Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Affiliate Jincheng instrument supply H-2000 type PM2.5 detector portable formaldehyde detector

Affiliate Jincheng instrument supply H-2000 type PM2.5 detector portable formaldehyde detector
Affiliate Jincheng instrument supply H-2000 type PM2.5 detector portable formaldehyde detector
Affiliate Jincheng instrument supply H-2000 type PM2.5 detector portable formaldehyde detector

Larger photo of automa dispenser

Company:Xuzhou Jincheng Environmental Protection Equipment Co.,..
Information Name: Affiliate Jincheng instrument supply H-2000 type PM2.5 detector portable formaldehyde detector
Update Time:2014-12-08
Validity:365
Specifications:93 (W) × 180 (H) × 46 (D) mm
Quantity:999.00
Price Description: RMB/
Inquire Now
Jincheng instrument joined H-2000-type air purifiers efficiency portable formaldehyde detector detector cities PM2.5 particles are burst table every day! ! That our family is not exceeded super? In the end how much particulate matter? Air purifiers really can remove particulate matter PM2.5 it? Now you only need a PM2.5 particle detector. Real-time control at home parent can each place pm2.5 particles in the end how much! ! Instrument Description: CLH-2000-type air purifiers efficiency detector is designed to measure the volume of air cleaner dust particles out of the air within the air units and calculate the efficiency of the instrument according to the number of dust particles out of the air intake which is advanced haltech companies. High sensitivity based on micro-sensor technology to develop a set of independent aerodynamics, digital signal processing, optical and electrical integration of high-tech products. The basic principle is the laser scattering by dust particles on the pulse signal output by the optical sensor digital signal processing, measurement parameters setting, the results showed that key, the time, date, etc. by the built-in microcomputer (MCU) and to achieve control. CLH-2000-type air purifiers efficiency detector can simultaneously both size range (0.3,2.5) were detected and analyzed, the instrument is set to default before the measurement, the instrument is, then the user will get a unit volume measured at the inlet The number of particles in the dust automatically after 20 seconds after the display settings, the user at this time took the instrument to measure the outlet for 20 seconds after the measurement is automatically calculated based on the number of dust particles out of the air outlet which currently measured purifying machine purification efficiency. The test instrument has high precision, stable performance, versatility and strong, easy to operate, meet and exceed all performance of similar products. Its purification efficiency air purifier targeted testing, effectively reflects its purification effect. Users only need to use this instrument were air purifier inlet and outlet were measured, it can accurately reflect the number of real-time particulate matter before its purification, and calculate the percentage of its purification efficiency, therefore, this instrument is very useful for air purification purifier effectiveness analysis testing. Air purifiers detector efficiency is mainly imported from abroad with high sensitivity, high resolution, high stability and high precision sensor dust particle analysis is an important part of the pump through the pump to collect data, and then through the sensor detection and analysis and then analyze the data in real time to reflect on the LCD monitor. Main Specifications: Test particle diameter: 0.3μm, 2.5μm light: laser diode flow: 500ml sampling time: 20 seconds test mode: Concentration (per liter) Power: Li-ion, lithium-ion battery (7.4V / 1000mAh) or AC / DC adapter (AC Input: 100 ~ 240V, 50 / 60Hz, DC Output: 9V, 1.5A) Battery working time: continuous testing time is about three hours Dimensions: 93 (W) × 180 (H) × 46 (D) mm Weight: about 600g (including battery) Environmental conditions: Working environment: 5 ~ 45 ℃, <90% RH Storage environment: -20 ~ 50 ℃, <90% RH Standard Accessories: AC / DC adapter, portable protective case Appendix: About dust particle counter air particle counter particle size distribution and special equipment to test the air particles of dust particles from the microscope evolved, through the microscope, settling tube, settlement gauge, centrifugal sedimentation analyzer, particle counter, laser particle counter air process PCS nm laser particle counter air, where the air due to laser particle counter test speed, wide dynamic distribution, without human influence, such as various advantages, many industries in recent years and become a mainstream product. Different standards of classification 1, according to the test principle: light scattering method test (white, laser), microscopy testing, weighing method, DMA test method (particle size analyzer), inertial test method, diffusion test, the combination of nuclear law Test (CNC) and the like. 2, according to traffic: small flow 0.1cfm (2.83L / min) high flow 1cfm (28.3L / min) 3, according to the shape, volume size: handheld, desktop 4, according to the test channel: Single (only for a certain kind of particle diameter); dual-channel (two kinds of testing a particle diameter); Multi-channel (test multiple particle diameter) 5. Other: particle counter applications neck collar. Formaldehyde pollution on human health hazards of formaldehyde has been identified by WHO as carcinogenic and teratogenic substances, is a recognized source of allergy is caused by one of the strong potential mutagens. Studies have shown that: Formaldehyde has a strong carcinogenic and tumor promotion. Well documented, the impact on human health formaldehyde mainly in abnormal smell, irritation, allergy, pulmonary function abnormalities, liver dysfunction and immune dysfunction and so on. Its concentration reaches 0.06 -0.07 mg per cubic meter of air / hour m3, minor child asthma occurs. When the indoor air formaldehyde content of 0.1 mg / m3 when there is smell and discomfort; reached 0.5 mg / m3, can irritate the eyes, causing tears; reach 0.6 mg / m3, can cause throat discomfort or pain. At higher concentrations, can cause nausea, vomiting, cough, chest tightness, shortness of breath or pulmonary edema; reach 30 mg / when m3, would immediately cause death. Long-term exposure to low doses of formaldehyde can cause chronic respiratory disease, caused by nasopharyngeal cancer, colon cancer, brain tumor, menstrual disorders, mutations nucleus, within the DNA single-strand DNA cross-linking and cross-linking of proteins and inhibit the repair of DNA damage, pregnancy syndrome, cause neonatal chromosomal abnormalities, leukemia, causing adolescent memory and mental decline. In all contact persons, children and pregnant women are particularly sensitive to formaldehyde more harmful. World Health Organization (WHO) working group had formaldehyde provides its smell, eye irritation and respiratory tract irritation potential carcinogenicity threshold, and noted that when the concentration of formaldehyde in the indoor environment exceeded 10%, it should be taken seriously enough. Formaldehyde serious pollution hazard sites newly renovated rooms, offices, conference rooms, hotels, KTV rooms and home. With malls, shopping malls and other building materials. Formaldehyde and other indoor air pollution in people's new home and office interior spaces should be carried out and buy homes. Club, due to renovations and home. To use a lot of artificial board manufacturing (such as plywood, Daixinban, MDF, particleboard, Laminate flooring and laminate flooring, etc.), production of wood-based panels and require extensive use of highly toxic raw materials for the manufacture of formaldehyde adhesives, due to the release of formaldehyde adhesives for a long period, usually 15 years, resulting in formaldehyde in indoor air has become a major pollutants. In mid-August 2001, the Consumers Association released a startling findings, respectively, after the sampling of indoor air show in Beijing and Hangzhou, the formaldehyde concentration in excess of 73.3%, respectively, and 79.1%, exceeding the highest reach forty times. Last year, the inspection department of the Beijing area have nine home. With the city conducted air quality testing, sampling and found that formaldehyde is higher than the average of the test results public places 3.3 times the standard. Public health standards higher than the maximum 15.8 times, exceeding 98% of the sample, respectively. July 2001 Hefei health department informed the office and indoor air monitoring results for the city's 15 monitoring points: formaldehyde exceeded all, up to 85 times. Indoor air pollution alarming. Hefei ICBC branch co-workers installed yellow for 15 months, but the two offices has pervaded "smell" and often found a large number of dead worms, workers have also repeatedly reflected tears, sore throat, chest tightness, headache other symptoms. Monitoring results showed that the office exceeded 45 times a formaldehyde, an overweight 29-fold. According to Nanjing Indoor Environment Monitoring Center staff surnamed Qian introduction, the center was established in response to public request two months, a total of 30 sets of Nanjing residents near the newly renovated rooms were monitored, almost no one can fully meet the "China Health Standard indoor environmental standards ", the main problem is formaldehyde, formaldehyde as high as 40 times. Sichuan Provincial Institute of Industrial Hygiene and Occupational Disease Prevention informed that the recently renovated for over 1500 of the room and the office, the office for testing found that indoor air pollution greatly exceed national health standards. More than 95% of the room within formaldehyde exceed health standards, up more than 60 times the standard; some organs Office Interior excessive levels of formaldehyde in the air several times to several times. Xuzhou Jincheng Environmental Protection Equipment Co., Ltd. has been certified by the National Beijing metering. Instrument and meter measurement certification through the National CMC, each instrument has a separate certification report, a copy of each client we will gift! ! ! I produced Jincheng JC detector committed to national standards: focus Gas field; safeguard users' lives safe! We work together to make your life safer Xuzhou Jincheng environmental policy of "innovation, integrity, cooperation and win-win" credo, to create a well-known brand of environmental protection! Within three months after the receipt of the instrument, there is no quality problems, free replacement internal electromagnetic Pump 5 years free replacement instrument three years of free maintenance, life-long free maintenance offer OEM production Xuzhou Jincheng environmental care nationwide health of each family member! ! Contact: Miss Zhao Tel: eighteen O OO five thousand two hundred and eleven one O QQ: 78489282 joining Jincheng instrument H-2000-type air purifiers efficiency portable formaldehyde detector detector 
Contact Detail
Company Name: Xuzhou Jincheng Environmental Protection Equipment Co.,..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Zhao Xue(Sales)
Telephone Number: 0516-85559606
Company Address: Huaihai Road 270, Xuzhou City, Jiangsu Province, China
Zip/Postal Code: 221000
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450