Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

CREATE-3D integrated network management system is a dynamic environment centralized monitoring

CREATE-3D integrated network management system is a dynamic environment centralized monitoring
CREATE-3D integrated network management system is a dynamic environment centralized monitoring
CREATE-3D integrated network management system is a dynamic environment centralized monitoring

Larger photo of automa dispenser

Company:Kim Heng Innovation (Beijing) Technology Co., Ltd.
Information Name: CREATE-3D integrated network management system is a dynamic environment centralized monitoring
Update Time:2015-04-23
Validity:300
Specifications:
Quantity:1000.00
Price Description: RMB/
Inquire Now
 Product Description building purposes Power Equipment and Environment Monitoring System is through the use of advanced sensor technology, communications technology and computer technology, the engine room of the power user, batteries, high and low voltage power distribution, oil, machines and other power equipment, as well as temperature, humidity, fire, burglary and other environmental parameters in real-time monitoring, the ability to determine the fault and generates an alarm, the remote device for remote control and regulation, in order to achieve no less people on duty room. The system can improve the quality of maintenance and management of equipment, reduce maintenance costs and improve overall efficiency, so as to establish a set of users with high reliability, high efficiency, high efficiency of the maintenance system. CREATE-3D integrated network management as a professional dynamic environment centralized monitoring system, based on a variety of transmission TCP / IP, ADSL, dial-up, so as to B / S, C / S two alternative architectures, temperature and humidity, precision air-conditioning , leakage, power distribution and open space, UPS and batteries, fire, lighting control, infrared sensors, video, access control, and other equipment and environmental parameters for centralized management, through the Internet, management of each device, "five steps" (telemetry, remote, remote adjustment, remote control, remote viewing) centralized monitoring of potential danger and has happened for real-time monitoring, through sound and light, SMS, telephone, voice, desktop, email, etc. timely warning, the main interface of the overall electronic Maps with 3D animation shows, vivid and intuitive, simple operation, acquisition and integration server configuration data backup for each other, to ensure that the entire network data synchronization, configuration synchronization, automatic monitoring of room in all weather conditions, in order to achieve the goal unattended. CREATE-3D integrated network management support for custom plug-ins, open-D interface conforms to People's Republic of China Ministry of Information Industry YD-T_1363.4 communications industry standard, the ability to easily increase the monitoring equipment, the future can be easily and cost-effectively extended to other rooms monitoring (adding a node can be), with good scalability, and other monitoring systems provide transparent transmission interface. The system supports distributed authorization management, through the strict separation of different operations, regional and professional competence group administrator account is assigned to different roles, access control permissions management at different levels. Report management system, including daily reports, monthly reports, annual reports, and the time period the report, the report is divided into alarm equipment, equipment to run the report, access reports and management reporting systems into four categories, by setting the monitoring station name, device name, signal name, child system type, such as a combination of alarm type query criteria to excel or pdf format to generate, export, and print various reports, support on-demand personalized reports. Operating status of the monitored object monitor real-time monitoring of power distribution cabinet distribution cabinet table and other equipment and a variety of operating parameters, monitor the status of each distribution cabinet important switch. Intelligent power monitoring instruments should have at least the following parameters: current, voltage, active power, reactive power, apparent power, frequency, power factor, active power, reactive power. Battery tester with LCD display requirements to ensure reliable performance and ease of use. Precise monitoring of distribution cabinet to provide digital communication interface and power management unit interface protocol, capable of sophisticated power distribution cabinet operating parameters (voltage, current, frequency, active power, power factor, harmonic content and mine according to precise distribution cabinet makers module status, etc.), switching status monitoring, and has power, switch trip tips and other information and alarm functions. Switch status monitoring of the main circuit switch-off condition is monitored. When the switch is tripped or power failure, the system automatically switches to the appropriate operation of the screen, while the issue of voice and multimedia telephony and other voice alarm, notify the administrator as soon as possible, and event logging into the system. Precision air conditioning comes with air conditioning monitored by intelligent communication interfaces and communication protocols, real-time, fully air-conditioned health diagnosis, monitoring, air conditioning various components (such as compressors, fans, heaters, humidifiers, dehumidifiers, filters, etc.) run status and parameters, and the air conditioning system or modify setup parameters (temperature, humidity, the temperature limit, the lower limit humidity, etc.) through software remotely over the network, and the remote switch for air conditioning. UPS systems monitored by the communication protocol and intelligent communication interface provided by the manufacturers of UPS UPS monitoring. UPS operational status monitoring includes internal rectifier, inverter, battery, bypass, load and other parts of the UPS and various voltage, current, frequency, power and other parameters, and an intuitive graphical interface to the user. Upon detection of an alarm system or the more limited parameters, it will automatically switch to the relevant operating picture. More limited parameters will change color, and is accompanied by an alarm sound, appropriate treatment tips, and related processing tips. Intensive monitoring of temperature and humidity in the cabinet and the location away from the need to install air-conditioning temperature and humidity monitoring points. Monitoring systems in an intuitive screen real-time display of temperature and humidity data and curve, according to the set temperature and humidity alarm threshold. Requires that the sensor accuracy, temperature accuracy ± 0.5 ℃, Humidity Accuracy ± 3% RH. Fire monitored by the fire alarm control box given by the switch data acquisition module, the dry contact signal changes on the controller to monitor the fire host real-time monitoring of fire inside the room, even if unattended, can determine the fire working condition. Once the fire alarm, the system can open all the locks necessary linkage access system that allows staff to leave the scene as soon as possible. Leakage monitoring leakage sensor corrosion resistance, high strength rope induction controller and other accessories, with induction rope where there is water enclosed. Once the room leak occurred, on the induction of resistance rope under the floor will change, issued its leakage signal controller, the signal is transmitted via RS485 bus monitoring host. Monitoring system to monitor the alarm signal to the controller will immediately voice prompt, dial the phone or SMS notification in the form of duty promptly notify the relevant personnel. Require the use of leak detection systems can be positioned to require the use of leakage induction rope with color logo. After the alarm processing, color can be automatically restored. Leak detection system should be conditioned indoor humidification module main water supply valve to achieve linkage control loop control functions. Lightning arrester monitoring system to monitor damage. Once the module is detected lightning lightning, dry contact signal changes using intelligent acquisition module to the monitoring host Lightning module, real-time monitoring of the mine situation. Fresh air and exhaust system for fresh air and exhaust systems equipment running real-time monitoring, and linkage with the fire alarm system, remote monitoring related to operational status, and enables centralized and hierarchical monitoring and management. Access control subsystem monitors access control system to achieve integrated management, to achieve access to view events and other functions. Video surveillance subsystem monitors for video surveillance system to achieve integrated management, you can call to see the front of the video signal. 
Contact Detail
Company Name: Kim Heng Innovation (Beijing) Technology Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Ruben()
Telephone Number: 010-62102248
Company Address: Zhichun Road, Haidian District, Riverview Building B, ten layers, Beijing, Beijing, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450