Shenzhen Norhill large supply of intelligent control devices HYD-5600
Shenzhen Norhill large supply of intelligent control devices HYD-5600
Function 1, simulated instructions: Circuit breaker status indicator (passive contact input) circuit breaker position indicator (passive contact input) Closing, the closing contact is closed, the red light working position analog bar contacts are closed red vertical analog bar light sub-gate, the sub-gate contact is closed, when the green light experiment simulated the location bar contacts are closed, the green level simulation of the light Earth switch position indicator (passive contact input) Spring energy storage instructions (no Source contact input) contact closure, analog bar red light, said ground contact closure switch on the red lights that are energy storage Contact off, the green analog bar light, disconnect the ground contact is open, the red light Off, indicates that no energy storage Note: The loss of power in the state all of the flares are off, the above contact signal from the circuit breaker auxiliary contacts. 2, high pressure part of live instruction LED striking voltage (KV): bus voltage × 0.15 ~ 0.65, lockout Kai control voltage (KV): bus voltage × 0.65 3, temperature and humidity control part Sensor approach: two condensation + two channel temperature Logic: When the ambient temperature is less than 5 degrees or humidity higher than 85% RH, the device starts heating, when the ambient temperature is above 10 degrees, the heater automatically stop heating; when the humidity is lower than or equal to 75RH%, heater stop heating. When the ambient temperature is greater than 40 degrees, the system is forced to stop heating, heat exhaust lights, fans began to work, when the temperature is below 35 degrees fan stops working. Manual heating switch: auto or manual switch can be in two states, usually in the automatic mode, when temperature and humidity control logic above, when you press the switch, then manually force in a heated state 4, smart anti-error prompts (choice. equipped) When the circuit breaker is in the test position between the working position, when the circuit breaker is in closing state, a "sub-circuit breakers," the voice prompts until the circuit breaker after the operation ended, in order to prevent the operator When the circuit breaker is closed, the error Used to promote the work position. When the circuit breaker is in the working position or test position, the circuit breaker is closing another state, if the error is forced to switch on grounding switch, the "please point grounding switch," the voice prompts, the operator until after the opening operation is stopped to This prevent the operator closing earthing switch. When these two conditions occur simultaneously, the "sub-circuit breakers, please point grounding switch," the voice prompts. 5, the communication function (optional) The device has RS485 communication interface, can be transmitted in real time location status handcart, breaker position status, the spring energy storage state, grounding switch status, low-temperature heating, is overheating alarm and a series of parameters. 6, the other auxiliary functions The device panel, the matching requirement specified by the user points / closing million transfer switches, remote / local million transfer switches, storage and cabinet lighting switches, the user can be related directly onto the unit operation. 2. Schemes (Pictured standard used concrete follow-kind prevail.) 1. Installation: panel mounting (thickness) of the unit: 70 mm installation hole size 230 120 220 3. Dimensions of the sensor 45 37 2-φ4 with screws in the appropriate cabinet position can bring their own guides 35 mm installation and wiring 21 Service 1, the company sold products commitment: one year warranty and lifetime maintenance; 2, starting from the date of sale of products, In the one-year warranty period, belong to non-human causes damage to the product, our repair replacement; otherwise belong to paid services; 3, more than the warranty period, is a paid service. Switchgear intelligent control device when the warning (1) Unplug the device pressure to play all terminals, such as the misuse of our company will be paid services! (2) high pressure experiments show that if the experiment using the regulator, make sure the voltage regulator should not exceed 12. AC V (3) This product is a smart device, which has anti-jamming system to automatically reset function, while the design of POST functions, including software parameters and output relays self-test, in line with EMC / 14598 relevant technical standards. GBT cabinet wiring please pay attention to try the secondary signal sensor cables and communication cables away from noise sources (such as energy storage inductors and other large equipment), in order to avoid the introduction of magnetic interference, affect the system work properly. If the interference is instantaneous and the impact to the system, then installation will start automatically reset function, if the interference is continuous, then the device will continue to monitor the system status, and start the reset function, until the interference disappears, the system can lift the automatic recovery feature. HYD-5600 Installation Guide, before using the product, please read this manual This manual Please Reserved
Contact Detail
Company Name: | Gas Equipment Co., Ltd. Shenzhen Norhill |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Yan Chaoli() |
Telephone Number: | 0755-27048182 |
Company Address: | Longhua Town, Shenzhen City, Guangdong, China |
Zip/Postal Code: |
Find More Related Products
- Outdoor rain me
- Wholesale oil outdoor high-..
- Lighting distribution box
- Texas high-voltage switchge..
- Texas High-voltage switchge..
- Texas high-voltage equipment
- Professional production Swi..
- High pressure RMU
- xl21 power cabinet
- GGD AC low-voltage switchge..
- GCK withdrawable switchgear
- HZW32-12 outdoor high-volta..
- Supply ZW32-12T vacuum circ..
- MV switchgear cabinet
- Shennong Herbs paste precau..
- Shipping kebab machine Guan..
- Capacity transformer, the t..
- Capacity transformer factor..
- Three-phase distribution tr..
- Supply vacuum circuit break..