Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Industrial submersible aerator QXB2.2

Industrial submersible aerator QXB2.2
Industrial submersible aerator QXB2.2
Industrial submersible aerator QXB2.2

Larger photo of automa dispenser

Company:Processing Equipment Co., Ltd. Nanjing Lan river
Information Name: Industrial submersible aerator QXB2.2
Update Time:2015-04-07
Validity:120
Specifications:QXB2..2
Quantity:100.00
Price Description: RMB/
Inquire Now
Submersible aerator selection of Nanjing blue river Treatment Equipment Co. specializes in manufacturing QXB centrifugal submersible aerators, various aerators Guinness, please contact use:! QXB centrifugal submersible aerators for wastewater treatment plant aeration tanks, aerated grit chamber, to a mixture of sewage sludge oxygenation and mixing, and biological treatment of sewage or aquaculture ponds oxygen. Principle: QXB centrifugal submersible aerators for direct coupling structure. Rotating impeller produces a centrifugal force in the water, by the centrifugal force in a zone of negative pressure is formed around the impeller, the air is sucked through the intake pipe and is sucked into the air and water are mixed in the mixing tray, which then automatically good uniform mixture from the discharge export ejected four weeks. This process includes the following aspects: Mixed intraday air is mixed with water to produce a gas-liquid mixing effect, outlet gas-liquid mixture form a cycle and convection; a large number of molecular oxygen in the air to get a high-speed movement of oxygen absorption efficiency . Features: a high oxygen dissolution rate, the percentage of tiny bubbles, high efficiency and oxygenation oxygenation wide area; two pools no dead zone, the level of aeration bubbles entrained flow completely scour every corner of the bottom of the ; 3 structure is simple, compact, long unit life, can withstand heavy load bearing, shaft seal with oil bath air impeller and suction chamber to prevent contact with water and seal work, these are guaranteed aerators in 24 hours of continuous work Long-term trouble-free operation; 4 save project investment, without providing gas source, eliminating the need for fans, easy installation, low noise; Schematic: QXB centrifugal aerator three main technical parameters, QXB centrifugal aerator Caution 1, Never allow cable aerators with lifting or suspension aerators. In carrying or hanging aerators are available with fishing hook on a chain handle or lid on the rings. 2, the fruit is still in use aerators or immersed in water, when the temperature below 0 ° C, you can continue to use. 3, aerators use grease or oil, since the seal wear, grease or oil will leak. Time. Please hurry the aerator to the maintenance department of the company or delegate maintenance, replacement sealed to prevent motor burnout. 4, the end cut off the power, not moving aerator, who shall enter the water. 5, after the installation of submersible aerator, not long-term immersion in water and do not recommend running at least every four hours and a half to check its functionality and adaptability, or bring in a dry place for use. 6, sewage submersible aerator can not be placed outside the entrance. When the chassis on mud or quicksand, submersible aerator subsidence due to vibration generated, in this case, we recommend that the aerators mount up or placed on a larger negatives. 7, diving aerator is necessary to ensure safety. QXB centrifugal aerator maintenance instructions for each factory, are carefully carried out the final inspection to ensure product reliability using submersible aerator. In order to ensure the life of the boldness of the machine, we recommend regular inspection and maintenance. 1, cleaning in order to prevent diving aeration plot within different periods of impurities, can dive aerator pump clean water to clean the diving aerator. Submersible aerators unused for long periods, should be placed in a dry place, and pay attention to antifreeze. 2, grease and oil change oil chamber submersible aerators at the factory, has been injected into the right amount of oil. The oil should be replaced annually. Oil change according to the following method: Place the submersible aerator good, so that the oil chamber plug down, loosen the plug, release oil, then washed with oil washing oil chamber, and then inject the right amount of lubricant, for a New Ο-ring, tighten the plug. If the oil is found in the water, according to the provisions of flushing oil chamber and re-filled with oil, tighten the plug tight with O-rings. Must be checked once again, if the oil has become an emulsion, respond mechanical seals to be checked after three weeks. Replace if necessary (please contact with our maintenance department). Note: The oil for transformer oil. 3, in case of operational failure faulty operation, if not determine the cause, according to the troubleshooting methods given later still unresolved, not using makeshift methods, and do not mess repair indiscriminate demolition without permission. Six, QXB centrifugal aerator troubleshooting Symptom Cause removal method overload a power plant into the pool does not meet the requirements of two submersible aerator blades and guide vanes wound debris leaves replaced senescent three diving submersible aerator friction 4 aerator speed exceeds a specified value to improve water conditions two clear debris, washed three checks blade wear, re-adjust the installation of four prime mover adjustment to conform to the rated speed to reduce the amount of aeration or aeration a water exposure dive into the depth of the air dryer is too deep cylindrical impeller blades wear two or three submersible aerator blade part Jihuai wrong turn 4 impeller submersible aerator loose five impurities clog an increase submersible aerator 2 3 correct replacement impeller rotation direction of the four fastening screws 5 Clear debris removal device base running water noise or vibration a submersible aerators are not strong enough or nuts loose impeller and guide leaves replaced senescent friction 2 3 impeller blade screw loose or partially damaged four water status is not submersible aerators stable five impurities clog a reinforced base, tighten the screws 2 Check impeller and guide vanes gap 3 Tighten the screws to adjust or replace the impeller inlet state 4 5 clear the debris, clean water submersible aerator can not start or blown fuse a winding, two submersible connector or cable break clogged aerator 3 4 short circuit leakage or leakage inspection using an ohm meter diving 2 off the power, remove debris 3 Check the insulation, lower than the specified value, inspection and maintenance must be carried out after drying 4 After starting aerators breakers, overload disconnect a high voltage and low voltage 2 3 electrical wiring or connectors not confuse four control cabinet is not used for an electrical fault or because the line was too long and cause blood pressure, should be bold power line 2 installed transformer, the voltage to a predetermined value adjustment wiring and connectors 3 4 Check and replace electrical components 
Contact Detail
Company Name: Processing Equipment Co., Ltd. Nanjing Lan river
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Lu Jiang(Manager)
Telephone Number: 025-57653626
Company Address: Xiongzhou Road Town, Luhe District No. 8 Xiongzhou, Nanjing, Jiangsu Province, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450