded into a 15 °, 20 °, 30 °, 35 ° five kinds of angles. Therefore, manufacturers of molded fan 0 profit, since the size of each gauge blade mounting angles, different speed spindle speed, the fan air pressure, air volume and the power consumption is not the same. Transmission: Motor selection at all levels, with the fan impeller directly coupled molded offer a unified, body shell made of a cylindrical shape, the direction of rotation is clockwise loose wire skin is damaged, be repaired according to their specific circumstances. Axial Fan Maintenance 1, the fan should be carefully checked before installation is due to packaging, shipping and damage, deformation, can be repaired properly after installation. The installation should pay attention to check the associated portion of loose leaves and duct clearance should be uniform, not touching. 2, connecting the outlet of the weight of the pipeline should not be borne by the fan duct installation should additional support. 3, in the axial fan inlet side must be fitted with air filter set, and installed protective wires. 4, the fan base must naturally engage the ground plane can not be beat bolt force the connection to prevent deformation of the base. When installing the level of foot correction application base, padded in order to maintain its horizontal position, and then tighten the bolt. 5, the axial fan mounted on the ceiling allowed, after installation, a trial must first turn. 6, the fan when not in use long after the molded fan fair prices, re-use, you must first check the coupling part is solid and reliable, and after commissioning, before official use. 7, after the official fan operation should be checked once a year for loose screws, wires skin is damaged, it is repaired according to their specific circumstances. 8, always pay attention to the fan in operation without abnormal noise, vibration is increased, and timely inspection repair. _ Transfer molding method fan buy flat FRP (certified) _ molded fan Qingzhou County by Wu Teng 庄传平 glass steel processing department. Wu County Teng 庄传平 FRP processing at (www.sdtengfei.com) is an industry leader in Shandong Dezhou, fans, ventilation equipment, over the years, the company implement the scientific management, innovation and development, the principle of honesty and trustworthiness, and satisfy customer needs . Biography leader in flat glass and steel with the staff warmly welcome all inquiries negotiations to create mass flat fiberglass better future.
Contact Detail
Company Name: | Teng Zhuangchuan Ping Wu County Department of FRP proce.. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Liu() |
Telephone Number: | 0534-2176158 |
Company Address: | Dezhou Wu Teng Chong County Development Zone, Germany City, Shandong Province, China |
Zip/Postal Code: | 253300 |
Find More Related Products
- Other factors affecting the..
- Solar water heaters with sp..
- PS carrier tape | PC load w..
- Solar water heater down pip..
- Solar water heaters dedicat..
- Solar water heater insulati..
- Fire exhaust fan core techn..
- AO Smith water heater facto..
- Anjou RDP3-J3-30RDP3-J3Q-40..
- Anjou (RDP2-J3-30 RDP2-J3 (..
- Aa fine? Oil pipeline, with..
- Gifts? ▎ band, with tropic..
- An explosion-proof} {such a..
- Anjou Boutique (AR) MI stai..
- Inorganic glass steel duct ..
- Anjou Boutique (AR) MI stai..
- Anjou Boutique (AR) tempera..
- Anjou Boutique (AR) with a ..
- Anjou Boutique (AR) single-..
- Anjou Boutique (AR) oil sel..
- Anjou Boutique (AR) 36V ref..