Battery sampling module
Battery sampling module
|
Acquisition module Technical parameters Model: IDEAL-B201CY Dimensions: 38 * 147 * 120 (mm) Basic functions: lead-acid batteries, nickel-metal hydride batteries, lithium batteries, battery voltage, temperature acquisition, computation; product structure: master-slave structure ; master control box can control up to 256 from the control box, each with up to 16 voltage can be collected from the control box, 8-channel temperature; Operating voltage: DC 18V ~ 36V (nominal DC 24V) Operating Current: ≤200mA (single module) Ambient temperature: -40 ~ 85 ℃ Relative humidity: ≤90% single voltage: DC 1 ~ 5V voltage display resolution: 1mV voltage measurement accuracy: ± 0.2% (FS) Temperature range: -40 ~ 80 ℃ Temperature measurement accuracy : ± 1 ℃ cell voltage sampling period: 100mS cell voltage polling cycle: Maximum: 2.4S communication features: CAN Communication / RS485 communication and alarm functions: data and relay output (total voltage, single temperature, voltage, charge and discharge current ) ultracapacitor Note 1, super capacitor has a fixed polarity. Before using, make sure polarity. 2, ultracapacitors should use at nominal voltage: When the capacitor voltage exceeds the nominal voltage, will lead to decomposition of the electrolyte, while the capacitor may have a fever, decreased capacity and increased internal resistance, shortened life expectancy, in some cases, It may lead to the collapse of the capacitor performance. 3, ultracapacitors can not be used in high-frequency discharge circuit, the high frequency of rapid charge and discharge can cause internal capacitor fever, capacity fading, resistance increases, and in some cases can lead to the collapse of the capacitor performance. 4, life supercapacitors: ambient temperature for life supercapacitors have a significant impact. The capacitor should be kept away from heat sources. 5, when the super capacitor voltage drop is used as back-up power supply: As the super capacitor has a large internal resistance characteristics, there is a voltage drop in an instant discharge, ΔV = IR. 6, the use of ambient gas: super capacitor may not be at a relative humidity greater than 85% or spaces containing poisonous gases, under these conditions can lead to corrosion of lead and a capacitor case, resulting in disconnection. 7, ultracapacitors store: super capacitors do not exposed to high temperatures, high humidity, the temperature should be -30 + 50 ℃, relative humidity less than 60% of the storage environment, avoid temperature surges and sags, as this would lead to product damage. 8, super capacitors used in the double-sided circuit board: When the super capacitor is used double-sided circuit board, you need to pay attention to the connection via the capacitor can not reach the place, since the installation of a supercapacitor, can cause a short circuit. 9, when the capacitor soldered at the circuit board, the capacitor case must not be exposed to the circuit board, or welding material will penetrate to the capacitor threaded hole, have an impact on the performance of capacitors. 10. After installing super capacitors, the capacitor can not be forced to tilt or twist, this will cause the capacitor wiring loose, resulting in performance degradation. 11, during the welding process to avoid overheating the capacitors: If there is overheating in the welding manipulation capacitor will reduce the life of the capacitor, for example: if you use a printed circuit board having a thickness of 1.6mm, the welding process should be 260 ℃, time is not over 5s. 12, cleaning after soldering: the capacitor after soldering, circuit board and capacitor need cleaned, since some impurities may cause the capacitor to short circuit. 13, when the capacitor in series: When the super capacitor in series, there is a problem voltage balance between monomers, a simple series will result in one or a few monomer capacitor overvoltage, causing damage to the capacitor, the overall performance is affected , so the capacitor in series, the need to get the manufacturer's technical support. 14, Other: Other issues on the application appears in the process of using ultracapacitors, please consult the manufacturer or reference to the relevant technical information super capacitors for use in the implementation of the US-owned Zibo Ideal Control Technology Co., Ltd. Tel: 0533-6282806 Fax: 0533-6282811 Company Address: Shandong Zibo City High-tech Zone government channel 135 Pioneer Park, Block E, three production Address: Zibo City, Shandong Province High-tech Zone of Advanced Manufacturing Industrial Park Road, Building E-mail: zbideal @ 163. com online QQ: 1095003828 24-hour telephone: 13153396271 Li, electric buses, electric cars ,, battery optimization systems, electric bus optimization
Contact Detail
Company Name: | Ideal Control Technology Co. Zibo |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Lee() |
Telephone Number: | 0131-53396271 |
Company Address: | Zibo, Zibo City, Shandong Province, China |
Zip/Postal Code: |
Find More Related Products
- Jinan City, where selling t..
- Battery Recycling waste bat..
- AB PLC Lithium Battery 1771..
- AB PLC Lithium Battery 1770..
- CR2450 battery clip 2450 do..
- CR927 manganese battery cli..
- Battery equalization module
- 9V battery holder, 9V batte..
- Free Transfer tabs
- Battery Private Network
- ABB battery 07LE90
- Germany Lixin Electronic Te..
- Zhengzhou Germany sunshine ..
- Germany sunshine battery ge..
- Bosch Bosch electronic char..
- Tianjin battery charger, ba..
- Tianjin forklift charger, c..
- Tianjin Electric boat charg..
- Tianjin electric pallet tru..
- Tianjin inverter, transform..
- Tianjin generator battery c..