Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

FMZX-60 Pipeline UV sterilizer 1

FMZX-60 Pipeline UV sterilizer 1
FMZX-60 Pipeline UV sterilizer 1
FMZX-60 Pipeline UV sterilizer 1

Larger photo of automa dispenser

Company:Shijiazhuang Guanyu Environmental Protection Equipment ..
Information Name: FMZX-60 Pipeline UV sterilizer 1
Update Time:2014-12-08
Validity:300
Specifications:Standard
Quantity:8506.00
Price Description: RMB/
Inquire Now
13833174989 www.gyxdq.com www.gyzwx.com UV disinfection is now used by many units, mainly sterilization fast, no side effects, does not change the physical properties of water, and chemical properties. Ultraviolet disinfection sterilization equipment will become the future necessities. UV disinfection is mainly used in raw water, secondary water treatment, sewage treatment, clean water and so on. UV disinfection advanced technology, both inside and outside polished arc head, more thorough sterilization. UV disinfection tube and flange are made of material 304 or 316 stainless steel. UV disinfection Shijiazhuang UV lamp used all imports of US original lamp Laisuo Si, more than 12,000 hours life guarantee. UV disinfection models from two tons of water per hour to process 500 tons of water per hour. Ultraviolet disinfection for the inlet and outlet openings, opening, side opening ceremony, can be processed according to customer requirements. Ultraviolet disinfection can be used as a control cabinet mounted, under-mounted, split. Can be processed in accordance with customer requirements. UV applications in water treatment has several decades of history. However, due to its technical complexity, high cost, its application is limited. But now foreign UV technology has been widely used, banned the traditional chlorination, and the price is lower than traditional chlorination. The seventies, due to increased awareness and improve public health, water pollution, and forcing people to adopt new approaches in the treatment process on the basis of traditional ensure compliance with water quality standards for drinking water safer. After nearly two decades of research and practice, with a composite of ultraviolet-based application technology, its good treatment effect become the preferred depth of the water purification technology. (1) UV treatment for municipal wastewater effluent disinfection meet the current requirements of the domestic landscape and green water. (2) The technology has no secondary pollution characteristics, application prospects. (3) low energy consumption, low operating cost; high degree of automation; maintenance is simple. In addition, after the UV disinfection sewage can be reused in many areas to achieve water resource. It is used for irrigation of farmland, woodland and lawns, chemical disinfectants can avoid damage to plants; groundwater recharge can be used to prevent microbial and chemical disinfectants produce adaptive re-breeding caused by blockage formation. With the in-depth study of the mechanism of UV disinfection, UV technology continues to develop and disinfection unit designed to continuously improve, ultraviolet disinfection is expected to become one of the main methods instead of the traditional three-drug disinfection, UV disinfection effect 1. Use by UV water disinfection system treated water, fresh water or other water body, the various types of viruses, bacteria removal rate can reach 99.99%. 2. In the waters of viruses, bacteria removal rate of 99.99% under the premise of the cost per ton of water at 4% so far 1 cent yuan (depends on clean water). 3. improve water, fresh water breeding, aquaculture has more than 50% survival rate (survival depends on when no sterilization) 4 speed up the breeding population growth rate. 5. improve the nursery, breeding population overall health, nurture healthy seedlings, healthy adult. 6. Without changing the variety of beverages and other liquid food products of the original ingredients, taste and color, disease, bacteria and other pathogenic body removal rate up to 99.99%. 7 swimming pool water disinfection using ultraviolet light prior to sterilization, chlorine content in water can be reduced to 0.5 mg / l of viral, bacterial removal rate of 99.99%. 8.2 corresponds to the water terminal addition of UV disinfection can be achieved by direct application of water standards. 9. urban wastewater disinfection, the total dropped to 200 bacteria / 100ml or less, E. coli 20 / 100ml or less. Fourth, the best use UV disinfection (1) Water temperature: 5 ℃ ~ 60 ℃; ambient temperature: -5 ℃ ~ 50 ℃; ambient relative humidity: less than 93% (the temperature at 25 ℃) (2) Voltage: AC 220V ± 10V, 50Hz. (3) Drinking water: Water treatment equipment entering its transmittance 1cm of (T254): 95% ~ 100%; the former is lower than the national drinking water quality standards (such as: color higher than 15 degrees, 5 degrees higher than the turbidity iron content higher than 0.3 mg / l), the first to use other methods of purification and filtration to purify compliance after purification by ultraviolet C water treatment equipment. (4) Air-cleaning: After sand filtration or other device processing filtered fresh water, sea water. (5) Sewage: According to the requirements of sterilization, water treatment equipment entering its 1cm transmittance (T254): ≥40%; other requirements to meet the national "Integrated Wastewater Discharge Standard" GB8978-1996 the secondary standard. (6) water to be treated, such as water quality does not meet the above requirements, you should go through the proper pre-treatment, such as flocculation, sedimentation, filtration and other methods to remove water impurities. Fifth, ultraviolet disinfection maintenance and repair (1) regular checks to ensure the normal operation of the UV lamp. (2) 9000 hours of continuous use, or a year later, replace the UV lamp, in order to ensure a high rate of sterilization. Pay particular attention to the UV should continue in the open state, due to repeated opening and closing will seriously affect the life of the lamp. (3) When replacing the UV lamp, first unplug the lamp power, out of the UV lamp. When replacing a new lamp, careful not to touch the new bulb with your fingers quartz glass, because the stain will affect sterilization lights, while the tube was carefully placed in a stainless steel sterilizer. (4) If the water hardness (calcium or magnesium) material, iron or manganese, then the quartz tube needs to be cleaned regularly. After cleaning the quartz tube should wear special plastic gloves and carefully loaded into the quartz tube reaction apparatus, Bahrain should check for leaking seals, plug in the power supply, which ensures stable detection lamp light. Six, installation considerations of a UV disinfection equipment, ultraviolet disinfection device should be placed in an easy to clean and test areas. 2, in order to facilitate the replacement parts, installation of ultraviolet disinfection device, the device should leave some space on either side, depending on a variety of models may be. 3, prohibit let ultraviolet disinfection equipment icing. 4, the recommended ambient temperature does not exceed 60 ℃. 5, when using the power supply 200V / 50Hz outside, please consult your dealer. 6, the maximum working pressure of 0.6Mpa.
Contact Detail
Company Name: Shijiazhuang Guanyu Environmental Protection Equipment ..
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Wang Tingting(Sales Manager)
Telephone Number: 0311-89832698
Company Address: 398 Youyi North Street, Shijiazhuang City, Villa District 47-1, Shijiazhuang City, Hebei Province, China
Zip/Postal Code:
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450