Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Running mechanical and electrical circuit board repair

Running mechanical and electrical circuit board repair
Running mechanical and electrical circuit board repair
Running mechanical and electrical circuit board repair

Larger photo of automa dispenser

Company:Shenzhen Great-Electronic Technology Development Depart..
Information Name: Running mechanical and electrical circuit board repair
Update Time:2015-04-29
Validity:99999
Specifications:
Quantity:
Price Description: RMB/
Inquire Now
Professional SHSS treadmill maintenance for many years, experienced, skilled, and shorter repair times. Over the years the company has focused on various types of fitness equipment, maintenance services, expanding partnerships with well-known brand manufacturers of fitness equipment in order to give priority to introduce original parts and technical personnel finally have a complete line of accessories resources strong technical team and a wealth of brand maintenance experience. Maintenance of the brand: Domestic: good family, Omar, the stars, the Department of Health, Department of Cheung, Shu Hua, brother, Junxia, ??evergreen, new aristocracy, Shidi Fei, KPT, beautiful life, British Kray, British School Adams, British Klein and other brands treadmill maintenance. Imports; BH, Icahn, Orient, Omar, Precor, handed down, Greene, Fitness, Andean, Nautilus, Joe Hill, XYPEX, SHSS treadmill maintenance, time-Plough, Space Technogym, star Chi and other brand treadmill maintenance. SHSS Treadmill Maintenance: 1. Power controller failure, press the start button, immediately operate at high speed without stopping. Solution: Replace the controller. 2. energized normal display, buzzer normal, press the start button, the time window can be timed for 5 seconds, then the buzzer rang again about, but the treadmill is not running. Solution: Replace the controller. 3. Electronic table shows the normal buzzer normal, with fixed start running. Solution: Replace the controller. 4. After power-electronic table shows normal, start relay, running belt stop immediately move it slightly. Solution: Replace the controller. 5. powered electronic table shows normal, the relay does not pull, press Start running belt does not move. Solution: Replace the controller. 6. After starting the motor low-speed impact. Solution: Replace the controller. 7. electricity fuse blows, the power shorted. Solution: Replace the controller. SHSS treadmill motor repair Symptom 1. Start, stop, acceleration / deceleration is normal, but the load is low, idling normal, people can not work on a treadmill. Cause: The motor field loss. Solution: Replace the motor. 2. electronic form, controllers were normal, but there was no response after starting. Reason: Brush is not in place, stuck. Processing: Re-install or replace the brush. 3. After starting the motor automatically accelerated process ran laps with running 0.5-3 stop or running speed instability. Reason: serious brush wear. Solution: Replace the carbon brushes. 4. After the start, there is an abnormally large impact sound or noise in the motor. Cause: The motor damage. Solution: Replace the motor. 5. When energized, leakage protection trip, the motor leakage. Solution: Replace the motor. After three and turquoise treadmill maintenance of electronic table Fault 1. Power lamp does not light, buzzer sounding. Solution: Replace the header. 2. After displaying normal energized, starts normally, accelerating or decelerating ineffective. Solution: Replace the header. 3. The same after power strokes per digital light, buzzer does not ring, all buttons are ineffective. Solution: Replace the header. 4. Press the start button after power does not automatically run at the lowest speed, acceleration and deceleration does not work. Solution: Replace the header. 5. Start button, stop button normal, can accelerate not slow down: key bad or seven-core cable connection is bad. Solution: Replace the header. 6. The lack of digital strokes, work, digital control bad, but does not affect the normal operation. Solution: Replace the header. 7. Press the Start button, muzzle velocity can run, five seconds after the shutdown. Solution: Replace the header. 8. After starting, the speed display window displays a single kilometers, according to the acceleration and deceleration and speed direct unresponsive. Solution: Replace the header. 9. Start button, stop button properly, hand acceleration and deceleration invalid. Solution: Replace the header or replace hand deceleration switch. 10. When energized, the LED flashes regularly. Approach: to determine the safety switch is put away. To determine the safety switch put away, but digital still flashing laws. Replacing header. 11. energized not installed safety switch, LED is not blinking, press the start button machine run. Solution: Replace the meter motor belt adjustment (1) All electric treadmill before it leaves the factory has been adjusted by the motor belt, but after a period of time, there will be a pause in the use of the phenomenon, which is caused due to motor belt is too loose. a. (2) to determine the motor belt is too loose way: adjust the treadmill speed 1.5km / h, his hands firmly grasp the handrail, forced to move their feet with a hard stall run as the running belt and front rollers at the same time stopped, But after running loose with force and continue to operate, this phenomenon indicates that the motor belt is too loose, the user will stop feeling, so long-term use can reduce the motor belt life, should be adjusted. (3) Workaround: use a special tool to adjust the motor belt adjustment bolt clockwise circle, the user does not stop feeling so far. SHSS treadmill maintenance run with a deviation Adjustment: adjust the running belt should be carried out before all the treadmill factory and after installation, the deviation of the phenomenon may also occur after a period of time, cause of this phenomenon is due to the following aspects : (1) The host put uneven. (2) A user does not run with a center foot movement. (3) user feet uneven force. Human-caused deviation phenomenon, few return to normal idling rotation. For deviation phenomenon can not be automatically restored using random equipped with special tools to semi-circle units to gradually adjust the walking belt adjuster bolts. Such as running with a bias to the left, clockwise to adjust the adjustment bolt to the left or right side of the adjusting screw counterclockwise. Such as running with skewed to the right, clockwise to adjust the adjustment bolt on the right or the left adjustment bolt counterclockwise. Running with a deviation not covered by the warranty, major maintenance by the user. Deviation will seriously damage the running belt, we must promptly found and corrected. Running with tightness and adjustment of deviation: A semi-circle around the unit clockwise regulator adjuster. Running belt slack adjuster: running belt should be adjusted before all the treadmill factory and after installation, but may also occur after a period of use slack, the walking belt slack is not covered by the warranty, major maintenance by the user. Running belt is too loose, then put the foot when running, will have to run between the belt and the roller slippage, but too tight is not good, it may damage the motor, running belt and rollers and the like. Under normal circumstances, both sides can be lifted off the run with a running board 50-60mm appropriate. Analyzing lubricants reduce friction will cause dirty or run with / running board friction increases, may have motor control board damage. Too much friction has the following characteristics: (1) power-down state, with the pedal running with very laborious even tread does not move; (2) load-speed treadmill running, pull down the safety switch, the running belt immediately stopped completely; ( 3) friction increases, it may cause damage to the motor or control panel, shunt trip, fuses blowing. Lubrication Maintenance: treadmill after a period of time, we must use special lubricants for the running board / running belt lubricated, it is recommended: use of time less than three hours a week, six months Lubricate time 3-6 hours a week, for three months lubrication Use once a week longer than six hours, once a month is not excessive lubrication lubrication, the lubricant is not possible, remember: a reasonable lubrication is an important factor in improving the life of the treadmill! Running board and run with maintenance: 
Contact Detail
Company Name: Shenzhen Great-Electronic Technology Development Depart..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Hwang Jin-wide(Engineering Manager)
Telephone Number: 0755-13168751203 0755-28851958
Company Address: Shenzhen Pinghu Street, Pinghu Village Road, No. 62 Simon scare, Shenzhen City, Guangdong, China
Zip/Postal Code: 518111
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450