Product Overview automatic reclosing leakage protection is the use of machinery automation principles, combined with high-voltage automatic recloser controller technology developed for intelligent products. It can be solved due to transient faults caused by tripping the switch does not automatically restore power outage problems, but also through the voltage, current, leakage and other real-time monitoring the operation of power lines and electrical equipment lines for opening protection. It provides a stable and reliable power supply for the electrical equipment, thus extending the life of electrical equipment, improve network service quality, reduce network maintenance costs. The product is suitable for AC 50HZ or 60HZ, rated current less than 63A single-phase mains wires. When Line leakage, overcurrent, short circuit, over-voltage and low-voltage failure, automatic reclosing protection can be quickly cut off the supply line, failure to eliminate automatic reclosing after transmission, without manual closing, to ensure electrical equipment and line-powered security and sustainability. Products can solve problems due to lightning lightning, socket transient faults caused by arcing, etc. cause tripping the switch does not automatically restore power supply, but also by the voltage, current, leakage and other real-time monitoring of the operation of the power supply line for electrical equipment and lines for opening protection. This product complies with: General requirements 1.GB6829-1995 residual current operated protective devices 2.GB16917.1-2003 household and similar uses overcurrent protection for residual current operated circuit breaker (RCBO) Lightning protection features ?? multi-level protection device can reduce the chance of damage and prolong the life of the user equipment? detected before closing, to avoid secondary coincidence power to the failure of equipment damage, protect the power supply environment safe? compensation regulator output, efficiency above 90% for the AC85V-AC300V voltage variation between the worst case? products using rail mounting, easy installation and maintenance, fault dry contact output can monitor fault information through the? perfect over-current, overvoltage, undervoltage, leakage, short circuit protection, and ensure use electrical environment, equipment and personal safety by mechanical switching characteristics and automatic recloser controller technology combine to guarantee stable and reliable, very low failure rate? accurately and quickly identify the isolate permanent fault, transient fault exclusion, rapid self-healing power, protect the network is operating normally Technical Specifications Model Item JPJ-AR-6A JPJ-AR-10A JPJ-AR-16A JPJ-AR-32A JPJ-AR-63A Operating Voltage (VAC) 85 ~ 300 85 ~ 300 85 ~ 300 85 to 300 85 to 300 Rated load current (A) 6 10 16 32 63 over-flow for the current (A) 6 10 16 32 63 over-flow for the period (s) 2 2 2 2 2 short-circuit operating current (A) 25 50 50 50100 Short circuit operation time (ms) 30 leakage current (mA) 30 can be adjusted No leakage current (mA) 15 may be adjusted according to customer demand residual operating time (ms) according to customer needs 30 Overvoltage operating voltage (V) 270 ± 10V operating voltage can be adjusted voltage (V) according to customer demand 100 ± 10V over voltage operation time (ms) <100 closing Allowable load impedance (Ω)> 5 reclose interval 1 (s) 30 can be adjusted according to customer demand reclosing interval 2 (m) 30 reclosing interval can be adjusted 3 (h) can be adjusted according to customer demand a reclosing the reset time (s) 5 permanent fault isolation (blocking) Optional fault dry contact output √ according to customer demand Optional lightning protection √ regulated output power (W) <1 Operating Temperature (℃) -40 ~ 85 Indoor Outdoor Storage temperature -40 ~ 85 (℃) -20 ~ 55 Relative humidity (%) 10% 90% of the installation dimensions (mm) Indoor 90L * 98W * 66H outdoor type 152L * 116W * 98H indoor mounting rail card installed hold outdoor installation leakage protection Description The main function short circuit protection - line short circuit, if sustained 0.5 second, it will cause the line burned. If, within 0.1 seconds can be quickly cut off the power supply to avoid accidents. Automatic reclosing leakage protection in current is greater than 5 times the rated current (50 A or more), it is within .03 seconds off, to ensure the safety of leakage protection device - line personal electric shock or leakage occurs, the automatic reclosing leakage protection within .03 seconds off, to ensure the personal safety protection - If the line is overloaded, wires severe fever, is likely to cause a fire. When the current is greater than 1.1 times the rated current (11 amps), automatic reclosing leakage protection will monitor the duration and magnitude of this current; If during the duration of more than two seconds, or more than 50 security, automatic reclosing leakage protection will break electric implementation of protection over voltage protection - voltage is too high, the device is easy to burn, when the supply voltage is above 280 volts, automatic reclosing leakage protection power protection. When the voltage drops back to normal, automatic reclosing leakage protection automatically switch on power. Although the risk of high voltage, low voltage can easily lead to a fire, when the supply voltage drops below 100 volts, automatic reclosing power protection protector; voltage rises to normal after the automatic reclosing protection automatically switch on power-call delay co / de-energized opening - when the mains power failure, automatically disconnects the input and output lines, to avoid the re-call, since the peak or transient voltage is not normal, leading to the occurrence of the equipment being burned. When the electricity again calls should delay closing, due to the unstable power supply leads to the master device reboot frequently detected before closing - automatic reclosing leakage protection before the closing of the circuit to detect if there is a short circuit or severe leakage when the case will no longer closing and latching alarm; user if not repaired in time, without the exclusion of the fault, you can not switch on power-reclosing - the line fails, automatic reclosing protection immediately disconnected; After the fault is cleared, if the line is still safe, automatic reclosing protection device will automatically re-closing power. For permanent failure after three consecutive reclosing / eight unsuccessful automatic reclosing protection will not reclose lockout and alarm. For the concept of fault alarm reclosing frequency transient fault does not exist - the protective disconnected while different red light, indicating that the corresponding fault type fault dry contact - when failure protection, dry node conduction; normal output power When dry node disconnected. Monitor collector node judges powered by dry conditions RS232 communication port - automatic reclosing via RS232 port can be uploaded in real time the state and receive data 
Contact Detail
Company Name: Guangzhou Ji Pujia Electronic Technology Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Miss Lin(Sales Sales)
Telephone Number: 020-28309187
Company Address: The 9th North New Road, Guangzhou Tianhe District, Jubei Dagang Industrial Zone, Guangzhou, Guangdong, China