Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Self-priming pump, XBD-ZW horizontal self-priming fire pump, single-stage self-priming fire pump

Self-priming pump, XBD-ZW horizontal self-priming fire pump, single-stage self-priming fire pump
Self-priming pump, XBD-ZW horizontal self-priming fire pump, single-stage self-priming fire pump
Self-priming pump, XBD-ZW horizontal self-priming fire pump, single-stage self-priming fire pump

Larger photo of automa dispenser

Company:Yongjia County Aobang Pump Manufacturing Co.
Information Name: Self-priming pump, XBD-ZW horizontal self-priming fire pump, single-stage self-priming fire pump
Update Time:2015-04-29
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Self-priming fire pump Description: self-priming fire pump is based on the different requirements of the provisions of the Fire Code and all types of users, their own research and development from the electromechanical equipment. Products with innovative, advanced, practical, simplified design of the pump room, pump room on the ground floor can be changed to facilitate the construction, saving investment; self-priming fire pump features: Pump compact structure, small size, beautiful appearance, it stands formula, decided small mounting area, its center of gravity coincides with the pump foot center, thereby enhancing operational stability and life of the pump. Self-priming fire pump Use: Self-priming fire pump for high-rise buildings, hotels, commercial buildings, all kinds of buildings, subway, light rail, train stations, industrial and mining enterprises and other important sectors of fire safety requirements, it is not only for the sprinkler system hydrant system water supply facilities, can also be widely used in domestic water supply systems. Fire pump is self-priming conditions: 1. Ambient temperature ≤45 ℃, medium temperature ≤60 ℃. 2. Media PH value 6 to 9 iron pump, stainless steel pump 1 to 14. 3. Through the particle diameter is 60% of the pump diameter, the fiber length of 5 times the diameter. 4. The total weight of impurities in the medium does not exceed 15% of the total weight of the medium, not medium weight over 1240 kg / cubic meter. XBD fire pump is self-priming according to the different requirements of the provisions of the Fire Code and all types of users, from their own research and development of electromechanical integration equipment: Details self-priming fire pump. Products with innovative, advanced, practical, simplified design of the pump room, pump room on the ground floor can be changed to facilitate the construction, saving investment; can take advantage of the outdoor pool to achieve the same requirements; the use of self-absorption feature can be the fire water so deep to 6m, so effective in the same volume, the land area occupied by the pool is much smaller than the original, thus saving space, easy construction, reduce costs, but also greatly save investment; can operate at negative level, and timely to meet the fire safety requirements ; self-priming fire pump water timely, timely disaster relief fire; with strict and reliable automatic polling function, the unit usually in quasi-fire state, once the immediate water needs to be able to enter the fire condition. Self-priming fire pump Features: 1, the pump body compact, small size, beautiful appearance, its vertical organization decided to install a small area, its center of gravity coincides with the pump foot center, thereby enhancing operational stability and life of the pump. 2, fire pump intake and outlet in the horizontal direction, simplifying the piping connections. 3, according to need, inlet and outlet may be mounted in the same direction or 90 °, 180 °, 270 ° in several different directions to meet different connection situations. 4, pump pressure pump series can be adjusted according to needs and cutting impeller diameter to be met without changing the installation footprint, which is the other pumps that do not have. 5, fire pump rotor has a smaller degree around, smooth running, small vibration, low noise, long life. 〖Self-priming fire pump uses]: self-priming fire pump for high-rise buildings, hotels, commercial buildings, all kinds of buildings, subway, light rail, train stations, industrial and mining enterprises and other important sectors of fire safety requirements, it is not only for spray shower systems, fire hydrant system, water supply facilities, can also be widely used in the domestic water supply system. Installation requirements: 1, before installing the pump abortion should be carefully examined whether the hard object, so as not to damage the impeller and the pump running. 2, the installation of piping reasonable amount shall not be allowed on the pump, so as not to pump deformation, affecting the normal operation. 3, tighten the bolt, so as not to affect the performance of the pump vibration when starting. 4, in the inlet and outlet piping of the pump control valve installed in the vicinity of the pump outlet mounting pressure gauge to control the pump operates within its rated operating conditions, ensure the normal use of the pump. 5, the discharge pipe loaded check valve should be installed outside the gate. 6, the installation of the pump into a rigid connection to install and flexible connection installed. 
Contact Detail
Company Name: Yongjia County Aobang Pump Manufacturing Co.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Xiong Feng in(Sales Manager)
Telephone Number: 0577-67965097
Company Address: Ou Yongjia County streets and three villages, , Zhejiang, China
Zip/Postal Code: 325105
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450