KS205D-Ⅰ Doppler phantoms and simulated blood flow control system
KS205D-Ⅰ Doppler phantoms and simulated blood flow control system
System Specifications 1. Doppler phantom housing transverse dimension: 200mm × (80 ~ 100) mm Depth: 170mm. 2. Acoustic window size: 70um × 200mm × (80 ~ 100) mm 3. Ultrasound tissue mimicking (TM) material velocity: (1540 ± 10) m / s (23 ℃) Attenuation: The standard set for (0.5 ± 0.05) dB / (cm · MHz) (23 ℃) (such as dedicated to the detection of the operating frequency At the high end or the low end of Doppler instrument, the choice of the attenuation coefficient of the material above or below the value of TM, especially customized 4. ultrasound vascular density imitation:. 0.930 (g / cm3) Material Velocity: 1555 (m / s) Material sound attenuation coefficient: frequency measurement varies with location, as shown in Table 1; diameter: standard sleeve for 8mm and 4mm, also in the range of 0.5 to 32mm chosen by a factor of 2 other sizes made subject to special ; wall thickness: standard sleeve wall thickness of the inner diameter of 8mm 1.6mm; 0.8mm internal diameter of the inner diameter of 4mm wall thickness change, thickness changed as shown in Table 2; the angle between the plane of the acoustic window: standard sleeve 30 ° (2 oblique sections), but also the choice of 45 ° and 60 °, subject to any special build. Table 2 imitation vessel diameter and wall thickness of the correspondence between the inner diameter (mm) 4 8 thickness (mm) 0.8 1.6 5. ultrasound imitation blood density : (1.03 ± 0.04) g / cm3 speed of sound: (1570 ± 30) m / s Attenuation: <0.1dB / (cm · MHz) backscatter: (1 ~ 10) × 10-9 × f4 / (cm · MHz4 · Sr) Viscosity: (4 ± 0.4) × 10-3Pa · s 6. current pump revolutions: 0.2 ~ 300RMP Number of heads: 1 or 2 chucking silicone rubber hose: wall thickness of 1.5mm, an inner diameter of 0.8,1.6 , 3.1,4.8,6.4,7.9mm optional flow range: 0.014 ~ 1140ml / min control switch: left / stop / right speed control: Adjustable potentiometer fluid via: only via pipeline supply: Voltage 220 ± 10% AC, frequency 50 ~ 60Hz Working environment: Temperature 0 ~ 45 ℃, relative humidity <80% 7. Controller (optional) pulse parameters: the width and interval were set minimum pulse width: 0.1s pulse minimum interval: 0.1s 8. Rotor The number of flow meter: 2, used in tandem Range: 1 ~ 10L / h (ie 0.278ml / s ~ 2.78ml / s) 6 ~ 60L / h 9. imitation (ie 1. 67ml / s ~ 16.7ml / s?) Blood Tank Capacity: 500ml; 10. buffer capacity: 500ml;
Contact Detail
Company Name: | Nanjing-detection equipment Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Ge Yanming() |
Telephone Number: | 025-84855931 |
Company Address: | Nanjing, Nanjing, Jiangsu Province, China |
Zip/Postal Code: |
Find More Related Products
- Jack test device
- CC2674-3 type pressure test..
- CC2679 type insulation resi..
- CC2681 type insulation resi..
- CC2680 type insulation resi..
- CC2672E type programmable v..
- Xiaoshan to Baotou logistic..
- Hefei miniature autoclave p..
- CC2521E type Medical Ground..
- NDJ-3 current detector leak..
- PZV-2 megameter end voltage..
- E1E2F1F2M1M2 stainless stee..
- KC Series Caliper Gage
- South Million and is teachi..
- Beijing xenon lamp aging ch..
- Shenzhen measuring instrume..
- Milliwatt ultrasonic power ..
- WJ2072 enhanced intelligent..
- B-test device (two phantom)
- B-test simulated tissue pha..
- Forum -RoHS supply ROHS Chi..