Home
Products
Temperature and humidity sensor for temperature and humidity control Tuaobosen electrical equipment temperature and humidity sensors Figure
Temperature and humidity sensor for temperature and humidity control Tuaobosen electrical equipment temperature and humidity sensors Figure
Temperature and humidity sensor for temperature and humidity control Tuaobosen electrical equipment temperature and humidity sensors Figure
Temperature and humidity sensors Tuaobosen electrical supply / Tel: 0731-23682318; Contact: Liu 18974101858; website: www.zhinengcaokong.com; Liling Ao Bosen Electric Factory specializes KS-1C temperature and humidity control, temperature and humidity monitoring Wholesale and so on. Over the years due to the excellent price, range, quality clearance, the majority of consumers praise! For more detailed information about the indoor temperature and humidity control prices, intelligent temperature and humidity control sales prices ,, greenhouse temperature and humidity control prices, etc., please call us! Temperature and humidity sensor Figure; Ao Bosen Electric Supply / Tel: 0731-23682318; Contact: Liu 18974101858; website: www.zhinengcaokong.com; Liling Ao Bosen Electric Factory specializes KS-1C temperature and humidity control, temperature and humidity monitor wholesale. Over the years due to the excellent price, range, quality clearance, the majority of consumers praise! For more detailed information about the indoor temperature and humidity control prices, intelligent temperature and humidity control sales prices ,, greenhouse temperature and humidity control prices, etc., please call us! I. Product Overview ;;;; way temperature control, the way humidity control, according to changes in ambient temperature automatic control the load, adjust the temperature and humidity to normal, with heating and cooling and dehumidification, humidification, and other functions. For electric power low voltage switch cabinet, box-type substation, high-grade thermostatic chamber (box), temperature and humidity control vegetable greenhouses and other places. Second, the technical requirements: ;;;; humidity control range: 0 ~ 100% RH ;;;; precision; 3%, resolution 1RH% ;;;; limit setting range: 10-99% RH ;;;; limit Range: 1 ~ 99% RH ;;;; Hysteresis Setting range: 0 ~ 100% RH (can be set) ;;;; temperature control range: -10 ℃ ~ 99 ℃ ;;;; accuracy of 0.5% Resolution 0.1 ℃, the ;;;; line setting range: 0-99 ℃ ;;;; lower limit range: -10 ℃ ~ 99 ℃ ;;;; hysteresis setting range: 0-99 ℃ (can be set ) ;;;; control output: 2 relay contact output active, upper or lower temperature, humidity, high or low limit ;;;; contact capacity: AC250V, 3A (resistive load) Max 5A. ;;;; Power supply: AC220V ± 20% ;;;; working environment: temperature -20 ℃ ~ 70 ℃, relative humidity ≤99% RH Third, the shape and installation dimensions: ;;;; Dimensions: 48x48x78mm ;;; ; hole size: 45x45mm (panel cutout) four settings: ;;;; according to wiring diagram to connect the sensor, power, panel digital tube displays the current temperature and humidity values. Button to enter the set state, the upper display cod, lower display shows 0, asked for a password, key plus one, minus one button. The default value is "8", after the setting is complete, press the "SET" key to enter the next operation. When the lower limit on the temperature and humidity, if used as the upper limit, such as 50 ℃ to start the fan, then the upper limit temperature is 50 ℃, the lowest temperature lower limit value, such as -10 ℃: ;;;; note. If the lower limit temperature control with, such as less than 5 ℃ to start the heater, then the temperature limit set at 5 ℃, the temperature of the upper limit set at 99 ℃. Temperature hysteresis: The return value is the temperature control, such as temperature hysteresis is 2 ℃, when the temperature is greater than the upper limit value of 50 ℃ to start the fan after cooling, when the temperature dropped to 48 ℃, the controller returns to the cooling stops. The lower limit device as above upper and lower temperature and humidity. Setting principle: Limit must exceed the lower limit, the lower limit + hysteresis can not be greater than the upper limit value, the upper limit - back the difference is not less than the lower limit set value. Temperature and humidity sensors Figure
Contact Detail
Company Name: | Liling Ao Bosen Electric Factory |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Liu Ying() |
Telephone Number: | 0731-23682318 |
Company Address: | Zhuzhou, Zhuzhou City, Hunan Province, China |
Zip/Postal Code: |
Find More Related Products
- SCB10-400 / 10 dry-type tra..
- Changzhou lithium bromide c..
- Beijing Shunyi central air-..
- Maintenance sales inverter ..
- Wuxi Wuxi dry-type transfor..
- Kunshan ABB-ACS310-03E-01A3..
- Henan supply air to water h..
- Xiamen to the logistics and..
- Imitation marble lines the ..
- Processing all kinds of tra..
- Changshu Changshu recovery ..
- Changzhou Huapeng dry-type ..
- pt200 sensor for automobile
- Multi-point thermal resista..
- Sign FTA Shanghai Financial..
- Aluminum shell, fan, temper..
- szdawe3w4 Shandong transfor..
- Zhenjiang, Nantong transfor..
- Jiaxing garment factory clo..
- PI7600R75G3F3 Powtran agent
- BWDK-S dry-type transformer..