Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Fisher Fisher agents 49A0491X012 regulator

Fisher Fisher agents 49A0491X012 regulator
Fisher Fisher agents 49A0491X012 regulator
Fisher Fisher agents 49A0491X012 regulator

Larger photo of automa dispenser

Company:Xiamen Corbett Automation Technology Co., Ltd.
Information Name: Fisher Fisher agents 49A0491X012 regulator
Update Time:2015-04-30
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
FisherS201 Self-series regulator, Fisher289 self-operated relief valve series regulator, FisherR622 Self-series regulator, Fisher Regal3 series, Fisher B249 series, Fisher 289 series, Fisher control valves, Fisher regulator, Fisher control valves , Fisher gas regulator, Fisher Fisher regulator, Fisher Fisher gas regulator, Fisher Fisher valve DVC6000 Series digital valve controller DVC6000 Series digital valve controllers can communicate, based on micro The processor converts the electrical signal into a pneumatic signal instrument. In addition to the electrical signal into a pneumatic signal that traditional functions, DVC6000 Series digital valve controllers can be used HART? Protocol, it is easy to access information critical to process operation. This function can be in the vicinity of the valve or in the field junction box with a 375 Field Communicator in the control room using a personal computer or a system console to achieve. Utilizing HART communications protocol information can be integrated into the control system or to a single loop basis acquisition. DVC6000 Series digital valve controller can be used single or double acting actuators. Digital valve controller connected to the valve stroke position feedback and pneumatic pressure and supply air pressure actuator. This allows the instrument to diagnose not only itself, but also the valve and actuator diagnosis it is mounted. This provides an economical and effective maintenance information for you, so when you actually need to be able to meter and valve line necessary repairs. Wiring is economical because DVC6000 Series digital valve controller with 2-wire loop-powered 4-20mA's. This is to prepare the conditions for the low local to replace the existing analog meter. DVC6000 Series digital valve controllers 2-wire design features to avoid the high cost of laying power and signal lines separately. DVC6000 Digital Valve Controller Specifications provides configuration mounted on the valve instrument DVC6010: applied straight stroke control valve DVC6020: Rotary and long-stroke applied straight stroke control valve DVC6030: applies to 90-degree rotating valve remote control Installation of the instrument (1) DVC6005: Basic unit for 2-pipe or wall installation DVC6015: Feedback unit applied to straight travel valve DVC6025: Feedback unit applied to the rotary valve stroke and long stroke linear DVC6035: Feedback unit applies 90 degree rotating valve DVC6000 Series digital valve controllers can be mounted on Fisher and other manufacturers rotary and sliding-stem actuator input signal (2) Point to Point mode: analog input signal: 4-20mA DC standard; the ability to provide a breakdown of the process requires a minimum voltage at the terminals of the instrument must get 10.5 volts DC for analog control, while the HART communication minimum voltage of 11 V DC (see guidance booklet meter) Minimum Control Current: 4.0mA minimum current without cause microprocessor restart: 3.5mA maximum voltage: 30 volts DC Overcurrent Protection: Input circuit limits the current to prevent internal damage Reverse Polarity Protection: Reverse loop current multi-way damage does not occur: instrument power supply: about 8mA When is 11-30 volts DC reverse polarity protection: Reverse loop current does not occur damage to the output signal required pneumatic actuator signal, the maximum supply pressure of up to 95% of the minimum range: 0.4bar (6psig) Maximum range: 9.5bar (140psig) mode of action: double-acting, single acting positive-acting, single-acting reaction type gas pressure: The recommended minimum pressure: higher pressure than the maximum actuator requirements 0.3bar (5psig) Maximum pressure: 10.0bar (145psig), The maximum pressure rating of actuator, whichever is lower. Steady-state air consumption standard amplifier: gas pressure is 1.4bar (20psig): Less than 0.4 standard m3 / hr (14scfh) supply pressure 5.5bar (80psig) when: less than 1.4 standard m3 / hr (49scfh) low Air Amplifiers: gas pressure is 1.4bar (20psig) when: an average of 0.056m3 / hr (2.1scfh) supply pressure 5.5bar (80psig) when: a standard average of 0.184 m3 / hr (6.9scfh) Maximum output Capacity: at 1.4bar (20psig) supply pressure: 10.6 standard m3 / hr (375scfh) at 5.5bar (80psig) supply pressure: 31.1 standard m3 / hr (1100 scfh) Independent Linearity: output range of ± 0.50 % of electromagnetic interference (EMI) according to IEC 61326-1 (version 1.1) tested for compliance with grades A (Industrial) and radiation intensity level B (home environment) devices, according to the plant area Immunity requirements (Table A.1), anti-jamming performance in Table 1. Electrical Classification Hazardous area: to provide compliance with CSA, FM, CENELC and SAA standards of proof, Intrinsically Safe, Division 2 and fireproof structure. See Hazardous area classifications sample 9.2: 001 series and 9.2: 002. According to ANSI / ISA-82.02.01-1999 (IEC610101-1 Mod) standard pollution level 2, overvoltage category III. Shell Electric rating: conform NEMA 4X, CSA Type 4X, IEC60529, lP66. 1151DP3E12 PRESSURE TRANSMITTER 472 FURNACE CONTROL 1151DP3E12B1 PRESSURE TRANSMITTER 48A0587 2340/41 OUTPUT 1151DP3E2AB3P2 PRESSURE TRANSMITTER 48A6868 PCB 1151DP4E12 PRESSURE TRANSMITTER 49A0491X012 TEMP TRANSMITTER MODULE 1151DP4J12 PRESSURE TRANSMITTER 49A0491X022 TEMP TRANSMITTER MODULE 1151DP4S12 PRESSURE TRANSMITTER 49A0494X012 TEMP TRANSMITTER MODULE 1151DP4S12M4B1 PRESSURE TRANSMITTER 49A7243X0AR PCB 1151GP5E22B1P2 PRESSURE TRANSMITTER 49A8569X032 HIGHWAY INTERFACE BD 1151GP9E12 PRESSURE TRANSMITTER 49A8569X052 HIGHWAY INTERFACE BD 1151LLT4E12A0 PRESSURE TRANSMITTER 546 TRANSDUCER 1151LLT4E22A0 PRESSURE TRANSMITTER 646-31 TRANSDUCER 12B7588X05R DPR-900 CONTROL CD6201X1 OP MODULE 23403U8900D 2340/41 INPUT CD6201X1-EB1 OP MODULE 2390 LEVEL TRANSMITTER CD6201X1-EB2 OP MODULE 2390FM LEVEL TRANSMITTER CD6201X1-EB3 OP MODULE 24A3070B ALARM MODULE CD6201X1-FA1 OP MODULE 31B1834X032 PARA BUFFER BD CD6201X1-FA2 OP MODULE 32A2524X022 CONT SENSE MOD CL6242 INTEGRAL CTRL 32B9765X052 MUX SER INTERFACE BOARD CL6821 I / O MODULE 34A3136L3E CHART DRIVE BD CL6821X1-A5 I / O MODULE 34A3136L3F CHART DRIVE BD CL6821X1-A6 I / O MODULE 34A3136L3G CHART DRIVE BD CL6826X1-A2 OUTPUT MODULE 3582-10 VALVE POSITIONER CL6921SERX1 INTERFACE 3600 VALVE POSITION CL7001X1-A10 CONFIG CONTROL 3622 FLOWMETER CL7011X-A2-16 COMPUTING CTRL 36A0043L3B SERVO MODULE CL7011X1-A2 COMPUTING CTRL 36A0044X012 SERVO DRIVER BD CL7011X1-A5 CONTROL BOARD 36A0044X032 SERVO DRIVER BD CL7652X1-A2 DUAL C1A BD 
Contact Detail
Company Name: Xiamen Corbett Automation Technology Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Zhang Yong(Sales Engineer)
Telephone Number: 0592-3517007
Company Address: Huli District, Admiralty Road, Unit 7, 1504, Xiamen City, Fujian Province, China
Zip/Postal Code: 361000
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450