Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Explosion soft starter

Explosion soft starter
Explosion soft starter
Explosion soft starter

Larger photo of automa dispenser

Company:Wenzhou Mau Vietnam Electric Co.
Information Name: Explosion soft starter
Update Time:2015-04-18
Validity:360
Specifications:
Quantity:1000.00
Price Description: RMB/
Inquire Now
Low-voltage solid-state soft starter soft start proof starter Features: QBGR Chinese computer digital display high voltage 10KV AC motor soft starters, the Department of the use of advanced single-chip microcomputer, PLC controller and color HMI touch screen and high-voltage power electronics semiconductors and modern control technology integrated into Ju new solid-state high-voltage motor starting and running protection products. In addition to an excellent start function, the product also has a complete motor integrated protection features to ensure safe electrical and mechanical equipment in a variety of situations and reliable operation. Compared with other types of high-voltage motor soft starters (such as water resistance type), due to the soft starter consume very little energy during starting, it has a significant energy savings can be used to frequent starting occasions. Meanwhile, due to the soft starter are solid state devices, and therefore also has long-term maintenance free, smaller equipment size, easy to move and good anti-vibration ability and other obvious advantages, but also has the following unique features and obvious advantages, and other high-pressure soft starter ideal replacement of traditional products. 1. Start the start of the initial voltage according to the actual situation and the need for flexible equipment to set up to 15% of the minimum supply voltage, up to 90%. In addition to the normal starting frequency 50HZ, 25HZ frequency can also be set so that the motor has a high starting torque and smaller starting current, reduced equipment operating on the grid capacity requirements, saving related equipment investment. Reduce the impact of stress on the motor and transmission machinery itself, and extend the life of the motor and the transmission of mechanical equipment. 2. Start at the initial start voltage, start time, and start-up current restrictions can be easily set up on the color LCD touch screen and achieve, and soft-stop deceleration time may be based on characteristics of the load requirements of any settings to fully meet a variety of devices and motor starters, deceleration stop working conditions. 3. A variety of start mode (step-down start and constant current start) control methods to meet the needs of various types of equipment starting performance. 4. Improve the motor protection features to ensure safe operation of equipment, protection functions;. A ultra-high input supply voltage protection alarm. b. input supply voltage is too low to protect the police. c. Input power phase alarm. d. motor running overload inverse time overcurrent protection alarm. e. high-voltage electrical current imbalance abnormal alarm. f. motor start timeout protection alarm. g. The bypass contactor fault alarm. h. Zero sequence leakage alarm equipment. I. The main circuit of three-phase thyristor power alarm and display device breakdown damage. j. Short circuit instantaneous tripping tripping alarm (settable range of 0.1-2.5 times the current transformer current). Low-voltage solid-state soft starter soft starter 5. Start proof display three-phase soft starter operating current and zero sequence leakage current and power supply voltage of the motor and the motor line at work, and shows the cumulative motor running time, and is not blackouts, easy to understand the equipment running cumulative time, easy to carry out regular maintenance and repair. 6. Display of the operating parameters are Chinese color HMI touch screen display, very intuitive and easy to set parameters. 7. according to user requirements with profibus dp communication interface, and remote monitoring on the level of computer networking communications and remote control. Description of the parameter setting function touch screen panel is displayed: Run cumulative (RUNtime): 0-9999 hours (S); but the count is automatically previous cumulative run time, and the impact of power outage, after the expiration of 9999 hours back to zero start. Starting time: seconds; 0.1 and 99.9 seconds (S) parking time: seconds; 0.1 and 99.9 seconds (S) overload current: Unit for A; generally set at about 1.2 times the rated current of the motor nameplate. Does not work in the motor during starting. When the soft starter into the run time, if the motor current reaches or exceeds this value, the controller will perform inverse time overload time, when it reaches the overload time set time, the soft starter will stop working and generate an alarm signal overload tips. Overload time: 0.1-199.9 seconds (S); when the motor current exceeds the set value overload current exceeds the set time, overload alarm is generated. This time with inverse time protection features, namely the greater the overload current actual current exceeds a set value, the protection of the shorter time. Starting voltage: Value range: 10-90%; start voltage when starting, corresponding to 10% -90% power supply voltage, the user can be set adjusted according to the actual situation of the field device. Zero sequence current: the value of the unit A, the actual detection of zero sequence current transformer signal range is 0.01-9.99A. The display is the actual value of the zero-sequence current value by the soft starter are connected to the output of the zero-sequence current transformer detected, can not be modified. Different types of users, such as the replacement of transformers shall control potentiometer P4 motherboard adjust proofreading. Starting limiting: the unit is A: The current value is the maximum current value during motor starting. In the start-up process, when the starting current of the motor reaches this value, the starter will start to increase the current limit, then the start time is set to become the biggest value of the guard time, if the load is too heavy due to causes in the starting set Start time is not yet complete, it will stop and have a "starting time" alarm, such as equipment normally available through the current value or increase the starting time limit increases to solve, we must pay attention! The value must not exceed the maximum set twice "mutual current" set value! When starting mode is selected as "buck", the parameter value is invalid. Leakage Protection: The value of units of A, the range of 0.01-9.99A. The set value is the value of the leakage current protection. When the value is set to 0.00A, this function is disabled. The current value is determined by the output of the soft starter zero-sequence current transformer connected to the detected value, when the output cable or high-voltage electrical insulation on bad ground leakage current, if the zero-sequence current transformer to the detected When the leakage current is greater than the set value, and the duration of time greater than the set value of a leak, the soft starter cabinet will stop immediately and produce (leakage blocking protection alarm) fault alarm display. When first-time users, the value can be set to the maximum, the maximum leakage current when first starting equipment observe display (usually in the starting process) and run-time general average wait after shutdown Set this parameter is greater than 20-30% of the actual leakage current can be. Leakage delay: The value of units of seconds, the range of 0.1 to 5.0 seconds. The set value is the value of the leakage current protection operation delay. When the value is set to 0.0 seconds, is the instantaneous action protection. Due to a variety of complex situations transmission cables and high-voltage electric motor when the motor is just starting the leakage current is large, but also small leakage current run, this time by setting the appropriate time delay protection, which can effectively prevent leakage protection malfunction that is, if the leakage current exceeds the user should pay attention on one! The delay function leakage into the normal operation of the motor that fails, that once the leakage current exceeds the current value of leakage protection, the soft starter will stop immediately and produce (leakage blocking protection alarm) fault alarm display. Overpressure protection: Unit for KV: This parameter is to protect the device does not work in the power supply voltage is too high the environment, and can be set at + 20% to + 25% of rated voltage, when the supply voltage exceeds the set value, The soft starter will generate (ultra-high voltage power supply alarm) fault alarm display. Undervoltage protection: Unit for KV: This parameter is to protect the device does not work due to the low power supply voltage environment, and can be set at about 35% of the rated voltage, when the supply voltage drops below the set value, the soft start will produce (supply voltage undervoltage alarm) fault alarm display. Current transformers: Unit for A: The parameters can be modified within the manufacturer of the machine transformer data set required engineers to change your password. Start Mode: Normal mode: In this mode, the motor starting from the set of "starting voltage" in a low-voltage, beginning with the start time set gradually linearly increase the output voltage until the start time ends. Low-frequency mode: especially suitable for large mechanical friction and inertia of large mechanical equipment, then start with a frequency 25HZ started when the cabinet, the motor can produce high starting torque in a small startup current, can greatly extend the life of the equipment. (This function is only used for special requirements of users overloaded start) when needed ordering. Low-voltage: This setting is low-voltage setpoint runtime. Engineer Change Password: The password value is 168. When you press the reset button, the password will be cleared. Chinese fault alarm screen display shows the contents: Motor overload alarm: the motor current has exceeded the overcurrent load current value set, and the time delay value exceeds the over load time set. The alarm will automatically reset command to undo the operation! Input power phase alarm: Three-phase input power supply controller has a similar power. Should check the input power. Abnormal motor current alarm: the motor phase or three-phase windings are three-phase current serious imbalance. Start timeout alarm: This is an alarm during starting to appear, and when you first use because "start limiting" value is too small, or "start time" value too, by increasing the "start limiting" value or "start time" value to resolve. This alarm is generated after normal use is caused by mechanical overload, should identify the reasons for re-start. Bypass switch fault alarm: After starting the device is completed, when put into operation, the bypass contactor is not closed, the number of contacts with a number I9 L1 contact is not turned down after waiting for five seconds after the alarm. Motor zero sequence leakage alarm: When the analog input port LH1, LH2 leakage signal value of the connected zero sequence current transformer leakage protection is greater than the value of a setting, the soft starter will stop and generate the alarm. When a user first installation, should leakage current range adjustment and proofreading. Ultra-high voltage power supply alarm: when the supply voltage exceeds the "overpressure protection," a set value, indicating that the power supply voltage has exceeded the protection value. Mains undervoltage alarm: when the supply voltage drops below the set value "undervoltage protection" A, indicating the supply voltage has been below the protection value. Power Devices damage alarm: When the soft starter main circuit A, B, C three-phase thyristor module breakdown when any group is damaged, the alarm will be generated. Attention! When the soft starter 380V low pressure debug panel should "Device protection" A ban is set, otherwise this will generate false alarms. After more than an alarm leads to stop running after troubleshooting by identifying the reasons (reset) button on the control panel is able to clear the alarm. Voltage soft starter number of external terminals function description and requirements: a. Each input connected to the external output ports: 10; external power vacuum contactor coil end (AC220V), the other end of the coil connection AC2. When the soft starter to start the operation, the contact of the vacuum contactor coil is energized closed. AC1; AC2: external 220V power input to work, access to the power supply, all within the soft starter controls to work and control. 20; AC4: high pressure bypass vacuum contactor coil pull soft-start control terminals. (Coil voltage AC220V) B10; B11: soft start cabinet brake signal output. When the soft starter is up and running, the two contact closure, when the soft starter is stopped, the two contacts open. Available to the user in control of the brake linkage or other devices connected to the device. LH1, LH2: external detection of zero-sequence current transformer secondary winding input. COM: Input Function Control common X0: spare. X1: spare. X2: soft start cabinet to stop working to enable end; normally closed contact, off the end of COM connection, the soft starter stops working, then disconnect the input power vacuum contactors. X3: soft start work enabled client: On the end of COM connection, input power vacuum contactor is closed, the soft starter began to start work. When the touch screen to select the direct start-up mode, the power input vacuum contactor and bypass contactor is closed immediately direct, full voltage motor starters. X4: alarm reset terminal; the port and COM terminal is turned on, the soft starter immediately stop work and enter the initial reset. Can be used to lift the alarm safety interlock protection and external devices. X5: external control side chain protection; normally open contacts, the port and COM terminal is turned on, the input of the soft starter cabinet will immediately disconnect the power vacuum breaker can be used outside of the emergency shutdown equipment and safety interlock protection. X6: door stopper chain control terminal; the port and COM terminal is turned on, the power button until the closing act, the point of disconnection will lead to disconnect the power vacuum circuit breaker. The safety limit for starting door interlock protection. X7: External remote start signal input terminal; the port and COM terminal is turned on, the soft starter will be up and running when the port is disconnected with COM, soft start immediately stop running. X10: spare. X11: soft starter started directly control terminal; the port and COM terminal is turned on, when you press the start button on the soft starter soft starter will directly contact the closed high-voltage power vacuum and high pressure bypass contactor, were conducted motor is started directly. X13: run the signal emitted by the main control board. X14: soft starter ready signal emitted by the main control board. X15: alarm signal emitted by the main control board. X16: short circuit tripping signal emitted by the main control board. II. Each output port: 24G: output indicator signal control common Y4: alarm indicator; when the soft starter alarm, the point 24G 24V DC output voltage, these two points are connected by an alarm indicator display. Users can also connect a DC24V DC relay between Y4 and 24G to expand external dry contact alarm output. Y5: brake lights; when the high voltage soft starter motor starts running, the indicator lights. Y6: Starting indicator; when the high voltage soft starter during starting, the point and 24G have 24V DC voltage output, when the startup is finished running, the light goes out. Y7: running lights; when voltage soft starter starters finished, run bypass contactor is closed, this point and 24G have 24V DC voltage output, can be carried out by an external 24V LEDs display operating conditions. More than 4 groups operating voltage indicator DC24V. Low commissioning wiring instructions; When the soft-start low-pressure testing, should be soft starter into the line above the rear end of the next three terminals are connected to the main terminal copper screws. That is, the three terminals are connected to the input of the soft starter A, B, C on, and also connected to 380V power supply, the output of the soft starter R, S, T bulb connected to a motor or resistive load, can low voltage 380V debugging. Note! (Low voltage 380V debugging, be sure to come from the low-pressure side of the high voltage transformer 220V power switch is turned off! This prevents AC220V voltage delivered by high-voltage power transformers anti-high-voltage power end !! then individually connected to a 220V power supply A21, the B21 while the power of a touch screen device protection function is set to invalid! Otherwise, damage to the device will generate false alarms.) III. Explosion-proof box installed in the parameter setting and adjustment method (special explosion Movement): There are five parameter adjustment leads to terminals in soft-start button on the front of the J2 socket, there is another button to the common line COM. Where X20, X21 to adjust parameter selection key, X22, X23 for numerical modifier keys, X27 for screen switching key. When the explosion outside the box to set parameters, you can press the X20 or X21 keys to select the appropriate parameters, the corresponding parameters are selected, it will be converted into the right side of the indicator color, then press the X22 (increase) or X23 (decrease) parameters to change the corresponding values, X27 for screen switching button, press the button, the touch screen will rotate to switch the display screen can be used to observe the screen. Four. Adjustable soft-start the main board of the parameters as follows: 1. Short trip current regulation; The control board has a short circuit on the main circuit soft start working when the impact of current instantaneous trip protection. Calibration adjustment method that functions as follows; the SRU current transformer input of a current signal termination of 1,6, 2 and 3, 4 and 5 shorted. Generally short-circuit tripping current can be adjusted to 1.6 times the current transformer primary current, after conversion, the current 1,6 end of 8A, the current is adjusted to 8A, then adjust the precision potentiometers P8, measuring measuring DL0 IC4 to the right of the hole, the voltage of about 2.5V, then adjust potentiometer P4, the socket DL1, DL2 next relay is closed, DL1 and DL2 closed at this time PLC controller will generate an alarm trip. 2. The zero-sequence current protection calibration; LH1-2 socket 2 will terminate at zero sequence current transformer secondary side, the threading hole through a current transformer signal line, the current value is zero sequence in need of protection current value adjustment precision potentiometers P10, so the touch screen display value is zero sequence current tested. 3. Initial start-adjust voltage; in general, do not adjust the project, you can start by setting the value of the voltage to change the voltage level of the motor startup, if the set starting voltage has reached more than 70% in order to meet Start voltage value, then you can adjust the main board potentiometer P5, while UY test hole potentiometer measuring the upper left to the voltage of about 2-5V, the higher the voltage, the motor voltage when it started higher. All aspects QBGR voltage soft starter wiring diagram see attached: conditions of product use: Power supply: three-phase AC 6KV. Applicable motor: three-phase high voltage induction motors. Start times: no more than 10 times per hour, every time you start interval longer than six minutes. Cooling: natural air cooling or forced air cooling (depending on the size and capacity of the working conditions). Installation: Mounting in the cabinet. Conditions of Use: less than 2000 meters above sea level. Over 2000 meters, should be appropriate to reduce the number of rated power and frequent start. Ambient temperature -25 to + 45C, relative humidity less than 95% (20C), undoubtedly exposed. Non-corrosive gases, non-conductive dust. Low-voltage solid-state soft starter soft start proof starter 
Contact Detail
Company Name: Wenzhou Mau Vietnam Electric Co.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Peng Zongqi()
Telephone Number: 0577-26663996
Company Address: After Liu Yueqing municipal Jiecun, Wenzhou City, Zhejiang, China
Zip/Postal Code: 325604
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450