Faced with the project, the integrity of thermal insulation
Faced with the project, the integrity of thermal insulation
State Yun - "RFT-controlled storage phase change material saving insulation construction technology," a characteristic, method 1. This construction method, the construction flexible, high construction efficiency, short construction period, high construction quality. 2. Construction wide adaptation, can be used in concrete, the aerated concrete blocks, hollow concrete blocks, lightweight aggregate hollow blocks and other media, construction continuity. 3. Insulation of this method of construction, materials, organic matter and the presence of a base to form the free acid compounds penetrate porous substrate, forming community, ensure dry adhesion, and improved wet adhesion hedge ratio, with excellent adhesion. 4. After the insulating layer of the present method of construction of dry-formed inner material forming the silicon-oxygen tetrahedron structure, water immersion is not loose, not back, non-chalking, no distortion, ensuring their durable life. 5. This construction method internal fiber insulation bonded integrally intertwined to form extremely complex three-dimensional network structure, tensile strength, strong integrity, with wet breathing, can effectively prevent cracks. Product is non-corrosive, no pollution, no radiation, no smell, no poison green products, combustion performance of Class A non-combustible grade material. Its comprehensive feature traditional acoustic insulation materials can not match. Second, the scope of the present method can be used in industrial and civil construction, public buildings, substandard wall insulation (paint, tile); external wall insulation; partition walls, staircases and other parts needed insulation. Third, the process principle RFT-controlled phase change energy saving insulation materials are critical use of plant extracts, the new technology of vacuum freeze-analysis layer, distillation, saponification compound from the principle of the use of phase-change technology to save energy and new materials. It breaks through the traditional insulation material having only a single thermal resistance, has thermal resistance and thermal insulation properties of the two. Apply to walls, ceiling and other surfaces, after naturally dried to form a seamless whole closed stable insulation. When the ambient temperature falls below a certain value, the phase change material is solid from the liquid condenses, releasing heat when the ambient temperature is above a certain value, the phase change material from a solid to a liquid melt, absorb heat, so temperature relative balance. Fourth, process and operating points 1. Process: primary treatment → paste → layered cake smear RFT material → laying alkali fiberglass mesh → Check → Cleanup 2. Operation points: 2.1 Primary treatment will end plate or concrete debris, blocks and other plaster surface clean, for reinforced concrete structures, concrete should be removed on the projection and template residual seams or sponge paper tape clean. The substrate to remove dust, water spray, making it moist. At the same time respond to the construction site of the ground floor for cleaning, floor after RFT controlled in order to facilitate the clean-up plaster plastering generated phase change energy saving insulation material. 2.2 RFT cake thickness control point using energy-saving materials set, size is 20 * 20, the required thickness of the insulation thickness, insulation thickness control point spacing is preferably less than 1.5m. 2.3 RFT saving delamination smear 1) spices: artificial press RFT material: water = 1: 2 (weight ratio) stir into a paste, with the mix with use. Note: Do not use mechanical agitation. 2) Apply the first layer of energy-saving materials RFT. Required thickness not exceeding 10mm, must be compacted surface left rough surface. 3) After the initial setting of the first layer, the second layer is applied, a thickness of not more than 15mm, and so on, until the design thickness. Precautions: Apply the next layer to be in front of a layer of material is not drying, and must stay between matte stratification. 4) Apply stratification, should be moderately pressed to ensure an effective bond between the layers, but not pressed wiping back and forth at the same site. In the painting, the bulge was found to produce, should be promptly removed wipe up. 2.4 laying alkali-resistant fiberglass mesh 1) RFT surface received light, the alkali-resistant fiberglass mesh with the trowel direct pressure on the surface, while the collection of light, non-leakage shop. 2) alkali-resistant fiberglass mesh cloth requirements laid flat, wrinkle-free, sequential lap, lap width of 30-50mm; when eave laying lap width 80-100mm; sun angle and incubated at Jiecha pressed against 100mm wide alkali-resistant fiberglass mesh. 2.5 Inspection and finishing 1) primary surface clean, Jiecha flat, no wiping pattern, line angle straight and clear. 2) Thermal insulation thickness must meet the design requirements, a single point of thickness measurement does not allow negative bias. 3) must be bonded insulation layer between the structural layer and the substrate as well as a solid, no delamination, hollowing and cracks. 2.6 Cleanup 1) after the completion of the wall painting, the construction site will be cleared up, it will drop RFT slurry timely recovery, re-use can be reused. 2) RFT insulation layer construction is completed, maintain good ventilation, dry environment, without the need for water conservation. Insulation conservation 7 days after the subsequent process of construction. Fifth, labor organizing labor organization table number of the workforce number Notes 1 material formulated by a construction worker 2 team, specific adjustments 2 applied according to the construction area and the schedule of workers 4 by a construction team, specific adjustments 3 Other personnel according to the construction area and schedule 1 is responsible for product protection, site clean-up, the number of environmental protection inspector 1 4 inspect the site of construction quality and approach the material quality 5 part-time security officer 1 may be part-time construction workers quality inspector can be adjusted according to the area of ??construction and construction schedule, according to the construction construction schedule to increase or decrease the number, the number of people listed in the table is based on a construction team, construction 150 m2 is determined daily. Six, materials and equipment and materials and machinery and equipment list No. Name Number of units 1 RFT-controlled storage phase change energy-saving insulation material package 50 without any mechanical equipment. The table area by 100m2 smear, smear 20mm thick insulation configuration, specifically, can be adjusted based on the actual amount of construction and engineering progress. Seven Quality Control 7.1 Quality Control Control standard 1) RFT-controlled storage phase change energy-saving insulation material insulation construction quality inspection according to "Building Decoration Engineering Quality Acceptance" GB50210-2001, "energy efficient building construction quality acceptance" GB50411- 2007, the requirements of the relevant provisions of the "Tianjin Energy conservation construction and acceptance" DB29-126-2007 other standards of conduct. 2) its burning properties of "building materials and combustion performance classification" (GB8624-2006) Class A standard. 7.2 Quality control points: 1) Primary treatment: primary wall vertical flatness should meet the quality requirements of structural engineering. Grass surface should be clean, no topsoil, no oil, no hollowing, loose and projection should be removed, the interface should be uniform. Such as flatness, squareness errors greater than 10mm, should be used for leveling cement mortar, leaving hair face, and the need to ensure the cement mortar layer does not hollowing cracking. 2) Material Properties: The insulation layer construction, the factory should check the material certificate of type inspection report, the appropriate batch factory inspection reports, site acceptance records. 3) The insulation layer thickness: When insulation thickness of more than 10mm, should be layered painting, coating thickness of each layer should not exceed 15mm. 4) Material Control: RFT saving insulation materials should be stored in the warehouse, moisture-proof anti-rain. Also prevent dust, pollution of the environment. 5) Insulation thickness test ⑴ insulation layer thickness shall meet the design requirements, the random sampling of parts used acupuncture, insulate the thickness test with the probe and ruler, do not allow a single point thickness testing negative bias. ⑵ test methods: On the insulation layer 100mm * 100mm block any delimitation, taking 5:00 measuring probe in the four corners and the center of the box, take the average as the insulation thickness value. With a floor area of ??100m2 insulation inspection lot, less than 100m2 also serves as a test batch. Each inspection lot should be at least one sampling, each sampling at least 5 points, each point spacing of not less than 1m. ⑶ determine the rules: All measurement point thickness value must be greater than or equal design thickness, it is determined that this batch of insulation qualified, otherwise this batch of insulation to be ineligible. 6) must be bonded to the wall and the insulation layer between each layer of solid structure, no delamination, hollowing and cracks. In a random sampling of parts used observation, percussion method for testing. 7) Batch retest site and project (1) RFT Material: 500m3 of each batch is also a group of less than 500m3. Review project: dry apparent density, compressive strength, equivalent thermal conductivity, linear shrinkage. (2) alkali-resistant fiberglass mesh: 5000m2 per one batch is also a group of less than 5000m2. Review project: breaking strength, tensile strength retention. All projects must meet the specifications and re-examination of the design requirements. Eight safety measures 8.1, earnestly implement the "safety first, prevention first" approach, clear safety production responsibility. 8.2, construction workers should strictly abide by the state laws and regulations relating to safety, to comply with the construction site security system. 8.3 Production (Safety) Manager has overall responsibility for safety management, organization of production safety leading group set up by the security officer supervises the execution in order to achieve the goal of safe production. 8.4 RFT insulation applied before construction work should be developed targeted safety technical tests, and to carry out tests, construction workers, fulfillment of the signature confirmation procedures, and frequently check the implementation and correct violations. 8.5, the construction work must abide by the rules, to enter the construction site must wear a helmet, smoking is not allowed on-site, high-altitude climbing operations should be prepared to security, the job of the frame body should guardrail, workers should wear seatbelts. 8.6, all the construction site of the hole must be cover, fencing, sheds, and the warning signs. 8.7 Construction site temporary electrical power should be based on construction design requirements for temporary arrangement, and distribution facilities must be well grounded to protect, switch box leakage protection device must be set. Nine, environmental protection measures 9.1 strict construction site management, engineering garbage piling point. Should clean debris and clean the site before construction work inside, cleaned the ground floor, completion of construction work completed, materials should be kept to do, clean the floor clean RFT slurry on the ground floor, can be reused reused. 9.2, RFT material piled up in warehouses, and with the color of the cloth cover to prevent dust. Ten, energy-saving and environmental protection performance in Table 1 are several insulation materials insulation materials comparison table names thermal conductivity (w / mk) the relative thickness of the insulation layer than RFT-controlled Phase Change saving insulation material 0.03 1.0 0.042 1.4 extruded polystyrene board insulation board Insulation Adhesive Polystyrene insulation 0.038 1.27 0.060 2.0 RFT-controlled phase change storage energy performance of energy-saving insulation materials is consistent with the three-step energy requirements, with a Class A fire performance, do not produce poisonous gases in case of fire, the fire performance is much better than extruded polystyrene board and board. Meanwhile RFT phase change material from thermostat thermostat phase change mechanism, can reduce energy waste, saving up to 65%, with considerable social and economic benefits, and therefore should be widely applied. Table 2 Several environmental performance of insulation materials comparison table: RFT-controlled phase change energy saving insulation materials powder polystyrene particles polystyrene board (EPS) material properties break the traditional single thermal performance of insulation materials, thermal capacitance and resistance the compressive strength of two single thermal insulation performance of a single thermal resistance compressive material reaches 114Kpa, it can be directly received light on the material surface, after the received light to form a hard film layer, its intensity can adapt putty thermal stress, reduce the cracking mortar layer. After forming loose material, polystyrene particles bond is not strong, can not directly receive light, it must be added to concrete and mortar layer surface-treated plate itself is low compressive strength, can only rely on the surface layer of cement mortar to maintain its surface strength, resistance the impact of the poor. Easily damaged and difficult to repair. Special construction crack resistance brucite fibers form a mesh tension structure to ensure the integrity of the material; and by the material and the wall surface of the alkaline hydroxide ion substitution reaction of the free acid form of non-physical height bonding, ensure the wall effective bond, combined with the material itself is a 5% volume expansion, fundamentally overcome the crack, crack. The ratio of the material is on site mixing, since the ratio of human action, there will be differences, this will between the different constituent material cracks. Sheet metal seams inevitably produce varying degrees by the thermal expansion and contraction cracks in the cracks prone to thermal bridges. Weathering phase-change materials are all from natural minerals, the physical treatment, of a small molecule, inert, stable performance to ensure stable performance of the material as a whole. Polystyrene insulation material surface protection is difficult if not long-term stable use. Once the surface is damaged, the powder particles due to the infiltration of water, so that the powder "wet back soft" adhesion loss of a large area off. Poor frost resistance, easy to aging, wind pressure. A class flame retardant Noncombustible. In the current fire rating is the highest level of wall insulation materials B1 B1 level environmental protection material does not contain radioactive elements radon and other harmful ingredients and phenol, crushing the powder particles are green products from recycled polystyrene board insulation materials on the market, recovery uncertain origin, hygiene uneven. Supporting environmentally friendly adhesive material is poor. Produced by the combustion of its benzene gas cause serious damage to the human body belong to daub construction construction, at the construction site just add water and stir, simple, no professionals. Quality can be guaranteed. Need professional team construction, complex process prone to quality issues, we need a professional team of construction and construction. Prone to quality problems. Economic construction is simple, no professional construction team, to save costs, shorten the construction period. Need professional construction team construction, high cost. Construction process complexity, need a professional construction team construction, high cost.
Contact Detail
Company Name: | Yun Technology Co., Ltd. Beijing State |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Xu Xiaoyu() |
Telephone Number: | 010-84410998 |
Company Address: | Sunny, Chaoyang City, Beijing, China |
Zip/Postal Code: |
Find More Related Products
- Plaster - filling block
- Taiyuan strength cement flo..
- Zhejiang high-strength fibe..
- Henan 12cm / 18cm / light p..
- Hubei strength cement fiber..
- Beijing Supply -RFT control..
- Chengdu logistics line to a..
- Bozhou 15cm / 18cm lightwei..
- Nantong from internal and e..
- Suzhou lightweight partitio..
- Huainan lightweight interio..
- Chuzhou high density cement..
- This year the best quality ..
- Which tile strong decorativ..
- Supply Three qi works for i..
- Three qi supply fire-resist..
- Advanced Acrylic Exterior P..
- Supply-weather resilient ou..
- Supply exterior paint
- Lime light of partition boa..
- Armstrong blasted surface m..