Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Fire training tower

Fire training tower
Fire training tower
Fire training tower

Larger photo of automa dispenser

Company:Hengshui letter HSBC Tower Engineering Co., Ltd.
Information Name: Fire training tower
Update Time:2015-04-23
Validity:30
Specifications:Fire Training Tower: more for Police Fire Brigade. According to state regulations for the 3.5 m layer
Quantity:100.00
Price Description: RMB/
Inquire Now
Fire training tower fire training tower: used for Police Fire Brigade. According to state regulations for the 3.5 m layer, into a single window and double training tower training tower window, the window is 1.2 meters high and 1.8 meters wide X, internal rotation ladder. Fire training tower for outdoor poster steel frame, the size of 5 m * 3 meters. 2. The training tower design single 3.5 meters high, the top three meters high, a total of five layers. 3. The training includes floor corner tower climbing, firefighting shafts and other functions. 4. training tower facade from the second layer, each window is set two, window width 1.0 m spacing. 5. training tower window size is 1.2 m * 1.8 m, the window edge distance of not less than 0.65 m tower, window sills as 0.4 meters (5 cm anterior wall protruding tower), each layer of the windowsill from the ground 0.8 meters tall, the height of 3.5 m, 0.7 m and a staircase inside. 6. Training tower within no layer set not less than 1.5 meters wide platform, setting the top floor. 7. Training Tower Room peripherals fire ladder, fire ladder channel overhead, and 3 meters from the ground, 0.5 m wide staircase. 8. training tower consists of (1) simulation window (2) floor plate (3) skeleton (4) Lookout, command platform framework and main steel frame and other components. The front of the tower located eight analog window with partition between the upper and lower floors of adjacent analog window (use of steel). 9. tower beneath the rear has a skeleton. 10. The main frame is made of bolted assembly. 11. There stairs connections between layers. 12. There lookout tower at the top of the command platform. 13. You can install wind measurement instrument, such as cold water with a rack and sirens in the tower according to user needs. 14. In the next fire training tower design well. 15. The front of the fire training tower has two sliders 89, a window at the top platform has two rings. 16. The front portion of the front of the tower located two climbing rock, the size of 0.6 m * 0.4 m * 17 m high tower 17. galvanized or spray embalmed. Fire training tower is the country's main fire brigade fire training equipment and facilities, equipped with the necessary support facilities mainly in simulation training base, rock climbing training area, underground engineering simulation training area, underground building simulation training area, the building collapsed and rescue training area to simulate tank training area, gas tank training area, chemical and gas tank simulation training area and other fire simulation training facility. Intensive training by training tower, further enhance the skill level of training throughout the firefighting and rescue force, improve the ability to handle special disaster incidents. Building simulation training base, rock climbing training area, underground engineering simulation training area, underground building simulation training area, the building collapsed and rescue training area to simulate tank training area, gas tank training area, chemical and gas tank simulation training area and other fire simulation training facility. Reinforced by training tower training to further enhance the skill level of training throughout the firefighting and rescue force, improve the ability to handle special disaster incidents. Our company specializes in the production of fire training tower, steel fire training tower, steel and wood structure fire training tower. Fire training tower design principles: conducive duty combat readiness, business training, team management, improve the combat effectiveness of firefighting team to adapt to defend the socialist modernization and people's lives and property needs. Fire training tower design purposes: science, easy to apply fire training tower design basis: referring to national standards, design and fabrication and installation of fire training tower. Requirements and production standards in accordance with Annex (March 1983 Ministry of Public Security issued since October 1, 1981 implementation) firehouse building design standards "GMJ1--81" of Chapter VI of the building fire training tower: The first article 6.0.1 Fire training tower should be set within the station, its front shall be provided not less than 35 meters in length of the runway. Training tower should meet the following requirements: a training tower should be located at the far end, near the site of the training field; Second, the training tower should be at least four layers, more high-rise buildings of the city, the number of layers can be increased; three, training tower front window each less than two, between the window and wall width of 1.0 meters; four, training tower window size is 1.2 m × 1.8 m away from the tower side window shall not be less than 0.65 meters, 0.4 meters wide windowsill (prominent tower wall 5 cm), each sill height from the ground floor of 0.8 meters, the height of 3.5 meters, and should have a clear width of not less than 0.7 meters of internal stairs; five in each medial training tower should set not less than 1.5 meters wide platform, the top floor should be set; six, should set the outdoor fire training tower ladder. Fire ladders shall pass to the top of the tower and the ground should be set at 3 meters from the width of not less than 50 cm. Composed of multi-fire training tower, mainly by (1) simulation window, (2) floor partitions, (3) after the skeleton, (4) Lookout, command platform and the main skeleton of steel frames, etc.:) fire training tower Product Description . In the front end portion of the tower has eight analog window (customized according to needs several layers of the window), the features of floors partition plate (steel plate) between the lower adjacent analog window. 2, below the rear portion of the body is provided with a mock window column corresponding rear frame. 3, simulation and floor window frame and the main bulkhead and rear frame bolted to each other as one, four, have safety stairs connection between the layers. 5, the upper body is equipped with a lookout tower, commanding platform. 6, may be needed to install wind measurement instrument, such as cold water with a rack and sirens. 7, if necessary, next to the fire training tower can be made fire training well. 8, fire training tower is also equipped with fire special pulley, slider, simulated walls and other ancillary facilities. The training tower structure of scientific, safe, easy to use, the product embalmed galvanized or hot spraying, for 50 years without maintenance, safe and reliable. Fire training with a variety of functions, lookout, wind, alarm. At the same time easy to keep track of the fire brigade commander's action essentials. Necessary equipment is armed combat fire brigade fire training exercises of. At the same time replace the brick structure in the past history of the fire floor. Note: As the majority of the fire training tower fire brigade exercise equipment, related to the safety of the soldiers, so the choice of production at home, be sure to choose an experienced home, the soldiers militarily, the quality of the equipment used in the soldiers but also to Excellent 
Contact Detail
Company Name: Hengshui letter HSBC Tower Engineering Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Zhou Quanqin()
Telephone Number: 13103080668
Company Address: Dong Sub Avenue King County Hirokawa Zone No. 187, Hengshui City, Hebei Province, China
Zip/Postal Code: 053511
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450