Injection headspace GC-MS
Injection headspace GC-MS
|
Agilent7890A + 5975C 1. Operating Conditions 1.1 Power: 220V, 50Hz 1.2 Temperature: Operating Environment 15 C-35 C 1.3 Humidity:?? Operating state 25-50%, 10-95% non-operating state 2. Performance Indicators 2.1 Gas Chromatograph 2.1.1 Operation 2.1.1.1 oven temperature: room temperature above 4 C-450 C 2.1.1.2 Temperature resolution:??? 1 C temperature setting, 0.1 C 2.1.1.3 programmed maximum heating rate:? 120 C /? 2.1.1.4 minutes maximum running time: 999.99 minutes * 2.1.1.5 20 order / 21 platform programmed temperature 2.1.1.6 Temperature stability: <0.01 C per 1 in C environment 2.1.1.7 Temperature accuracy:?? ≤0.01 C *? 2.1.1.8 Cooling rate:? from 450 C to 50 (at 22 ℃ ambient temperature) C <240 秒 * 2.1.1.9 retention time reproducibility: 0.008% or <0.0008min * 2.1.1.10 peak area repeatability : <1.0% RSD 2.1.2 capillary split / splitless (with electronic pneumatics control, referred to as EPC) * 2 2.1.2.1 maximum operating temperature:? 400 C 2.1.2.2 Electronic parameter set pressure, flow rate and The split ratio * 2.1.2.3 Pressure Range: 0-150Psi, precision 0.001Psi 2.1.2.4 Flow Range: 0-200mL / min N2, 0-1250mL / minH2 or He 2.1.2.5 Split ratio: 7500: 1, to avoid chromatography Column overload 2.1.3 FID (FID) 2.1.3.1 maximum operating temperature: 450 ℃; 2.1.3.2 Automatic ignition device with automatic fire detection; * 2.1.3.3 detection limit: <1.8pg carbon / sec ( propane); * 2.1.3.4 sample acquisition rate: 500Hz; * 2.1.3.5 linear dynamic range: ≥107; 2.1.4 automatic temperature control system 2.1.4.1 switching valve six-cylinder injection valve: Number 1; * 2.1.4.1 Time series can be switched automatically; * 2.1.4.1 valve box maximum Temperature range: 225 ℃; 2.2 mass detector 2.2.1 has a network communication function, which enables remote operation 2.2.2 Side panel, the panel controller Mass compact display status information and mass input 2.2.3 Structure of operating parameters, without cooling water and compressed air cooling * 2.2.4 mass range: 1.6-1050amu, to 0.1amu increments 2.2.5 Resolution: 2.2 unit mass resolution .6 mass axis stability: better than 0.10amu / 48 hours * 2.2.7 :( sensitivity with capillary column HP-5MS 30mx0.25mmx0.25um measurement) full scan sensitivity (electron bombardment source EI): 1pg Octafluoronaphthalene (OFN ), the signal / noise ratio ≥400: (scanning range: 50-300amu) selected ion monitoring (electron impact source EI): 20fg Octafluoronaphthalene, signal / noise ratio ≥10: 1 2.2.8 Maximum scan rate: 12500 amu / s 2.2.9 Dynamic Range: Full dynamic range is 106 * 2.2.10 selected ion mode detection (SIM) can have up to 100 groups can select up to 60 ion * 2.2.11 Mass workstation based on the data obtained by full scan automatically select the characteristics of the target compound ions and group, and finally save the analysis methods, the need for manual input. (AutoSIM) * 2.2.12 with a full scan / selected ion monitoring while collecting function * 2.2.13 with two long-term efficient electronic bombardment source filament, a completely inert material * 2.2.14 ionization energy: 5 ? -241.5eV * 2.2.15 ion source temperature: independent temperature control, 150-350 C adjustable * 2.2.16 AUTOMATION source: mass spectrometer equipped with special chemical source tuning compound (EI source with a different tuning of the compound); n, tuning and the reaction gas flow negative chemical ionization mass spectrometry workstation is fully under control * 2.2.17 Analyzer: whole gold-plated hyperbolic quadrupole, individual climate control, 106 C - 200 C * 2.2.18 Detector:? triaxial long? efficient high energy electron multiplier * 2.2.19 Vacuum system: turbo pump (70 l / s), 2.5m3 / min mechanical pumps * 2.2.20 temperament Interface Temperature: independent temperature control, 100-350 ℃ 2.2.21 with early Maintenance Forecasting function (EMF) 2.2.22 provides quality authentication function (OQ / PV)
Contact Detail
Company Name: | Quanzhou Smith Barney Instrument Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Su Jinhua(Sales Manager) |
Telephone Number: | 0595-68900281 |
Company Address: | Quanzhou, Fujian Nanan County National Science Park, Quanzhou City, Fujian Province, China |
Zip/Postal Code: | 362000 |
Find More Related Products
- Cheng Ding-precision second..
- Cooker glass color glass co..
- Japan SONY optical device
- CC5100 days Woori camera te..
- TILO days Woori standard li..
- Injector color detection sp..
- Tank inspection
- Ink color ink color ink col..
- Precision colorimeter preci..
- Enhanced ISO12233 test card..
- Resolution card resolution ..
- Color boxes boxes TILO days..
- Zhongshan colorimeter color..
- Dongguan colorimeter Color ..
- Color detection equipment
- Shenzhen colorimeter colori..
- Foshan colorimeter colorime..
- Huizhou colorimeter color q..
- Jiangmen colorimeter colori..
- Zhuhai colorimeter color me..
- DRTG-81 light transmittance..