Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Magnetic float level gauge, stainless steel magnetic float level gauge, Jiangsu and Shanghai meter (certified merchants)

Magnetic float level gauge, stainless steel magnetic float level gauge, Jiangsu and Shanghai meter (certified merchants)
Magnetic float level gauge, stainless steel magnetic float level gauge, Jiangsu and Shanghai meter (certified merchants)
Magnetic float level gauge, stainless steel magnetic float level gauge, Jiangsu and Shanghai meter (certified merchants)

Larger photo of automa dispenser

Company:Jiangsu and Shanghai Automation Instrumentation Co., Mi..
Information Name: Magnetic float level gauge, stainless steel magnetic float level gauge, Jiangsu and Shanghai meter (certified merchants)
Update Time:2015-04-30
Validity:0
Specifications:Limited
Quantity:
Price Description: RMB/
Inquire Now
UHZ-50 / D series reed float level transmitter and supporting the motor starter controls for controlling industrial or civilian sink, water tanks, water towers and various chemical, reservoir level, but also to non-conductive liquids and suspended solids containing media. Features 1. overcome the impact of false detection level 2 within the contact area, the inert gas protection 3. carve off the high voltage and high current load without spark 4. The contact ablation small magnetic float level gauge, work 5. The six long-life control program, for different control systems control technical indicators: 200-8000mm (division beyond 4000mm section installed) output signal: reed contact 380V AC, 2A life 5x104 times to control the medium temperature: -20 ~ 100 ℃ Working pressure: 0-0.6MPa medium gravity: ≥0.4g / cm3 control sensitivity: 10mm Medium viscosity: ≤0.05Pa.S environment: temperature -10-55 ℃ temperature ≤85%, no severe vibration principle of magnetic work Float measured level move up and down along the measuring tube, which makes magnet reed instantaneous position within the catheter corresponding switching output signal corresponding to the position contacts, with the corresponding control circuit to complete the injection liquid extract automatic pump control, level control so that the prescribed range. Position with contact signal and the alarm circuit can alarm and control as a hazardous level (super cap, ultra-low). Structure of the controller from the junction box, measuring catheter, magnetic float, signal unit and mounting the upper and lower limit circle and so on. The controller should be installed to avoid bending and Britain earthquake, to prevent damage to internal signals. Control scheme HER-YKA series level controller can be used in conjunction with level control box, for 1-3 sets of 20KW or more injection pump for automatic control, but also comes with its own control circuit. Model to explain the principles and structure of 1, UHZ-50 / D system based magnetic float level gauge works: ⑴ magnetic level gauge its working principle is based on Archimedes top-mounted magnetic float level gauge, the float The weight of the float displaces a volume of liquid equal to the weight of the float principle with permanent magnets with the liquid level changes, the position of the float magnetic field lines (i.e., the actual position of the liquid surface) by the driving magnetic turned column, flap, when the liquid level rises, liquid translated into red; when the level drops, gas translated into white or black. Thus striking indicate level changes within the container. ⑵ display panel mounted on the scale, which can be directly read out the liquid level, the valve is installed in the lower body, for sampling and sewerage. 2, the main structure: ⑴ (common type), which is made up of body and float and panel frame and other components. Level gauge with the container top and bottom flange connection, connecting middle valve, mounted on one side. It is suitable for heat or cooling is not required, and the media on the occasion of austenitic stainless steel does not corrode. ⑵ (insulation type), its structure (1) based on the type of additional insulation spacer sleeve, connecting pipe insulation, heat the upper and lower connecting pipe and equipment insulation systems are connected, by opening the valve size to reach the desired temperature . ⑶ (side top type), which is made of a magnetic float, buoy, side-mounted body assembly, the panel frame and other components, the display position for the top side, suitable for high temperature, highly viscous media or side opening containers. ⑷ (top mounted type), it is the panel frame, top body assembly, guide tube, float and other components, the display position for the top of the explosion-proof magnetic float level gauge for underground storage tank type or a top opening media ran not the occasion. UHZ-50 / D magnetic levitation level gauge is used to directly indicate a variety of liquid level or pressure vessel pointer instrument on the table and industrial equipment commonly used in the glass gauge compared to it is not afraid of rupture, more clear indication for the role of the glass wall has viscosity of the oil-based liquid medium or hazardous media, especially the direct instructions. Instruments are purely mechanical structure, so stainless steel magnetic float level gauge when flammable and explosive work, intrinsically safe. LKZ-D for the top-mounted, can be used for underground tank level indicator or oil tanks and other containers. LKZ-C has strong anti-vibration capabilities for mobile devices, such as car use float level gauge installation instructions: 1, key operation zero key [Z], adjust the key [S], the function key [M ] operation contents of the operation method Remarks unlock button while pressing [Z] and [S] key for more than 5 seconds, you can unlock (LCD screen displays: OPEN). PV value to zero (ie, zeroing) will float directly over the zero position, after unlocking button, and then press the [Z], [S] button for 2 seconds, it will be the current PV value is set to 0 , (LCD screen displays: PV = 0) if the current PV value and the value of the deviation exceeds 0 50% FS, PV value to zero is invalid, (LCD screen displays: PVER) 4mA active migration of keys Zero point: The float position to zero, press [Z] key for 2 seconds, the transmitter will output 4mA current, complete zeroing operation. (LCD screen displays: LSET) 20mA active migration of key transfer point full: will float into full position, press the [S] key for 2 seconds, the transmitter output 20mA current, complete tune full operation. (LCD screen displays: HSET) Transmitter data recovery first press [Z] button, then power, continued to hold down the [Z] for more than 5 seconds, if the LCD screen displays OK, then you have the transmitter data restore to factory state, you can release the button, if LCD display FAIL, then the show has not been on the transmitter data backup, you can not restore the transmitter data to the factory state. Magnetic float level gauge, stainless steel magnetic float level gauge, Jiangsu and Shanghai meter (certified merchants) instrument provided by the Jiangsu and Shanghai Automation Instrumentation Co., Ltd.. Jiangsu and Shanghai Instrument Automation Instrumentation Co., Ltd. (www.xhyhck.cn) is specialized in "magnetic level gauge, pressure transmitter, flow meter," the business, the company adhering to the "honesty, hard service" concept, to provide you with the most quality products and services. Welcome to inquire! Contact: Cui. 
Contact Detail
Company Name: Jiangsu and Shanghai Automation Instrumentation Co., Mi..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Cui()
Telephone Number: 0515-85516228
Company Address: China Jiangsu Yancheng, Yancheng City, Jiangsu Province, China
Zip/Postal Code: 225300
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450