Home
Products
Henan Honda generator EL5000 Honda Honda 5 kilowatts of small power generator 5KW gasoline generator
Henan Honda generator EL5000 Honda Honda 5 kilowatts of small power generator 5KW gasoline generator
Henan Honda generator EL5000 Honda Honda 5 kilowatts of small power generator 5KW gasoline generator
Care and Maintenance and precautions unit: First, before regular maintenance and use of generator units, should use the appropriate grade of gasoline and oil according to the environment and conditions. Selection of appropriate or not for the reliability and service life have a great impact on engine performance mouth. 1, two-stroke and four-stroke gasoline engine is generally used in more than 90 or 90 grades of gasoline. Gasoline should be noted: In the hot summer and Alp regions, due to the high temperatures, low air pressure, prone to vapor lock, to strengthen the engine heat, so that the tubing insulation. Do not use leaded gasoline car wash oil as a solvent for oil, ethyl prevent lead poisoning. Do not use long-term storage of gasoline has gone, or gumming coke serious. Gasoline low flash point, flammable. Explosive. Easy to produce static electricity, you must follow on use, storage security measures gasoline. 2, the main effect of the choice of the lubricating oil is lubricating moving parts lubricated gasoline, and moving parts cooling cooling, cleaning, but also to prevent corrosion. Oil quality is good or bad and use right or wrong, not only affects the gasoline engine performance and service life, but also affect the oil's useful life. Should therefore be based gasoline ambient temperature, use the appropriate grade of oil. Minimum ambient temperature during the calibration, the oil should have good flowability, at the highest temperature, should have the appropriate kinematic viscosity, which is particularly important for air-cooled gasoline engine. Second, the use of gasoline generator gasoline generator set of environmental conditions in order to be stable and reliable operation under certain environmental conditions. The specific environmental conditions should meet the following requirements; 1. Ambient temperature is -20 ~ 40 ° C. 2.25 ° C when the air relative humidity less than 95%. 3. Altitude lower than 1000m. Altitudes above 1000m but less than 4000m, the internal combustion engine power correction table should reduce the output power to use. 4. Surrounding environment without mold. Environmental conditions affect 1. Effects of high temperature and high humidity environments. (1) affect the engine work reliably and life. Hot and humid environment is very conducive to the growth of mold, mildew engine products, leading to corrosion of metal parts, etc., affect the reliability and shorten the life of the unit. (2) the impact performance of the engine. Hot and humid environment inside the engine cooling slowly, machine temperature rise, resulting in decreased engine power output and make the appropriate accessories insulation aging, would greatly reduce the technical performance of the engine. Insulating film mold damage electrical equipment will fall, reducing insulation performance, resulting in deterioration of engine performance. (3) the impact of safe transceiver temperature and high pressure lead to mechanical corrosion, reduce the degree of insulation, not only affects the security of gasoline, but also a serious threat to personal safety. 2. Low air pressure at high altitude environment gasoline engine operate at an altitude of 1000m the following environmental conditions, gasoline function rated power output. Increasing altitude 1000m, since the air density decreases, the atmospheric pressure decreases, and poor fuel atomization and combustion air is bad, the output power will decrease by 11.5% ~ 12.2%. Thus, running at an altitude of 1000m to 4000m environments, gasoline engine power output shall be amended to reduce the value of the output power of gasoline use. Typically used in high altitude areas have chosen gasoline power larger than with gasoline as a power source, so that it has a greater power reserve. 3. When low environmental impact gasoline used under conditions of ambient temperatures below -20 ° C, the lubricants and fuel oil are thickened and become sticky, insufficient fuel gasification, fire difficult, resulting in difficulty in starting the gasoline engine. In order to ensure that the unit be able to start successfully within 20 seconds, so give the engine cold start measures, such as the lubricating oil heating. Third, gasoline generators up and running 1. Check whether the fuel tank, when no oil grade should be required to add. 2. Check the oil level in the crankcase, according to different seasons according to the instructions specified grade lubricant filling. 3. Check the oil passage is smooth, whether the ignition system is working properly; if abnormal phenomenon should be timely adjusted to exclude. 4. The fuel switch is not in the "ON" position, open the throttle. Cold shutdown when starting carburetor choke (do not choke off the heat engine shutdown shortly start again; to prevent too much fuel in favor of hard to start); the carburetor throttle appropriate off small; the gasoline engine point of switch settings "ON" position. 5. Manually start the system starting method with his left hand fixed unit, right hand pull start Round handle, pull the rope a little, when the claw was already starting to spin out of contact with the disk and coaxial rotation, then pull hard and fast to start the round smooth horizontal direction handle several consecutive weeks until the unit starts. 6. Electric starting system: electric start pressing the right button, the left controls the throttle, start the motor continuous working time should not exceed 10 seconds. As a start is unsuccessful, it should start again in the second two minutes later. As three consecutive unsuccessful start, you should check the reason. 7. After the unit starts, so start by means of resilient starter handle automatic recovery boot disk, when the gasoline engine is not allowed to work and then pull the drive wheels start to prevent damage to the institution, and gradually open the door after gale gasoline engine starts, until completely open, adjust the throttle, gasoline engine to run at low speed for 2-3 minutes, so that oil can be uniformly distributed in each of the friction surface. 8. The unit during operation, be sure to use an air cleaner; all parts are not allowed to tamper with the machine, not the operation Remove the oil dipstick to check the oil level and add fuel to prevent the resulting accident. 9. The unit must be in a well-ventilated conditions, prevent emissions, caused by poor working conditions and the deterioration in its operating personnel gas poisoning phenomenon. 10. When the unit is required to stop working, first cut off the power to the load to allow the engine to run at no load for 1 to 2 minutes, turn off the fuel switch, the ignition switch is in the "off" position, so that the gasoline engine to discontinue work. Not allowed to bring the load down, otherwise it will cause heat concentration, damage gasoline. Gasoline in the near future has not yet cooled down, remember not to touch the hot parts of the gasoline engine and muffler to prevent burns; heat engine can not be packaged into the box immediately after the store must be completely cool to avoid heat causing a fire; not allowed to shut off the choke; Avoid too much oil in favor of difficult to start again, or heavy oil residues accumulate fouling gumming blocked passage. Fourth, long-term storage and storage when not in use generators, storage needs, and its methods are as follows: 1. External cleaning, cleaning up after the release of crankcase lubricants, heating oil and then the nephew Pro crankcase. 2. Start the unit, empty running 2 to 3 minutes, put the net down oil. 3. The fuel discharged from the tank, and then from the fuel filter and carburetor drain fuel. 4. Remove the spark plugs, injection 10ml oil 3-5 after rotation of the crankshaft rotation, stop pulling until you feel heavy. 5. On the uncoated metal surface is coated with industrial Vaseline, paraffin paper and then wrapped with cloth cover in gasoline surface. 6. Vent wrapped with oil paper and rope (to prevent entry of foreign materials and moisture). Electric starter motor and the battery should be removed to their charging. Store in a dry place and charged once a month, not the battery that overheated or too cold place (less than 0 or greater than 30 ° C). [Businesses]: Zhengzhou Tiger Electronics Co., Ltd. [Store Address]: Zhengzhou technology market Po Garden, Building 17, Unit 5, 1st Floor East households [toll-free]: 0371-63661728 158-9005-2876 [Shop Address ]: http: //www.tgeups.com/
Contact Detail
Company Name: | Zhengzhou Tiger Electronics Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Xie(Business Sales Manager) |
Telephone Number: | 0371-63661728 |
Company Address: | Zhengzhou City, the Po Garden, Building 17, Unit 5, 1st Floor East households, Zhengzhou City, Henan Province, China |
Zip/Postal Code: | 450000 |
Find More Related Products
- Henan 10KW Honda petrol gen..
- Hills UPS power supply Hena..
- Shan County, where the sale..
- How much power Henan APCSUA..
- Jin Wushi DK600UPS How much..
- Luoshan where the sale of t..
- Dragon God Enterprises | fr..
- Mall where generators sell
- The new county where the sa..
- Gushi where the sale of the..
- Huaibin where the sale of t..
- Interest county where the s..
- Huangchuan where the sale o..
- Xinyang, where the sale of ..
- Sui where the sale of the g..
- Zhecheng where the sale of ..
- Xiayi where the sale of the..
- Citizens where the sale of ..
- Yucheng where the sale of t..
- Ningling where the sale of ..
- Yanshi where the sale of th..