Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Beijing Yuasa Battery NP100-12 agents

Beijing Yuasa Battery NP100-12 agents
Beijing Yuasa Battery NP100-12 agents
Beijing Yuasa Battery NP100-12 agents

Larger photo of automa dispenser

Company:Pendleton Beijing Electronic Science and Technology Co...
Information Name: Beijing Yuasa Battery NP100-12 agents
Update Time:2015-04-29
Validity:360
Specifications:407 * 172 * 240
Quantity:1.00
Price Description: RMB/
Inquire Now
The Acting Company: Vincent batteries | sunshine battery | Germany sunshine battery | USA BB Battery | GNB Battery | RGB batteries | Hawk batteries | Hoppecke batteries | sea-batteries | Merlin batteries | San Yang batteries | Auto batteries | Dorset Battery | otp battery | Panasonic batteries | Hercules batteries | Champions batteries | Ou Musi batteries | Yuasa Battery | Battery Ellis | Saida batteries | Race to Battery | Battery camel | AST batteries | Lion batteries | Eagle batteries | Snipes batteries | Su Keshi batteries | Xing Yue batteries | batteries Hills | Hills UPS power supply | MGE UPS power supply | Emerson UPS | Eaton ups power | SENDON ups power | Delta ups supply | APC-ups Power | Reynolds ups power batteries and other model series, ups power spot nationwide: [North], Beijing, Tianjin, Hebei Province, Shanxi Province, Inner Mongolia Autonomous Region, Liaoning Province] [northeast Jilin, Heilongjiang, Zhejiang Province, Anhui Province, Jiangsu Province, Shanghai [EAST]?? Fujian, Shandong Province, Jiangxi Province? [CENTRAL] Henan, Hubei Province, Guangdong Province, Guangxi Zhuang Autonomous Region, Hunan Province Hainan? [southwest] Chongqing City, Sichuan Province, Guizhou Province, Yunnan Province Tibet Autonomous Region? [northwest] Ningxia Hui Autonomous Region, Shaanxi Province, Gansu Province, Qinghai Province Xinjiang Uygur Autonomous Region?] [Hong Kong, Macao and Taiwan Special Administrative Region and Macao Special Administrative Region, Taiwan Province of the company's marketing channels for mainland China, Hong Kong, Macao and Taiwan, the product quality is our pride, to provide customers with satisfactory service is the standard of our work! Welcome customers to call: 24-hour telephone: 15301391792- Yang Tong Technical support: 15301391792 Yang Tong QQ: 1758797949 Tel: 010-56103336 Our commitment: All products year replacement, three-year warranty, regardless of the quantity you order more or less the company will send professional engineers on-site installation design, (engineer all costs borne by the company) Our aim:??????????????? the pursuit of excellence, customer first, service first? ??????????????????????????????? Our management philosophy: human, institutional, scientific and international??? ????????????????????????????? Our philosophy: to advanced technology services to customers - to create value, and create a win-win??? ????????????????????????????? Our service philosophy: all to customer growth as the fundamental????????? ??????????????????????? Our style: passion, unity, integrity, win-win, dedication, responsibility?????????? ?????????????????????? Our market concept:? The customer suggestions and comments as a topic of study and research of Notes Yuasa Battery use * Different ﹑ ﹑ different types of different brands in different newness of the capacity, the battery generally can not be mixed, otherwise they will not match and pull the bad battery. * Battery is 100% charged the factory, to be careful to avoid short circuit; installation should use insulated tools, wear insulated gloves to prevent short circuits and electric shock. * Install the battery by a qualified technician to implement, when a plurality of batteries connected in series, the positive and the other negative battery should be linked to a cell, and so forth the composition of the battery pack, then the positive electrode of the battery pack again UPS is connected to the positive (red for positive), a negative electrode of the battery pack connected to the UPS (black for negative), and proper firmly. Polarity connection error, it can cause damage to the battery or machine. * For the initial use, the battery shall be fully charged before use, if not sufficiently charged can cause its performance can not play; if long-term use, the battery will self-discharge gradually reduce its capacity, it is recommended every three months charge it . * The use of batteries away from organic solvent, well-ventilated, dry, cleanliness, the longest life at 5 ℃ -35 ℃ of environment. * Should try to avoid battery discharge, the UPS is done and should be closed after the UPS power switch, and charged immediately after utility power is restored, otherwise it will cause deterioration of battery performance. Yuasa Battery NP100-12 battery design life: 24Ah following five years, 24Ah over 6 years (24Ah). Model Voltage (V) Capacity (Ah) Reference Dimensions (mm) Weight (kg)? Length and width total height? NP1-6? 6? 1.0 (20 hour rate)? 51? 42.5? 54? 0.25 NP4-6? 6 ? 4.0 (20 hour rate)? 70? 47? 105? 0.85 NP10-6? 6? 10 (20 hour rate)? 151? 50? 97.5? 2 NP0.8-12? 12? 0.8 (20 hour rate)? 96? 25? 61.5? 0.35 NP1.2-12? 12? 1.2 (20 hour rate)? 97? 47.5? 54? 0.57 NP2-12? 12? 2.0 (20 hour rate)? 150? 20? 89? 0.7 NP2 .3-12? 12? 2.3 (20 hour rate)? 178? 34? 64? 0.94 NP2.6-12? 12? 2.6 (20 hour rate)? 134? 67? 64? 1.12 NP7-12? 12? 7 (20 hour rate)? 151? 65? 97.5? 2.65 NP24-12? 12? 24 (20-hour rate)? 175? 166? 125? 8.65 NP38-12? 12? 38 (20 hour rate)? 197? 165? ? 170 13.8 NP65-12 12 65 (20 hour rate) 350 166 174 22.8 NP100-12 12 100 (20 hour rate) 407 172.5 240 35 Yuasa Battery care and maintenance????????????: UPS power supply system in use in the process, people often one-sided that the battery is maintenance-free and not take this seriously. However, our data show that the proportion due to battery failure caused by a host failure or UPS is not working properly is about 1/3. Thus, strengthening the proper use and maintenance of the UPS battery to extend battery life and reduce UPS power supply system failure rate, with more and more important. In addition to an optional battery other than regular brands, the following aspects should properly use and maintain the batteries: 1. To maintain the appropriate environmental temperature. Important factors that affect battery life is ambient temperature, ambient temperature is usually the best battery manufacturers claim is between 20 ℃ ~ 25 ℃. Although the temperature rise of the battery discharge capacity has increased, but the cost is greatly reduced battery life. According to tests measuring the ambient temperature once more than 25 ℃, each increased 10 ℃, the battery life would be shortened by half. UPS batteries currently used are generally VRLA batteries, universal design life of five years, which can be achieved at battery manufacturer demanding environments. Less than the required environmental requirements, there is a great difference in the length of its life. In addition, the increase in ambient temperature can cause the battery internal chemical activity increased, resulting in a lot of heat, in turn prompting the ambient temperature, this vicious cycle will accelerate shorten battery life. 2. Regularly charge and discharge. UPS power supply system in the float voltage and discharge voltage at the factory have been commissioning rating, and discharge size is increasing as the load increases, the use should be reasonable to adjust the load, such as a control computer and other electronic equipment Use several. In general, the load should not exceed 60% UPS rated load. Within this range, the battery will not over-discharge. UPS connected to the mains due to long-term, high-quality power supply, power outages are rare use of the environment, the battery will be a long period of floating charge state, a long time will cause the battery chemical energy and electrical energy into each activity decreased, accelerated aging shorten life. Thus, generally every two to three months should be fully discharged once, discharge time can be determined based on the battery capacity and load size. After a full load discharge is complete, according to the provisions recharge more than 8 hours. 
Contact Detail
Company Name: Pendleton Beijing Electronic Science and Technology Co...
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Yang Tong(Manager)
Telephone Number: 010-56103336
Company Address: Haidian District, Beijing, Beijing, China
Zip/Postal Code: 100000
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450