Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Baotou KB0 preferred Kip electrical control protection switch

Baotou KB0 preferred Kip electrical control protection switch
Baotou KB0 preferred Kip electrical control protection switch
Baotou KB0 preferred Kip electrical control protection switch

Larger photo of automa dispenser

Company:Kip Wenzhou Electric Co., Ltd.
Information Name: Baotou KB0 preferred Kip electrical control protection switch
Update Time:2015-04-29
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
KBO-16C factory direct sales, stock, free shipping Contact: Zhengjing KB0 Brand: Wenzhou Kip Electric Co., KB0-16C / M16 / 06MF KB0 marketing area of ??Shanghai, Jiangsu, Zhejiang, Guangdong, Beijing city, Tianjin, Shandong, Guangxi, Hebei, Hunan, Shaanxi, Henan, Jilin, Jiangxi, Heilongjiang Province, Fujian, Shanxi, Sichuan, Anhui, Xinjiang, Gansu, Qinghai Province, Guizhou, Liaoning, Chongqing, Inner Mongolia, Tibet, Hainan, Shandong, Qingdao, Changzhou, Hefei, Zhengzhou, Shanghai, Tianjin, Guangzhou, Shenyang, Taiyuan, Zhengzhou, Hangzhou, Suzhou, Kunming, Nanjing, Shenzhen , Xiamen, Wuhan, Changsha, Jinan, Yantai, Datong, Nanning, Dalian, Harbin, Xi'an, Lanzhou, Yinchuan, Xining, Chengdu, Chongqing, Changchun, Guiyang and other places. KBO fields of application due KB0 control and protection functions integrated, The modular, compact structure, high level of environmental protection, high breaking short-circuit current capacity, short arcing distance, long life, the protection of full-featured, high performance and reliability of continuous operation, easy installation and maintenance operations and other one series of advantages, especially following applies systems: ■ industrial facilities △ metallurgy, coal, iron and steel, petrochemicals, ports, ships, railways and other areas of power distribution and motor protection and control system; △ motor control center (MCC), particularly intelligent electronic control system or require rated breaking capacity Ics of up to 80KA distribution control and protection systems; △ single-motor control and protection systems; △ Distribution Center ■ commercial and civilian facilities △ modern building lighting, power conversion, pumps, fans air conditioning, fire protection, lighting and other electrical control and protection systems; △ remote control lighting system. △ Hospital △ Information Processing Center (banks, municipal securities trading centers) △ telecommunications room △ commercial buildings (shopping malls, supermarkets, supermarkets, etc.) ■ infrastructure △ port or rail systems (airports, railway terminal, etc.) highway lighting or ventilation systems △ △ army post control and protection system (such as border posts, radar stations) ■ fire pump fire system △ various occasions, fans and other product features KB0 ◇ large short-circuit instantaneous protection: protection of current and rated switch body current is related to its current setting 20In ± 20%, the operating time t4≤2 ~ 3ms. ◇ transient short-circuit protection: protection of current and Electronic Release rated current is related to its current setting 16In ± 15%, the operating time t3≤0.1ms. ◇ short circuit short delay or definite time protection: protection of current and Electronic Release rated current is related to its setting adjustable current panel (6 ~ 12Ir1) ± 15% (motor protection), (3 ~ 6Ir1) ± 10% (Distribution Protection), the time delay setting time t2 = 0.2s ◇ long delay overload protection: protection of current and Electronic Release rated current is related to its setting current Ir1 panel Adjustable 0.4 ~ 1Ie, inverse-time characteristic is I2T = (1.5Ir1) 2t1, t1 is the setting time lapse when the current 1.5Ir1, distribution with t1 = 64s, motors t1 = 128s ◇ Phase, phase protection: Operate time for the 2s ◇ Unbalanced protection: any two-phase current difference of more than 50% Operate time is 2s ◇ overvoltage protection: three-phase 470 ± 10V, Operate time 5s ◇ undervoltage protection: three-phase 270 ± 10V, Operate time 5s ◇ startup delay : Short-circuit short delay or definite time without protection, setting time of 2s ◇ Fire Interface: DC 24V Fire Interface output (optional) ◇ leakage protection: residual current based on customer requirements, operating time ≤0.1s (time delay of 0.3 s) (optional) ◇ pre-alarm function: current adjustable ◇ online programming functions ◇ fault indication ◇ test function KBO-16C, KB0-16C, KBO-16C, KB0-16 ----------- -------------------------------------------------- ------------------- 
Contact Detail
Company Name: Kip Wenzhou Electric Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Cheng()
Telephone Number: 0577-62620075
Company Address: Zhejiang, , Zhejiang, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450