U210B standard glass insulator
U210B standard glass insulator
|
U210B standard glass insulator insulator sub-insulation resistance measurement 1) Insulation resistance measurement is a measure of porcelain insulators, glass insulators, composite insulators of the insulation resistance. Purpose of measurement is to check the condition of the insulation insulator, we found insulator insulation deterioration and defects such as insulation breakdown. (2) 35 ~ 220kV overhead transmission line insulator insulation resistance measurement recommended 5000V megger measure. The eligibility criteria 1. The insulation resistance (1) insulator newly installed insulation resistance should be greater than or equal to 500MΩ. (2) the operation of the insulator insulation resistance should be greater than or equal to 300MΩ. 2. insulator deterioration determination principle (1) Insulator insulation resistance is less than 300MΩ, and greater than 240MΩ insulator can be judged to be low. (2) Insulator insulation resistance is less than 240MΩ insulator can determine a value of zero. Composite insulation generally do not use this method to test the insulation resistance. Insulator insulation resistance measurement sub 1) Insulation resistance measurement is a measure of porcelain insulators, glass insulators, composite insulators of the insulation resistance. Purpose of measurement is to check the condition of the insulation insulator, we found insulator insulation deterioration and defects such as insulation breakdown. (2) 35 ~ 220kV overhead transmission line insulator insulation resistance measurement recommended 5000V megger measure. The eligibility criteria 1. The insulation resistance (1) insulator newly installed insulation resistance should be greater than or equal to 500MΩ. (2) the operation of the insulator insulation resistance should be greater than or equal to 300MΩ. 2. insulator deterioration determination principle (1) Insulator insulation resistance is less than 300MΩ, and greater than 240MΩ insulator can be judged to be low. (2) Insulator insulation resistance is less than 240MΩ insulator can determine a value of zero. Composite insulation generally do not use this method to test the insulation resistance.
Contact Detail
Company Name: | Cutting-edge Electric Power Co. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Wang Shuanghai(Sales Manager) |
Telephone Number: | 0317-3860595 |
Company Address: | Hejian City, Shahe Town Development Zone, , Hebei Province, China |
Zip/Postal Code: | 062450 |
Find More Related Products
- FC70B Zigong standard glass..
- LXY-100 Nanjing standard gl..
- XWP-100 standard ceramic in..
- Guangdong ZA-6T post insula..
- Ceramic insulator glass ins..
- ZSW-20/2000 post insulators..
- LXY-240 glass insulator man..
- Glass insulators LXP series..
- Glass insulators FC210BP- c..
- Cutting-edge power lines po..
- Pin P-20M ceramic insulator..
- Date not wait, ultra low-co..
- Composite insulators insula..
- Hebei cutting-edge composit..
- Supply various models of hi..
- Dongguan composite insulato..
- Composite suspension insula..
- _ Recycling insulator insul..
- Hejian cutting-edge power t..
- Transistor gaskets, insulat..
- Supply of natural mica mica..