Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Shenzhen clean room renovation contract, Elegant Man (certified), clean room decoration

Shenzhen clean room renovation contract, Elegant Man (certified), clean room decoration
Shenzhen clean room renovation contract, Elegant Man (certified), clean room decoration
Shenzhen clean room renovation contract, Elegant Man (certified), clean room decoration

Larger photo of automa dispenser

Company:Shenzhen Man elegantly decorated Engineering Company Li..
Information Name: Shenzhen clean room renovation contract, Elegant Man (certified), clean room decoration
Update Time:2014-12-27
Validity:0
Specifications:Limited
Quantity:
Price Description: RMB/
Inquire Now
 Clean operating room with indoor microbial control objectives, operational parameters and indicators of clean room grade decoration, air cleanliness is necessary security conditions. Clean operating room by the cleanliness can be divided into the following levels: 1. Special clean operating room: the cleanliness of the surgical area clean room for one hundred Shenzhen renovation contract, the surrounding area is one thousand. Suitable for burns, joint conversion, organ transplantation, neurosurgery, ophthalmology, orthopedic and cardiac surgery and other sterile surgical; 2. clean operating room: the surgical area cleanliness is one thousand, ten thousand surrounding area is suitable for Thoracic Surgery, plastic surgery, urology, hepatobiliary and pancreatic surgery, orthopedic surgery and egg retrieval, such as sterile surgical; 3. General clean operating room: the surgical area cleanliness of ten thousand, one hundred thousand for the surrounding area, suitable for general surgery, dermatology and abdominal surgery such as surgery; 4. quasi clean operating room: air cleanliness of one hundred thousand for obstetrics, surgery and other anorectal surgery. Cleansing operation of the other buildings in addition to the cleanliness level and bacterial concentration should comply with the appropriate level, the relevant technical parameters shall comply with the relevant regulations, see the main technical parameters of the cleansing operation at all levels of space. Layout cleansing operation in accordance with the general requirements should be divided into two parts, with the non-clean areas clean area. Operating rooms and function space directly to the operating room services should be located in a clean area. Cleanliness and objects through different areas surgery department, should be set airlock, buffer chamber or transfer window. Generally located in the central part of the operating room. Internal plane and channel should be consistent with the principles of functional processes in the form of the Czech Republic and clean sewage moments distinct. Several clean nursing care ward of a hospital ward cleanliness into isolation wards and intensive care units. Isolation wards divided according to the biological risk P1P2P3P4 four grades. P1 wards basically the same as the general wards, foreign people in and out is not specifically prohibited; P2 P1 ward ward stringent than the general prohibition of outsiders access; P3 wards set up buffer chamber doors or severely isolated from the outside, the negative pressure inside the room; P4 use of isolation wards area with the outside world cut off, the indoor constant negative pressure 30Pa, health care workers to wear protective clothing to prevent infection. There ICU ICU (intensive care rooms), CCU (cardiovascular patient care rooms), NICU (preterm child care room) and leukemia room and so on. 242 leukemia room temperature, wind speed 0.15 ~ 0.3 / m / s, relative humidity of 60% or less, the cleanliness of one hundred, and should make the most clean air into the patient's head first arrived, so the nose and mouth breathing zone air side, the use of horizontal flow better. Burn ward after tests showed bacteria concentration, vertical laminar flow for open treatment has obvious advantages, layer injection speed 0.2m / s Shenzhen Longhua clean room decoration company, Shenzhen temperature of 28 to 34 clean room decoration, cleanliness in thousands level. Respiratory ward in the country is rare, this ward on the indoor temperature and humidity requirements more stringent temperature control in 23 to 30 this slaughter, relative humidity of 40 to 60 percent, according to the patient's own wards regulation, cleanliness controlled at 10 ~ between 10,000 and noise of less than 45dB (A), who entered the ward should be subject to change clothes, and other personal air shower purification, maintain a positive pressure within the ward. Shenzhen clean room renovation contract, Elegant Man (certified), clean room decorated Ltd. provided by Shenzhen City Man elegant decorative design. Shenzhen Man elegantly decorated Engineering Company Limited (www.szmdyzx.com) quality services and products, and are subject to approval and confidence in the new and old customers and the industry. Our company is a certified member of the whole network Commercial Union, Commercial Union customer service icon on the page, you can talk directly with our customer service staff, to our future cooperation happy! 
Contact Detail
Company Name: Shenzhen Man elegantly decorated Engineering Company Li..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Yang()
Telephone Number: 0755-21521126
Company Address: Shenzhen Luohu District, ho Building Room 1402, Building A, Shenzhen City, Guangdong, China
Zip/Postal Code: 518000
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450