Computer room security monitoring (access control system burglar alarm infrared radio system sound and light)

Computer room security monitoring (access control system burglar alarm infrared radio system sound and light)
Computer room security monitoring (access control system burglar alarm infrared radio system sound and light)
Computer room security monitoring (access control system burglar alarm infrared radio system sound and light)

Larger photo of automa dispenser

Company:Beijing Huasheng Technology Development Co., Ltd.
Information Name: Computer room security monitoring (access control system burglar alarm infrared radio system sound and light)
Update Time:2014-11-20
Validity:8980
Specifications:Computer room security monitoring (access control system burglar alarm infrared radio system sound and light)
Quantity:1111.00
Price Description: RMB/
Inquire Now
Computer room security monitoring (access control system burglar alarm infrared radio system sound and light) computer room access control system computer room infrared radio system computer room burglar alarm sound and light computer room fire smoke detection system editor; (Huasheng Technology Lai Weiguang) and high humidity Harm to the computer equipment is obvious, which is hazardous to low humidity is sometimes more serious. Under the same conditions, the lower the relative humidity, i.e. the drying, the higher the electrostatic voltage, affecting the normal operation of the computer device more obvious. Experiments show that when the relative humidity is 30% computer room, the electrostatic voltage of 5000v, when the relative humidity is 20%, the electrostatic voltage on the 10000V, while the relative humidity dropped to 5 percent, then the electrostatic voltage up to 20000V. So it is necessary at all important parts of the engine room, the installation of temperature and humidity detection module, record the temperature and humidity curve for management staff queries, once found more limited temperature and humidity instantly activate the alarm; remind managers work to adjust the air-conditioned room or adjust settings distribution of equipment, the system can automatically adjust the conditioning of the working setting. Meanwhile curve system records available under the reference room management personnel; to facilitate timely adjustment according to the local temperature and humidity conditions of each season, in a timely manner due to temperature and humidity to prevent unnecessary damage to equipment caused by quality; can easily be found after the problem occurs in accordance with the historical curve problem, easy to solve the problem. The traditional way to detect temperature and humidity temperature and humidity sensor output voltage or current signal is transmitted to a computer via an analog acquisition module, the voltage or current signal during transmission inevitably affected the quality of the wire, transmission distance, electromagnetic interference, resulting in inevitable errors. To ensure that the impact of temperature and humidity detection value not subject to the above factors, we selected 485 temperature and humidity transmitter. Figure multiple room monitoring computer room to customer requirements with the development of IT industry and the Internet, the number of data centers and computer room construction rising, while the construction of a good room maintenance becoming an increasingly important issue. In particular, to work IT infrastructure, such as the exchange of power, UPS, air conditioning, cabinets, computer room environment is a good guarantee uninterrupted operation of IT equipment. General industry room equipment maintenance and operators are very different, they are responsible for IT managers, there is no full-time person in charge, and each customer is vastly different requirements of various industries. undefined computer room solutions and advantages of multiple subsystems introduced include: AC power distribution, both to support UPS, air conditioning, temperature and humidity, water leakage, batteries, fire, images, access control and other single room, also supports multi-room: hierarchical access thousands a room equipment, multi-level architecture design. undefined system architecture diagram of a computer room integration services platform: a unified data stream, data, video, audio and other services into a single service platform for true three-dimensional, full-real: 3D visualization management platform, all IT infrastructure and environment projects visual management. Computer rooms GIS electronic map: support large-scale site equipment operation and maintenance and real-time electronic map embedded devices: Important equipment are used in embedded devices, in order to ensure the stability of the system. Computer room applications and customer benefits program broadcasting a variety of industries, public security, government, medium and large enterprises, financial and other users have deployed our solutions. Program helps managers focus on their core business, making management more scientific and ensure the stable operation of the IT infrastructure for business continuity operation to provide security. The purpose of undefined room monitoring program integrated monitoring system integrated monitoring system Introduction room system The purpose of this system is to protect the normal operation of the center room systems, real-time monitoring of the indicators room environment encountered room blackout, power failure, the ambient temperature is too high , illegal intrusion, fire and other emergency leaking unforeseen circumstances, timely records, queries, and automatic rapid alarm. We are at a high speed information exchange, dissemination of age, information networks have and our daily office and living closely together to learn. Room as an important place for information processing and exchange, and its position is especially important. Ensure the normal operation of each device in the engine room became a very important job, came into the room this purpose a comprehensive monitoring system. Computer room environment monitoring the execution / reference technical specifications and standards GB2887-89 "computer site security requirements" GB50174-93 "computer room design specifications" GBJ16-87 "architectural design code for fire protection" GB50116-98 "automatic fire alarm system design specifications "SJ / T30003-93" computer room construction and acceptance "GB 50054-95" low voltage power distribution design specifications "JJG874-2007" temperature indicator controller "GBJ93-86" Automation Instrumentation selection provisions "HG20507-92" industrial automation instrumentation engineering construction and acceptance "GB50054-95" low voltage power distribution design specifications "JB / T5243-91" industrial control computer system acceptance outline "GB11032-89" AC gapless arrester "ITU.TS.K20:1990" Telecommunications Current capacity of the switching device resistance to over-voltage and over "ITU.TS.K21:1998" user terminal resistance to over-voltage and over-current capability, "said the technical specifications and standards for integrated environmental monitoring our room provides a basis and reference for the full implementation of the room Environmental monitoring has provided a guarantee. Integrated Monitoring a room, room monitoring generally contains room temperature and humidity, water leakage, fire, theft, power supply, UPS, video monitoring. 2, for monitoring the engine room of voltage, current, power and other parameters, you can choose single-phase / three-phase voltage, current transducer, active transmitter, etc. to achieve measurement, monitoring choice for power supply monitor. 3, room monitoring software integrated fully into account the characteristics of various monitoring signals, signals of different user-friendly design and processing: For such as temperature, humidity, voltage, current, power and other analog signals, the software interface displays real-time measurements, alarms set constant, real-time curve, historical curve, generate reports, automatic data storage, data dump Excel files. For switch alarm signals such as leakage alarm, infrared alarm, smoke alarm, power failure alarm, UPS alarms, etc. are displayed using the alarm indicator to light blinks and changes color to alarm signal generator for switch type alarm report can be found at a alarm recording period. 4, video monitoring, an important position in the engine room to install video cameras, you can use general-purpose camera can also be used zoom, focus the ball machine, in order to meet the higher performance monitoring requirements. Through video surveillance software, can be full every corner of the room to monitor the status of support by event / time and other conditions of the query records. Room comprehensive monitoring system to monitor access control systems security: Configure infrared detectors, glass break detectors, for monitoring illegal intrusion alarm 1) The access control system is fully integrated into the monitoring system; 2) should be used with anti-absconds, two-door interaction lock, multi-card door and other features of the product; 3) provides centralized monitoring system personnel permission settings, open / closed, and personnel access to records and inquiries; 4) based on pre-set, the system can display real-time access personnel access and records, and to provide time and attendance functions; 5) If access is abnormal, should be reported by telephone text messages to managers to set, easy to deal with as soon as possible.
Contact Detail
Company Name: Beijing Huasheng Technology Development Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Lai Weiguang(Manager)
Telephone Number: 010-58440007
Company Address: Beijing Shijingshan, Beijing, Beijing, China
Zip/Postal Code: 100041