High Voltage Tester
High Voltage Tester
|
Main features: ■ AC / DC / IR / GB / LC Observing the Comprehensive Test ■ product functional testing can be conducted concurrently (Function Test), up to 20A ■ programmable voltage output and limit value ■ OSC open circuit detection ■ Flashover ■ ■ human protection circuit to detect a variety of scanning devices support dynamic leakage current test standard RS232 interface ■ ■ ■ Large optional GPIB interface panel lock function LCD panel ■ ■ PC software support ■ UL / TUV / CE parameter characteristics: Model 19032 mode DCV / ACV / IR / GB / LC (option) Pressure test output voltage AC: 0.05 ~ 5kV, DC: 0.05 ~ 6kV loaded Resolution 1% + 5V voltage resolution 2V voltage accuracy 1% + 5counts cut off the current AC: 40mA, DC: 12mA current resolution AC: 1μA, DC 0.1μA current accuracy 1% + 5counts frequency 50Hz / 60Hz test time 0.3 ~ 999sec, continiu rise time of 0.3 ~ 99.9sec, off signal mode single output signal voltage DC insulation test : 0.05 ~ 1kV voltage resolution 2V voltage accuracy 2% + 5V IR range 1MΩ ~ 50G impedance resolution 0.1MΩ accuracy 5% impedance grounding resistance test output current AC: 3 ~ 30A current resolution 10mA current accuracy 1% + 5counts GR range of 10 ~ 510mΩ impedance resolution 0.2mΩ impedance Accuracy 1% + 5counts test mode 4-wire measurements compensation 0 ~ 100mΩ ARC detection setting mode &, amp ;, lt ;, SPAN lang = EN-US style = "FONT -SIZE: 9pt "> can be set to detect the current drive AC: 1 ~ 40mA, DC: 1 ~ 12mA AC: 1 ~ 20mA, DC: 1 ~ 12mA minimum pulse width of 10μs approx 40/20/10 / 4μs selective security features quickly Output cut 0.4ms (after NG happen) DC quick release <0.2sec lock password lock GO / NG judgment alarm GO: short beeps; NG: HI, LOW, ARC NG blew Data Hold recent test data memory Step Hold single-step trigger ON / OFF memory storage 10-step 50-step group call 50 100 group calls automatically leakage current scanner (optional) mode LC / VA leakage current DUT input power AC: 300V / 10A (maximum) Short Circuit Protection 10A / 250V (fuse) Current Range 0.1 ~ 590μA / 500 ~ 6000μA current resolution 0.2μA / 2μA current accuracy is 2% + 5counts (DC-5kHz) measurement mode measurement modes Normal, Reverse, Single fault normal, Single fault reverse measurement equipment UL554NP: Medical appliances & equipment UL554P: Medical appliances & equipment UL 1563: Electrical equipment & component UL 2601, IEC 601-1, EN6060-1: Medical appliances & equipment UL3101, UL1950, UL950,, IEC1010, IEC950, EN60950: Experiment & information equipment 5 different kinds human body RC network voltmeter voltage range AC: 0 ~ 300V voltage accuracy 1.5% + 5counts ammeter current range AC: 0.1 ~ 10A current accuracy is 1.5% + 5counts LC on the upper and lower limit 0 ~ 9.99mA, 1μA limit 0 on (resolution) Current ~ on 9.999A VA limit 0 ~ 2200V VA General Specifications Resolution 0.1VA test environment temperature: 0 ℃ ~ 40 ℃ Humidity: ≤80% RH Power Idle: 100W, rated load:> 650W power supply 100V / 120V / 220V (AC ± 10%) / 240V (AC + 5% ~ -10%), 50 / 60Hz Weight about 24 kg Dimensions (W × H × D) 430 × 133 × 470mm
Contact Detail
Company Name: | Huamao Yuan Technology Co., Ltd. |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Miss Peng() |
Telephone Number: | 0755-29630076 |
Company Address: | Bao'an District 47 CRE Kotanyi Fai Building 211, Shenzhen City, Guangdong, China |
Zip/Postal Code: |
Find More Related Products
- Water heater repair, water ..
- _ Water heater repair water..
- Water heater repair | heate..
- Sakura water heater repair ..
- Jinqiao preferential supply..
- Sakura water heater repair ..
- Sakura water heater repair ..
- Sakura water heater repair ..
- Irbesartan (Aprovel) Beijin..
- Glass printing machine indu..
- Where can we buy cost-effec..
- 2015 Green Organic Food Fair
- Bazhou Plasma / cutting fac..