Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Yellowstone expansion tank

Yellowstone expansion tank
Yellowstone expansion tank
Yellowstone expansion tank

Larger photo of automa dispenser

Company:Ming Fung Ltd. Wuhan far
Information Name: Yellowstone expansion tank
Update Time:2015-04-29
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Yellowstone expansion tank, expansion tank factory Yellowstone, Yellowstone expansion tank prices, wholesale expansion tank Yellowstone, Yellowstone retail expansion tank - Wuhan far Ming Fung provides expansion tank is widely used in air conditioning, solar, boilers and other HVAC systems and water and fire-fighting equipment, buffer system pressure fluctuations. Good buy expansion tank, buy quality expansion tank, consult a professional to do the expansion tank of Wuhan far Ming Fung Technology, Wuhan far Ming Fung Ltd. located in nine provinces of Wuhan City, Hubei Province, the national wholesale expansion tank and homemade Italian VAREM expansion tank , complete specifications, 2-3000L expansion tank perennial with large inventories, the air-conditioning manufacturers, solar companies, boiler plant long-term partners, while providing accessories safety valve, automatic water valve, automatic exhaust valve can be used with supporting the expansion tank We not only sell the expansion tank, can also solve your expansion tank expansion tank is mounted to the selection of a series of questions, is your ideal one-stop sourcing platform, buy the expansion tank looking Wuhan far Ming Fung. Expansion tank role: the role of general expansion tank pressure fluctuation buffering system, not the system pressure rises too fast to make the system pressure drop is not too Meng, let the system at a relatively steady pressure to run, but in the closed cycle system and water supply system which is not exactly the same role in the air conditioning, solar, boiler, floor heating and other closed-loop system, the role of the expansion tank expansion tank is to absorb the amount of volume expansion of the working medium temperature increases, the prevention of system pressure increases too quickly, reduce the liquid in the working temperature of the medium within the balloon released volume contraction, adding to the system, not the system pressure drop over Meng, reducing the number of pressure relief valve and a number of automatic water replenishment valve; in frequency water supply, pressure water and fire water supply system, a major role in the expansion tank is the buffer pump start and stop, and system valves open and close the water hammer produced when, to prevent water hammer damage components on the piping and systems, as well as in water low peak pump to ensure adequate sleep time, not only saving but also to extend the life of the pump. Expansion tank types: expansion tank according to the structure can be divided into bladder-type expansion tank and diaphragm expansion tank, the difference lies in the bladder-type expansion tank when the water does not work in contact with the tank wall, long life, and diaphragm expansion tank work tank Usually the body wall almost directly with the water contact, easy to rust failure and cause secondary pollution of water, due to the above disadvantages, diaphragm expansion tank is currently phasing out of the market; the expansion tank can be classified according to the material of carbon steel and stainless steel expansion expansion tank cans, steel expansion tank bladder-type structure can meet the requirements of the vast majority of the system, but in the field of food and other special stainless steel expansion tank must be used; expansion tank by the pressure resistance is usually divided into 6bar, 8bar, 10bar, 16bar and 25bar five kinds of pressure, the higher the pressure of the occasion, such as a hydraulic accumulator system to use more of, 6bar 8bar expansion tank and meet most of the requirements of the HVAC system, 10bar, 16bar and 25bar expansion tank used for water supply and fire protection systems , pressure resistance depends on the expansion tank and the tank wall thickness of the balloon wall thickness, under the same conditions, the thickness, the higher pressure; expansion tank can be divided by the heat resistance temperature of 70 degrees, the temperature of 100 degrees and three temperature 130 degrees, the heat resistance of different materials varies airbag, general water supply equipment medium temperature is normal, the temperature 70 degrees in the expansion tank is sufficient to use air conditioning, boiler and heating system in general temperature of 100 degrees Nine expansion tank to meet the requirements, but in the solar system, in particular pressure solar system under the summer sun nausea, medium temperature exceeds 100 degrees, this time we should use 130-degree temperature of the expansion tank; 
Contact Detail
Company Name: Ming Fung Ltd. Wuhan far
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Zhang lofty(Operations)
Telephone Number: 027-87467738
Company Address: Meishu room Xiongchu 459 Sunshine Road 1803, Block A, , Hubei, China
Zip/Postal Code: 430070
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450