Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

2V / 200A fixed energy VRLA batteries

2V / 200A fixed energy VRLA batteries
2V / 200A fixed energy VRLA batteries
2V / 200A fixed energy VRLA batteries

Larger photo of automa dispenser

Company:Kaifeng Flying Technology Co., Ltd.
Information Name: 2V / 200A fixed energy VRLA batteries
Update Time:2015-04-07
Validity:300
Specifications:
Quantity:100.00
Price Description: RMB/
Inquire Now
2V / 200A fixed energy VRLA battery is Flying technology companies to fully digest and absorb foreign advanced technology. Products using the new import microporous separator and electrolyte, the battery positive and negative plates to optimize formulations, making it than conventional VRLA batteries have the following advantages: smaller, lighter weight, excellent resistance to deep discharge performance, charge retention capacity high, longer cycle life characteristics. Our products are widely used in telecommunications, electricity, energy storage, marine, military aviation industry. I. Introduction to the electrolyte required sealing principle component injection absorbent excellent fine glass fiber separator, no free electrolyte, anode plate by moist to increase gas recombination ability, scientific structure and formulation of the positive plate oxygen gas generated during charging of the negative electrode plate quickly react returned to the active substance in water, due to the minimal loss of the configuration can be sealed. The new formula of high-alloy corrosion rate discharge very excellent self-discharge rate is very low fine glass fiber membrane pipette no harmful gas overflow superior low-temperature properties of high strength ABS resin shell and equipment at the installation does not pollute the environment with fully sealed without adding water does not leak automatic opening and closing valve built-free battery room two, GFMG energy type VRLA battery float charging a 12V series battery float voltage per cell 13.50-13.80V ± 0.02 (25 ℃), charge voltage per cell 14.10 -14.40V, this float voltage with the ambient temperature by 3mv / ℃ lower. 2V series battery float voltage per cell 2.23-2.27V ± 0.02 (25 ℃), charge voltage per cell 2.35-2.40V, this float voltage with the ambient temperature by 3mv / ℃ lower. Recycle 12V series battery charging voltage to each of the largest ever single cell 14.4-14.70V, the recommended initial charging current current rated capacity of 0.1 to 0.2 (A). When the current drops below 0.006CA, three hours unchanged and stable, can be put into normal use. 2V series battery charging voltage to a maximum of once per cell 2.35V, the recommended initial charging current current rated capacity of 0.1 to 0.2 (A). When the current drops below 0.006CA, three hours unchanged and stable, can be put into normal use. Three, 2V / 200A fixed energy VRLA battery installation, use precautions batteries should be placed in ventilated, dry place away from heat and difficult to produce sparks, safety distance of 0.5 m or more. The availability of longer life 25 ℃ temperature environment, the long run if the temperature rises 10 ℃, life expectancy was reduced by approximately half. Within a temperature range of 25 ℃ -0 ℃ if each drop 1 ℃, the discharge capacity decreased by about 1%. Installation should pay attention to the polarity of the battery, connect the positive cathode battery charging equipment or load, the negative battery charging equipment or the negative pole of the load, is strictly prohibited reversed. Since the voltage of the battery pack is relatively high, in the installation, use and maintenance process should wear gloves edge to prevent electric shock. Different models, different types and different battery recency not string, and used together. Battery pack before connecting with a fine wire brush to clean the terminals on the oxide film, making it appear metallic luster, the battery pack must be securely connected at each connection, bolt and nut torque of about 11 Nm. When handling batteries should be at the normal position, should not be subject to severe vibration and shock. Note Do not crash when installing terminals, must not allow the terminals shorted, non-hanging terminals handling, to avoid affecting the sealing performance. GFMG energy type VRLA battery is fully charged the factory, there are varying degrees of damage from the factory to the installed capacity between use, before use should be a reply to the charge. To have a longer battery life, good performance, use an automatic voltage regulator limiting charging equipment. When the load is in the normal range, charging equipment should reach regulation accuracy of ± 1%, the charging device should be able to meet the charging requirements of this specification requirements. Please do not stop the float float during non-work use. Non-discharge, the process of using every single cell voltage drops below 2.0V generally not. Must adopt advanced constant voltage charging, the charging voltage limiting device. Four, 2V / 200A fixed energy VRLA battery maintenance and precautions: After a period of time the battery should be carried out to determine the battery discharge test online capacity. Once a year to check for the actual load discharge test, the release of 30% -60% of the rated capacity. Capacity test done once every three years, to be once a year for six years after use. 1, the battery is put into operation, the float voltage measured weekly, and make the following records: (1) Each single battery float voltage (2) The total battery voltage (3) the ambient temperature 2, a proven track record in time elimination of battery charging, maintenance or environmental aspects of battery causing adverse effects, provide the basis for the exclusion of battery failure. 3, regular (1-2 times a year) to check the connection bar is loose, if there is loose and should be tightened. 4, can not use the battery in a sealed container. 5. scrapped after use, do not throw batteries, please contact the manufacturer for recycling regeneration. Tips more communication power supply battery products visit www.kfsfkj.com.cn www.sfdianyuan.com.cn 
Contact Detail
Company Name: Kaifeng Flying Technology Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Korean general()
Telephone Number: 0371-23951653
Company Address: Jinming Avenue South, Kaifeng City, Henan Province, China