Home
Products
Temperature and humidity box factory in Dongguan Huakai temperature and humidity chamber
Temperature and humidity box factory in Dongguan Huakai temperature and humidity chamber
Temperature and humidity box factory in Dongguan Huakai temperature and humidity chamber
Name: Walk-in constant temperature and humidity room Model: HKW-235 Brand: Huakai Huakai testing equipment Technology Co., Ltd., Dongguan, Guangdong Province, on the 4th address Ming Leung Ka Wah Road Shijie Town, Dongguan City, Village Product Information 1. temperature and humidity chamber for the detection electronics, electrical appliances, food, automotive, rubber, plastic rubber, metal and other products, can simulate different environmental conditions of high temperature and high humidity, low temperature, humidity, etc., but with the program is easy to operate and learn to control and high accuracy of sentinel control system to provide the best test performance. Dongguan Huakai small series, the following briefly the temperature and humidity chamber operating points; first when making environmental testing, the required performance of the test sample, test conditions, test procedures and test techniques to be familiar to the test equipment used technical performance to be familiar with the equipment to be constructed understand, especially the operation and performance of the controller should be familiar with. Also read the test equipment operation manuals, to avoid operational errors caused by the normal operation of the test equipment is not causing damage to the test sample, the test data is incorrect. Secondly, a reasonable choice of test equipment. In order to ensure the normal test, the test sample should be depending on the situation, select the appropriate test equipment, we must maintain a reasonable proportion between the effective volume of the climatic chamber and the chamber of the test sample. Heating test for the test sample, the volume should be less than one tenth of the effective volume of the chamber. For non-heat test sample volume should not exceed one fifth of the effective volume of the chamber. If you have any questions need advice, please contact our professional staff, we look forward to your call. Because the focus of the testing equipment produced more than ten years, so professional in this industry. 2. The temperature and humidity chamber for the detection electronics, electrical appliances, food, automotive, rubber, plastic rubber, metal and other products, can simulate different environmental conditions of high temperature and high humidity, low temperature, humidity, etc., but with easy operation and high learning programming control and pointing accuracy of the control system to provide the best test performance. Dongguan Huakai small series, the following briefly the temperature and humidity chamber operating points; first when making environmental testing, the required performance of the test sample, test conditions, test procedures and test techniques to be familiar to the test equipment used technical performance to be familiar with the equipment to be constructed understand, especially the operation and performance of the controller should be familiar with. Also read the test equipment operation manuals, to avoid operational errors caused by the normal operation of the test equipment is not causing damage to the test sample, the test data is incorrect. Secondly, a reasonable choice of test equipment. In order to ensure the normal test, the test sample should be depending on the situation, select the appropriate test equipment, we must maintain a reasonable proportion between the effective volume of the climatic chamber and the chamber of the test sample. Heating test for the test sample, the volume should be less than one tenth of the effective volume of the chamber. For non-heat test sample volume should not exceed one fifth of the effective volume of the chamber. If you have any questions need advice, please contact our professional staff, we look forward to your call. Because the focus of the testing equipment produced more than ten years, so professional in this industry. Model HKW 4 6 8 13 17 21 system balance debugging system thermostat temperature range up to the test temperature 80-100 ℃, the lowest test temperature of -65 ℃ humidity range of 20% to 95% rise time within 20 ℃ -80 ℃ 60 分钟 cooling time 20 ℃ - -55, -40, -10 120,90,60 minute box size width 210 300,390,300,390,480 height maximum of 210 210,210,210,210,210 deep 205 205,430,430,430,430 content volume 9 12.9 16.8 16.8 35.2 133 Carton Dimensions Width 325 415,505,505,505,595 high 235 235,235,235,235,235 deep within 225 225,225,225,450,450 Carton box material stainless steel plate material of high density polyurethane foam insulation material cold refrigeration system semi-hermetic compressors no safety device fuse fuse switch, compressor overpressure, overheating, over-current protection, fan overload protection, dry protection water protection work environment 5-35 ℃ Power AC380,50HZ main technical indicators (can be customized) 1, indoor work room clearance dimensions: 5.5m (W) × 2.8m (H) × 5.5m (D) 2, Dimensions approximately: 3 to the actual subject, window size: demisting perspective window size: 2: 300 × width High 450mm; 4, temperature range: -70 ℃, -40 ℃, -20 ℃, 0 ℃, 150 ℃ temperature fluctuation: ± 0.5 ℃ temperature uniformity: ± 2 ℃ 5, Humidity: 20% ~ 98% RH Humidity fluctuation: ± 2% RH humidity uniformity: ± 2.5% RH Humidity deviation: ≤ ± 3% RH (> 75% RH) ≤ ± 5% RH (≤75% RH) 6, a heating rate of approximately: 1-3 ℃ / min cooling rate of about: 0.7 ~ 1 ℃ / min 7, noise: ≤65dB 8, wind speed, indoor air convection 9 no room to meet the staff, including 10 long, water and drainage channels: the need for a circulating water the system can ensure the water temperature at a constant temperature deviation range of ± 1 ℃, the water temperature can be adjusted in the range of 10-30 ℃, you need to configure a faucet and a drain (drain tank manhole incidental supply requires the use of the abundance of water pipes, drainage pipes using PVC-C pipe) 11, Power: 380V ± 10%, the switching device 100A above technical data are run at room temperature 20 ± 5 ℃, relative humidity ≤85% RH, non-linear lower chamber load conditions, the cooling water temperature of 5 -30 ℃, pressure cleaning 0.1-0.3Mpa between fresh water, constant temperature and humidity data measured two hours later.
Contact Detail
Company Name: | Dongguan Huakai testing equipment Technology Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Ms Yip(Salesman) |
Telephone Number: | 0769-38921656 |
Company Address: | Guangdong Dongguan Shijie Leung Ka Ming-hua village on the 3rd, Dongguan City, Guangdong, China |
Zip/Postal Code: |
Find More Related Products
- Reliability OGP non-contact..
- Guangzhou Mai Duoqi pie Aff..
- Which hospital circumcision..
- Wing Chun Wu Jiaotai mounta..
- Wing Chun Hall Taishan Road..
- BCJ-52 proof emergency doub..
- Well-known manufacturers of..
- Where recycled elm polyethe..
- Hebei wheat joined more pie..
- Beijing wheat pie join more..
- Jimmy joined Nanyang more p..
- Jimmy joined Nanyang more p..
- Smart mouse NF-306 tester h..
- Frozen fish cutters | elect..
- Single deck sofa custom lar..
- Indonesian food import clea..
- Yangzhou to Qingdao Chengya..
- Xi'an to Pingxiang freight ..
- What is good medicine mild ..
- Lianyungang import customs ..