Watson cooler air conditioning Fig copper cooler
Watson cooler air conditioning Fig copper cooler
|
Cooler Caution (1) cooler surfaces should be regularly cleaning dust and impurities oil work to keep coolers clean surface; (2) to be installed on the inlet pipe filter, so both to avoid the incorporation of impurities to keep the water clean, but also to prevent the pipe blocked (3) filters should be cleaned regularly, otherwise they will lose the filtering effect; (4) If the temperature is below 0 ℃ environment, the unit should be shut down The water inside the cooler drained to prevent the cracking cooler and close the new valve can also be added antifreeze in the pipe. Cooler installation and use and maintenance of the fault belongs to the non-standard cooler industrial products, although the design process as much as possible the requirements of building professionals lookout channel design into a standard size, but is limited to underground construction complexity, diversity, often difficult to achieve. In the production installation used in the table between the cooler filled with concrete and civil engineering duct sealing, resulting in the demolition overhaul difficulties, this issue import and export through the cooler installation flange way solved. Cooler usual faults are: 1, dirty table cold light tubes and fins between the block: After running for some time, due to dust in the air stick in between cooler fins and the light pipe, so that all coolers or part of the area fouling the air circulation decline, affecting the surface cooler effect of heat transfer, fouling can be solved by such a failure regular cleaning table cooler approach. 2, leak: cooler perennial run in wet conditions, the pipeline and weld corrosion at easy, leak or running water. Only regular table cold pressure test, to prevent such incidents in order to make cooler safe operation. Tell us about the role of cooler: cooler, there are two: one fan coil heat exchanger, it features resolutions of the fan disk and the reaction is bound to send cold power (heat) the amount of the air volume. In normal air conditioner has a facility. Second group of air-cooled air-conditioning condenser fins. Application of refrigerants being table cooler heat, so that is a measure of freezing time gradually increased. AHU fan coil cooler, chilled water through an air conditioner outside activities (chilled water) through the tube to the heat transfer fins icing atmosphere, cool atmosphere brought after cooling fans will use the occasion Cooling , cooling water from the return cooling pipe cooler will attract heat to the refrigeration units emit heat, cool and then was sent back to cooler heat, ice through atmosphere, it has been repeated.
Contact Detail
Company Name: | Texas Watson air-conditioning plant |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Su Guozheng(Sales Manager) |
Telephone Number: | 0534-5087808 534-6351260 |
Company Address: | Dezhou Wu Lu right Tuen County Industrial Park, No. 188, Germany City, Shandong Province, China |
Zip/Postal Code: | 253000 |
Find More Related Products
- _ Watson cooler air-conditi..
- Ladybug Paradise Park, Jins..
- Jiaxing air cooler or chill..
- Watson air curtain air-cond..
- Watson FIG explosion-proof ..
- Watson air conditioning hea..
- Big Medicine Herbal Conditi..
- Spot ATS48C11Y45 / 110A Sch..
- EPS-YJS-2.2KW
- 2014 quality plastic bell r..
- ESA intended Sa (Fujian) ag..
- Mine heaters, heaters, air ..
- Cheung Fat suction fan
- Xindai chiller installation..
- Xi'an ups proxy c3ks compan..
- Xi'an ups power c3ks compan..
- Suzhou, Kunshan air shift m..
- p150 water conditioning wat..
- Prices spray cooling water ..
- Emergency power supply