Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Beijing does not get angry cement mortar factory supply, construction program

Beijing does not get angry cement mortar factory supply, construction program
Beijing does not get angry cement mortar factory supply, construction program
Beijing does not get angry cement mortar factory supply, construction program

Larger photo of automa dispenser

Company:Beijing Shun Jian Industrial Engineering Ltd.
Information Name: Beijing does not get angry cement mortar factory supply, construction program
Update Time:2015-04-25
Validity:1000000
Specifications:50
Quantity:1000.00
Price Description: RMB/
Inquire Now
Beijing does not get angry cement manufacturers manufacturers Tel: 13331056879 18311209002 Shilong mortar misfire misfire Dian Dian hardener mortar fire (explosion proof frictional sparks) does not get angry [angry mortar cement mortar, special hardener misfire basic instructions] do not get angry mortar (explosion proof frictional sparks) misfire mortar description: mainly by dolomite, quartz sand, special additives, special cement and other components. This product has not pyrophoric and high abrasion resistance, impact resistance, moisture resistance, decorative, can not afford to powder, easy construction, and encountered no impact or friction sparks. [Misfire cement mortar, special hardener misfire misfire] Features Floor Features: 1. floor by metal friction does not produce sparks. 2. Enhanced wear resistance and strength, high density concrete floor, not dust, durable, dense surface never fade. Do not get angry mortar (explosion proof frictional sparks) 3. Pre-packaged product does not require adding other materials. 4. grease resistant, easy to clean. 5. New poured concrete surface and the overall combination of short construction period. 6. Non-metallic aggregate humid environment does not rust, can increase the smoothness of the table after floor after continuous use. [Misfire cement mortar, special hardener misfire] service is not angry resistant floor construction program: do not get angry mortar (explosion-proof frictional sparks) 1, according to the building structure lofting wipe smooth baseline ink lines (such as walls + 50cm line), with the water level set in the floor area of ??the concrete pouring pouring predetermined thickness, set the horizontal elevation mark, and carefully review, control the maximum deviation irregularities within 3-5mm. 2, concreting (1) before pouring concrete foundations in the water to keep it moist. To reduce bleeding, should control water-cement ratio and slump, concrete chute with the use of artificial discharge, should not be used to pump. (2) as a poured concrete to elevation, did not reach the level of the use of local materials filled and vibrated concrete, prohibited the use of mortar repair. Use flat vibrators vibrators, and steel drum with a special rolling repeatedly, columns, corners and other parts of wood pulp wipe shoot. Calibrating after concrete grout to surface at least 3 mm thick. (3) concrete pouring is completed, the use of wear-resistant materials of construction began after the hose or vacuum equipment in addition to bleeding, repeated twice more. Wear-resistant materials of construction before the mid-stage of the construction work should wear flat shoes into the late stages of the job should wear waterproof shoes into the paper. [Misfire cement mortar, special hardener misfire misfire mortar] Scope Adaptation: (explosion-proof frictional sparks) · Applications Light plant mechanical friction workshop electronic precision instrument manufacturing workshop of oil and gas is not firing mortar library Savings high voltage transformer manufacturing plant warehouse logistics flammable cargo piled district laboratory product features enhanced wear resistance and strength of the concrete floor. Floor friction does not produce sparks. High-density, pre-packaged goods can not afford to dust mixed with other materials and does not require new poured concrete surface entirety short construction period lasting, dense surface never fade resistant grease, easy to clean non-metallic aggregate humid environment is not corroded by the continuous surface After use can increase the smoothness of inflammable and explosive materials production workshop and warehouse store. [Misfire cement mortar, special hardener misfire] Specifications steps: Do not get angry mortar (explosion-proof frictional sparks) a surface treatment a new industrial floor must be completed after a certain conservation before construction, about 28 days. 2, clear surface laitance, old paint and adhesion trash debris. 3, the complete removal of surface oil, oil king grams cleaning agent. 4, clear water, dry thoroughly and dry place. 5. Clean the surface of the required dust sweeper and a large vacuum cleaner to complete. 6, a flat surface allows clearance for 2 ~ 2.5mm, moisture content below 6%, PH value of 6 to 80. 7, floor surface roughened, dust-free sanding machine required to complete and thoroughly clean with a vacuum cleaner. 8 holes on the floor surface and obvious depression applications: (1 3 Antistatic mortar) to fill Scraping, hard work, sanding dust. Second, the screed leveling layer construction clean up, ballast for floating dust or broken pieces to be cleaned sub-grid. To make the surface layer of mortar and screed firmly bonded three to bottom with four anti-static grounding wire mesh, 30 thick layer of cement mortar antistatic V. 20 thick cement mortar anti-static surface layer VI do antistatic surface hardener. Construction of an anti-static hardener is made at the level of anti-static floor and remove mortar bleeding after starting work, carried to the surface of the processing is completed. Construction professionals should use a mechanical trowel job is completed. 2, for the anti-static hardener spreading evenly, you should calculate the amount of material (5KG / m) before construction, and put in place; antistatic surface mortar initial setting stage, even the laitance concrete surface slope broken, and then the floor hardener evenly spreading mortar antistatic surface; antistatic hardener required twice (2 / 3,1 / 3), spreading evenly, spreading in the direction of the second and first vertical, After Caesar finished, perform the installation disc mechanical trowel work, mechanical trowel job should make criss-cross each; 3, after the operation, according to the anti-static case hardened mortar, at least three times the disk is not mounted mechanical trowel Smoother operations, changes in operating speed and angle iron mechanical trowel of mortar should be considered anti-static floor hardened case adjust trowel work has been completed to the floor surface machining. Specifications 1, the surface impedance (point to point test distance 900mm-1000mm) 2, relative humidity of 40% -70%, the resistance value between the requirements of point 5.0 × 104 ~ 1.0 × 109Ω, 3, relative humidity less than 30% , require point to point resistance value between 106 ~ 108Ω. 4, and network density 6m * 6m, ground network Copperbelt width 15-20mm, thickness 0.05-0.08mm. 5, self-leveling anti-static mechanical properties and surface appearance quality execution in accordance with specifications. [Misfire cement mortar, special hardener misfire] Packing conservation: Use anti-static floor hardened mortar, to get the physical properties of the design, appropriate screening is important, when complete mechanical trowel 12 hours later, the surface should be use floor wax conservation, protection of the steady growth of wearable floor strength. Note construction temperature of not less than 5 ℃. Construction dense base thickness not less than 3 mm surface. High temperatures and dry conditions, good surface covering the construction required to prevent drying too quickly. Note: Do not get angry mortar (explosion proof frictional sparks) 1. pyrophoric materials in controlled substances 2. Storage and transportation of all raw materials in the construction process should be non-mixed in a collision easy to produce sparks friction material (such as various metal and other types of stones). 3. Before the raw material into the mixer, and all the best material to make another inspection iron absorption, especially cement, because cement is often mixed with some possible when grinding ball mill grinding debris and iron filings.
Contact Detail
Company Name: Beijing Shun Jian Industrial Engineering Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Shilong(Manager)
Telephone Number: 13331056879
Company Address: Lin and Economic Development Zone, Shunyi District, Beijing, Beijing, China
Zip/Postal Code: 101300
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450