Home
Products
JSD low-frequency rubber shock absorber applied to air conditioning system noise control studio
JSD low-frequency rubber shock absorber applied to air conditioning system noise control studio
JSD low-frequency rubber shock absorber applied to air conditioning system noise control studio
JSD low-frequency rubber shock absorber applied to air conditioning system noise control studio JSD JSD low-frequency low-frequency composite rubber shock absorber rubber shock absorber is made of metal and rubber composite, all clad rubber surface to prevent metal corrosion. Rated load for the domestic natural frequency of various types of rubber shock absorber lowest for pumps, compressors, fans, chillers, air compressors and other power machinery on the basis of vibration and noise reduction, especially for vertical pumps Vibration basis. And other frequency is good, when more than the rated load, the natural frequency of the damper remains unchanged. Damping ratio, the stronger its ability to inhibit Zhenfeng. Simple structure, easy to install, can be installed directly in the base, but can also be the foundation bolts to install, safe and reliable. Load range of 30kg-3000kg. Oil, water, salt, fog and sunshine for temperature -25 ℃ ~ + 80 ℃. JSD-type technical parameters and dimensions table Model Rated load static deformation natural frequency damping ratio MD D1 H hdn (kg) (mm) (Hz) (C / Cc) (mm) (mm) (mm) (mm) (mm) (mm) JSD-30 15 ~ 30 5 ~ 12 5 ~ 7.5> 0.7 12 150 120 55 9 12 4 JSD-50 30 ~ 50 5 ~ 12 5 ~ 7.5> 0.7 12 150 120 55 9 12 4 JSD-85 50 ~ 85 5 ~ 12 5 ~ 7.5> 0.7 14 200 170 75 9 12 4 JSD-120 85 ~ 120 5 ~ 12 5 ~ 7.5> 0.7 14 200 170 75 9 12 4 JSD-150 110 ~ 150 5 ~ 12 5 ~ 7.5> 0.7 16 200 170 85 9 14 4 JSD-210 130 ~ 210 5 ~ 12 5 ~ 7.5> 0.7 16 200 170 85 9 14 4 JSD-330 210 ~ 330 5 ~ 12 5 ~ 7.5> 0.7 18 200 170 90 9 16 4 JSD-530 330 ~ 530 5 ~ 15 5 ~ 7.5> 0.7 18 200 170 90 9 16 4 JSD-650 530 ~ 650 5 ~ 15 5 ~ 7.5> 0.7 20 200 170 95 9 16 4 JSD-850 650 ~ 850 5 ~ 15 5 ~ 7.5> 0.7 20 200 170 95 9 16 4 JSD-1000 850 ~ 1000 5 ~ 15 5 ~ 7.5> 0.7 20 200 170 95 9 16 4 JSD-2000 1250 ~ 2000 5 ~ 18 5 ~ 7.5> 0.7 22 299 259 115 10 18 4 JSD-2500 1800 ~ 2500 5 ~ 18 5 ~ 7.5> 0.7 22 299 259 115 10 18 4 JSD-3000 2500 ~ 3000 5 ~ 18 5 ~ 7.5> 0.7 22 299 259 115 10 18 4 Suzhou Celeste Adams Shock Absorber Co., Ltd. Tel: 0512-68786858 Mobile: 18551266677 Company Website: www.sailaisi.com Address: Riverside Road, Suzhou New District 1701 Noise Control Method One: active noise reduction. Active noise reduction is the use of computer technology, based on the noise of the sampling frequency, amplitude, period, etc., and generates near synchronous inverted signal superimposed to achieve the purpose of noise control. Currently, this type of noise control method is not mature enough, in the research and development stage. Noise Control Method two: passive noise reduction. Most noise reduction methods are passive noise reduction. In accordance with the use of materials and parts can be divided into vibration noise control, acoustic noise control and soundproofing noise control. In most cases, a variety of methods are usually combined use. According to the current material technology and construction techniques, basic can control any noise. Beijing Branch source of sound noise control engineering and technology Equipment Co., Ltd. adopt measures to control the sound output noise source, the control of noise propagation and reception, to give it the desired acoustic environment, namely noise control. Using a variety of noise control methods can receive different noise reduction. As ordinary gear mechanical transmission parts changed elastic sleeve gear, it can reduce noise 15 to 20 db; caulking into welding, forging into the friction pressure processing, generally 30 to 40 db noise reduction. Select control measures and reasonable measures to control noise is based on the cost of noise control and noise standards to allow the relevant factors, labor productivity such as a comprehensive analysis determined. Control of environmental noise control technology is the basic means. Administrative measures and proper planning are also very important. Noise control technology basically all of the noise problem can be divided into three parts: source - transmission - receiver. Thus, the general noise control techniques are divided into three parts to consider. The first is to reduce the sound source of the noise, if you can not do, or can do but not the economy, is considered to reduce the spread pathway. As the above scheme still meet the requirements of noise control or uneconomical may consider the recipient's personal protection. (1) sound source control reduces noise source itself is the ultimate solution; (2) the transmission of noise control; (3) the absorption: the main use of sound-absorbing material or absorbent structure to absorb acoustic energy; (4) Noise: with sound shield block, isolate, is one of the most effective measures to control the noise; (5) muffler: muffler is the use of mufflers to reduce the spread of sound in air.
Contact Detail
Company Name: | Shock Absorber Co., Ltd. Suzhou Seles |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Lu Dong() |
Telephone Number: | 0512-68786858 |
Company Address: | Suzhou, Suzhou , Jiangsu Province, China |
Zip/Postal Code: |
Find More Related Products
- ZDG type spring shock absor..
- SG type viscous damping iso..
- Boiler room noise quality S..
- Pump noise control project ..
- Ventilation ducts Noise Con..
- Antique brick factory in Si..
- Yichang oil-free screw comp..
- Professional production of ..
- Supply chip conveyor
- Gravity means prices
- Hengxing Heavy Figure whole..
- Compound pendulum jaw crush..
- Factory direct chip conveyo..
- Glamorous ice painting: hig..
- CNC lathe serves Indian ACE..
- Recovery refrigeration equi..
- Japan's Mitsubishi Heavy In..
- Hitachi, Japan imported 10 ..
- Japan imported JT335 Daikin..
- Conveyor production and par..
- Stone computer engraving ma..