Hebei best chlorine dioxide generator manufacturers
Hebei best chlorine dioxide generator manufacturers
Basic requirements 1), design and electrical design of the generator should be consistent with GB / T 4064 and GB 5083 or equivalent international standards and internationally recognized standards organization. 2), the generator uses PVC material shall comply with GB 4219 and QB / T 3802 or equivalent international standards and internationally recognized standards organization. 3) manufacture generators shall comply with JB 2932 or equivalent international standards and international organizations accredited standards. 4), the reaction system should be set generator safety explosion-proof equipment. 5), each pipe should be no leakage. 6), the raw material liquid delivery means should be linked. 7), the generator is running materials used hydrochloric acid, sodium chlorate shall comply with relevant national standards. Technical requirements 1), chlorine dioxide, chlorine dioxide generator production a) shall not be less than the rated generator; disinfectant solution b) generator, the chlorine dioxide (as chlorine meter) total mass percentage of chlorine of not less than 95%; c) as the main raw material of sodium chlorite conversion rate of not less than 80%. 2) yield available chlorine disinfectant chlorine dioxide generator compound a) shall not be less than the rated generator; disinfectant solution b) generator, the chlorine dioxide (as chlorine meter) of the total available chlorine mass percentage of not less than 55%; c) the main raw materials such as sodium chlorate, sodium chlorite conversion rate of not less than 60%. 3) In normal conditions, the life of the generator is not less than 5 years, the average time between failures of not less than 8000h. 4), the generator under normal conditions should have a good seal, the generator used indoors (with good ventilation, ambient temperature 5 ℃ ~ 40 ℃ appropriate), indoor environment, the concentration of chlorine should be consistent with HJ regulations / T 30, the maximum allowable concentration should be less than 1mg / m. Total 5), when used for drinking water, water disinfection chlorite, chlorate and other raw materials residues should not exceed 0.7mg / L. [2]?
Contact Detail
Company Name: | Green Water Treatment Equipment Co., Ltd. Weifang Yu-jie |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Wang(Sales) |
Telephone Number: | 0536-6536567 |
Company Address: | Zhucheng East Outer Ring Road East in the middle of Shandong Province, , Shandong Province, China |
Zip/Postal Code: | 262200 |
Find More Related Products
- Hebei best chlorine dioxide..
- Hebei chlorine dioxide gene..
- Which brand is good water p..
- Ozone disinfection process ..
- Spray deodorant device cure..
- Spray cooling Sterilization..
- Integrated water purifier
- FA-efficiency automatic wat..
- Moen Da COM-Intell programm..
- Provide new air purifier OE..
- Jiangxi bioreactor, Zhuchen..