Forklift alarm
Forklift alarm
|
Forklift alarm Instructions With the rapid development of modern industry, production efficiency, production safety and product quality are all of an enterprise development, and these three aspects are mutually restrict and promote each other. To get the best fit of these three areas, the company's management must invest a lot of energy and time. Forklift today's modern industrial production as an important logistics transportation, since it is often with a large crowd at the factory where it's safe driving always restrict the operation of other departments, but the company's management and not all the time in the supervision how to supervise a class transport truck plant safety with the management of many companies has become a heart disease. The system is based on this situation developed, using today's advanced microcomputer control technology, intuitive digital display, two-speed detection, multi-level alarm control, and can be high-fidelity audio alarm detection speed settings and voice Power off Hold function. When the speed exceeds the system specified time period, to retain the maximum speed of overspeed alarm chime, even then unplug the power plug will alarm and display speed maximum speed until the administrator with a special remote control to disarm the alarm. This series includes two sensors, a client can only use one at the same time: one is a conventional metal sensors, and the second is a wireless sensor. One of the highlights of wireless sensor is easy to install, use a non-contact wireless sensor, which greatly improve the conventional product inconvenience of installation problems. ? Features remote setting function, within 10 meters of the remote control can be set;? A small remote control buttons, simple operation, complete functions;? 4 volume is adjustable, you can set the volume for different occasions;? External speaker alarm, loud and clear voice, sound Well, the alarm sound up to 120dB; two alarms:? super bright lights, audio alarm. ? External ultra-bright warning light truck speeding were lighting tips;? Use WTV series of voice chip as the alarm circuit core, the alarm voice can easily be replaced;? Two speed setting different levels exceeding speed, different voice prompts alarm;? alarm lock time is adjustable from 0 to 99 seconds, the truck speed for more than a preset speed, set the lock time over, it is automatically locked alarm;? waterproof rating of 8, can be soaked in water to work;? When using a metal sensor installation, you can use the oil off function;? using wireless sensors, greatly simplifying installation;? operating voltage range DC12V ~ 24V;? work low power consumption of only 5W. 2, the technical parameters of the host Operating voltage:? DC 12V ~ 24V wireless sensor operating voltage:? DC3V Host Power consumption:?? 5W lights load: Allows ≤100mA / DC12V alarm output loudness:? 120dB 3, remote control the appearance and function description Key Function Operation Description Unit 1 is applied to the data when the function is set up to increase 2 can decrease while the function setting allows the data down by 3 locking time setting Press one second to enter setup mode, press again to exit. Sec speed setting 4 Press for one second to enter the stage speed setting mode, press again to exit, press again to enter the second set state, short press Exit. Km / h 5 Volume setting Press one second to enter setup mode, press Exit 6 10 m Pulse setting / wheel diameter setting Press one second to enter setup mode, press Exit 4, the specific operating system power, digital display current speed, provided that: all the parameters have been entered, such as walking 10 meters of pulses (automatic acquisition through learning) or wheel diameter (by remote control settings), the speed of the two alarms. 4.1, the lock time is set when the truck continued speeding within the set time, the truck continued to issue a series of alarm voice alarm until unlocked stop the alarm. Press "3" key a second time (more than two seconds will automatically exit the setting mode), enter the lock time setting, digital display "LC00", the speaker issued a "beep" sound conduct prompt, "LC" indicates the current status Lock time settings, the last two digits of the lock time. Unit is "seconds." Press "1" key and the "2" key, can be set by adding or removing specific alarm lock time, the time ranges from 1 to 99 seconds, "-" for the unlock time setting. 4.2, the speed setting alarms press "4" key on the remote control for 1 second (more than two seconds will automatically exit the setting mode), you can enter the alarm speed level settings, digital display "A00.0", speaker "beep" sound conduct prompt, "A" represents the current state-level speed setting, the last three digits of the speed-level alarms. The unit is "km / h." Press "1" key and the "2" key, can be set by adding or removing specific speed. Press "4" button to exit the speed level set, the system automatically saves the data set. Long press the "4" key for one second to enter the speed of the secondary setting, digital display "B00.0", the speaker issued a "beep" sound conduct prompt, "B" indicates the current status for the two speed settings, press move "1" key and the "2" key to set a specific speed by increasing or decreasing. Press "4" button to exit the second set speed, the system automatically saves the data set. Level two speed settings and speed settings can be set via the operation "4" key to cycle. 4.3, volume settings for sound truck alarm output is set, there are four adjustable volume. Long press on the remote control "5" key a second time (more than two seconds will automatically exit the setting mode), to enter the volume setting, digital display "VL00", the speaker issued a "beep" sound conduct prompt, sound volume for the current setting size of the volume, press "1" key to set the volume increases, the "2" key to set the volume decreases. 00 mute, 03 is the maximum volume. Priority hardware volume control system, when dialed from the motherboard code switch at the set volume level (table No. 3, 4 states), the volume on the remote control to adjust as invalid. To "H" when the DIP switch to toggle ONDIP text terminal, when the digital side to toggle to "L". DIP switch operation state and the associated action effect in the following table. 4.4,10 meter pulse setting / wheel diameter 4.4.1, automatic learning to use metal sensor, the product has automatic learning, the use of wireless sensor settings can be found in wheel diameter 4.4.3. On a road 10 meters, long press on the remote control "6" key for one second, the buzzer "beep" sound conduct prompt, digital display read front display a 10-meter pulse number, start the truck Walking during the current read digital display to the corresponding pulse, after 10 meters to reach the truck stop walking, the digital display to read the number of pulses for the current, and then press the "6" button until the digital tube extinguished after all release, the system automatically saves the number of pulses, the buzzer also issued a "beep" beep, digital re-display the current speed. (Note: Enter the number of pulses of 10 meters accurately determine whether the gun's accuracy over speed alarm, so the distance of 10 meters must be accurate, complete exercise of the truck to a straight line 10 meters away) 4.4.2, manually learn when the same model in other the truck has been learning on the pulse after a good 10 meters, 10 meters pulses can be entered directly through the remote manually. Press "6" key for one second, the buzzer on the remote control "beep" sound were prompted by pressing a button "1" or "2" key to set the pulse number "1" key to increase, "2 "button to decrease. After setting, press "6" key for one second, LED all off, the system exits setting mode and save the data that has been set. 4.4.3 set the wheel diameter using wireless sensor, the product can automatically identify sensing mode, you can set the wheel diameter by remote manual. Press "6" key for one second, the buzzer "beep" is heard on the remote control were sound prompt, press buttons "1" or "2" key to set the wheel diameter (unit: cm), "1" key is increased, "2" key is reduced. After setting, press "6" key for one second, LED all off, the system exits setting mode and save the data that has been set. 4.5, the truck speed alarm set alarm speed, the system emits a sustained alarm tone. 4.6, the speed level alarm level alarm truck speed exceeds a set and maintain the 2 seconds, the system will start alarm lights blinking. This process will be maintained until the speed drops below the set low alarm rate, if the rate continues to increase the period to reach two alarm rate is set, the system immediately starts two alarm. 4.7, two alarm truck speed exceeds the set speed and maintain secondary alarms for 2 seconds, the system immediately issue a continuous "beep, beep" sound the alarm, this process will be maintained until the rate drops set The following two alarm rate. When the time exceeds the set speed lock-up time, the alarm lock current maximum speed speeding when the speed down, the alarm is still in alarm status, LED display the maximum speed when speeding, even unplug the power plug the When the maximum speed will alarm and display speed, until managers use the remote control to unlock only exit alarm condition. 4.8 off line (optional) off the oil function is optional, and only customer specified on the purchase this feature only with a forklift alarm function off the oil. Use of wireless sensor products are not off the oil function. When the truck traveling speed or more than two alarm rate, and meet or exceed the locking time, the system continues to alarm and locked automatically cut off the oil circuit. In unlock the alarm, the oil automatically connect. Wiring part of the detailed wiring method in Section 7. Under 4.9, unlock alarm method is locked in the truck alarm continuous alarm state, press "6" button for 10 seconds on the remote control, you can unlock the truck alarm, alarm sound stops.
Contact Detail
Company Name: | Chong Wei Electronics Co., Ltd. Shenzhen Concert |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Liang Yi Han(Product Sales Manager) |
Telephone Number: | 0189-88785947 |
Company Address: | C6 3 Floor Fuhai Industrial Zone, Fuyong Town, Bao'an District of Shenzhen City, Shenzhen City, Guangdong, China |
Zip/Postal Code: | 518000 |
Find More Related Products
- Supply proximity switch Han..
- JW211Z5
- JW211Z3 trip switch factory..
- XCKJ10541
- LX918120 trip switch factor..
- Yasuko switch manufacturers..
- Hirakawa logistics and frei..
- XCKJ167 trip switch factory..
- JLXK1411 trip switch factor..
- XCKM102
- Supply transparent pad, 3M ..
- Plastic Products
- Electrical appliances wood ..
- 3.2g Pressure Tanks Pressur..
- Bakelite lid cover high-gra..
- EPE sheet, EPE bags, EPE box
- Supply of Velcro, packing t..
- Supply EVA foam, EVA pad, E..
- Supply of thermal tape, the..
- Supply of silicone rubber p..
- Supply of conductive, therm..