Champion Battery NP Series
Champion Battery NP Series
|
The company Beijing champion batteries, battery prices champion, champion batteries offer related products:? Beijing champion championship Battery Battery Battery champion championship battery price quotes Guangdong Zhicheng Champion Champion Battery Battery Battery Guangdong Zhicheng Champion gold dealers, has for many years been Chi Guangdong a champion battery company awarded the "outstanding agent" title, all batteries are original authentic, genuine, please customers and friends feel comfortable buying. (For more details, prices and models, etc., please contact) The following are the champions Battery Description: Champion Battery Type: Type Rated voltage (V) Rated Capacity 25 ℃ (AH) reference dimensions (mm) ± 2 Termination Type LWH total height NP4-6 6 4 70 47 101 105 E NP7-6 6 7 151 34 94 98 E NP10-6 6 10 151 50 95 99 E NP12-6 6 12 151 50 95 99 E NP120-6 6 120 195 170 206 209 F NP180-6 6 180 306 168 220 225 F NP200-6 6 200 323 178 224 227 F NP1.2-12 12 1.2 97 43.5 51 56 E NP2-12 12 2 178 34.5 61 65 E NP4-12 12 4 90 70 102 106 E NP5- 12 12 5 90 70 102 106 E NP7-12 12 7 151 65 94 99 E NP8-12 12 8 151 65 94 99 E NP12-12 12 12 151 98 98 102 E NP17-12 12 17 181 76 167 167 F NP24- 12 12 24 166 175 125 125 F NP33-12 12 33 196 131 163 180 G NP38-12 12 38 197 165 170 170 G NP55-12 12 55 228 138 208 227 G NP65-12 12 65 348 168 178 178 G NP70- 12 12 70 260 168 208 231 G NP80-12 12 80 260 168 208 231 G NP90-12 12 90 329 172 215 243 G NP100A-12 12 100 329 172 215 243 G NP100B-12 12 100 339 172 212 217 F NP100- 12 12 100 407 175 208 238 G NP105-12 12 105 407 175 208 238 G NP120-12 12 120 407 175 208 238 G NP150-12 12 150 483 170 241 241 G NP180-12 12 180 522 240 218 244 G NP200- 12 12 200 522 240 218 244 G champion battery applications: 2V, 12V series gel batteries are widely used in telecommunications, power sector of power and control systems, solar energy, wind power systems, large-scale UPS and computer power and other DC backup power supplies . Champion Battery Features: 1. fumed silica and various additives made of silicone gel, the structure of the three-dimensional porous structure of sulfuric acid can be adsorbed in the gel, and the gel is positive hairline cracks precipitated oxygen to the negative established channels, enabling the establishment of sealing reaction efficiency, the battery sealed, precipitation-free electrolyte and acid mist overflow, polluting the environment and equipment. 2. The gel battery electrolyte gel state, no flow, no leakage, can be vertical or horizontal display. 3. The grid structure: the median and corner tabs dislocation design, 2V series at the bottom of the positive electrode plate coated with plastic protective film can improve the reliability of the battery at work, using lead calcium tin aluminum alloy, the negative plate hydrogen evolution potential high. Positive plate alloy for the low calcium high tin alloy, its fine grain structure compact, good corrosion resistance, the battery has a long life characteristics. 4. separator gel batteries imported special corrugated PVC separator which baffle hole rate is high, resistance is low. 5. The battery slot cover is ABS material and epoxy sealed to ensure no leakage. 6. Poles pure lead material, good corrosion resistance, pole and battery cover with pressure ring structure is pressure ring and gasket to the battery pole achieve mechanical seals, bonded with resin sealants to ensure its seal Reliability. 7. 2V, 12V batteries possess the full range of air filter disk device, battery external encountered fire without detonation, and the precipitate is filtered gas to environmental pollution. 8. maintenance without rehydration internal resistance, high current discharge performance is good adaptation wide temperature (-35-45 ℃) self-discharge and long service life (8--10 years) charged the factory, easy to use security proof unique formula, deep discharge Recovery performance is no free electrolyte side down 90 degrees can still be used. Technical support services provided by the company: The company provides technical services, including telephone support and on-site support two to assist the user equipment failure timely resolved to ensure that equipment reliability, stable operation. 1, the telephone support service A, the user during maintenance, occur due to a technical fault caused by the equipment, which led to not work, can be requests for services to the Company by telephone. B, maintenance engineers, phone support team with the fastest time in response to user service requirements, to answer questions raised by users, assist and guide the user to develop solutions. 2, on-site support services A, in the case of telephone support was unable to properly solve the problem, we will within 48 hours to send technical personnel to the scene to help users troubleshoot. B, during the warranty period for the product, during the warranty period, we will free replacement due to technical problems of raw materials, design and manufacturing processes and quality issues and the failure of the product, and the buyer can not handle major issues, free provide replacement service and timely solutions to the various problems exist products and product repair problems. C, for product warranty expires, based upon the buyer's request to provide any equipment failure maintenance services, repair bad product in a timely manner to the best price replacement. Information services: 1, the product manual provided with the product and installation instructions. 2, according to user requirements design, installation, and provide product design and installation drawings. 3, according to user requirements to provide information about the performance of products and a variety of characteristic curves. 4, to provide training materials and training of relevant information required by the user. Champion Battery maintenance and repair: the use of UPS power supply system in the process, people often one-sided that the battery is maintenance-free and not take this seriously. However, our data show that the proportion due to battery failure caused by a host failure or UPS is not working properly is about 1/3. Thus, strengthening the proper use and maintenance of the UPS battery to extend battery life and reduce UPS power supply system failure rate, with more and more important. In addition to an optional battery other than regular brands, the following aspects should be proper use and maintenance of the battery: (1) to maintain the proper ambient temperature. Important factors that affect battery life is ambient temperature, ambient temperature is usually the best battery manufacturers claim is between 20 ℃ ~ 25 ℃. Although the temperature rise of the battery discharge capacity has increased, but the cost is greatly reduced battery life. According to tests measuring the ambient temperature once more than 25 ℃, each increased 10 ℃, the battery life would be shortened by half. UPS batteries currently used are generally VRLA batteries, universal design life of five years, which can be achieved at battery manufacturer demanding environments. Less than the required environmental requirements, there is a great difference in the length of its life. In addition, the increase in ambient temperature can cause the battery internal chemical activity increased, resulting in a lot of heat, in turn prompting the ambient temperature, this vicious cycle will accelerate shorten battery life. (2) periodic charge and discharge. UPS power supply system in the float voltage and discharge voltage at the factory have been commissioning rating, while the size of the discharge current is increased as the load increases, the use should be reasonable to adjust the load, such as computers and other electronic control the use of several devices. In general, the load should not exceed 60% UPS rated load. Within this range, the battery will not over-discharge. UPS connected to the mains due to long-term, high-quality power supply, power outages are rare use of the environment, the battery will be a long period of floating charge state, a long time will cause the battery chemical energy and electrical energy into each activity decreased, accelerated aging shorten life. Thus, generally every two to three months should be fully discharged once, discharge time can be determined based on the battery capacity and load size. After a full load discharge is complete, according to the provisions recharge more than 8 hours. Recommendations :( maintenance-free batteries, Panasonic batteries, Yuasa Battery, Germany sun batteries, Hills batteries, Dorset batteries, pine batteries, OTP battery champion battery)
Contact Detail
Company Name: | Beijing Yongsheng Technology Company |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Flying Horse(Sales Manager) |
Telephone Number: | 010-57123017 |
Company Address: | Zhongguancun International Building Block B, , Beijing, China |
Zip/Postal Code: | 100080 |
Find More Related Products
- Baidu Hills Hills battery 3..
- Ellis Ellis batteries batte..
- Rotary screen printing unit
- Efficient Dynamics laminati..
- Rotary vacuum packaging mac..
- Rockets where batteries are..
- Supply Qinzhou original Ger..
- Supply Anshan City, the sun..
- Recycling tetraoxo cobalt c..
- Supply of new Viagra tablet..
- Sunway supply laptop batter..
- Lithium-ion hybrid battery ..
- Standard battery detection ..
- Granville new factory direc..
- Supply Xinwei button batter..
- Will the new supply 5V6A ba..
- Domestic selling brand Shen..
- Fast and convenient profess..
- Supply Xinwei square batter..
- Supply power electric cars ..
- Pulse Test Sunway 5V50mA ba..