Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

PS1210-GE PS1210-GF PS1210-KT Dytmeter level sensor / transmitter

PS1210-GE PS1210-GF PS1210-KT Dytmeter level sensor / transmitter
PS1210-GE PS1210-GF PS1210-KT Dytmeter level sensor / transmitter
PS1210-GE PS1210-GF PS1210-KT Dytmeter level sensor / transmitter

Larger photo of automa dispenser

Company:Figure Electrical Equipment Co., Ltd. Chengdu about
Information Name: PS1210-GE PS1210-GF PS1210-KT Dytmeter level sensor / transmitter
Update Time:2014-03-19
Validity:365
Specifications:
Quantity:999.00
Price Description: RMB/
Inquire Now
Level gauge, PS1300 Digital input level meter Product Features: 1, LED digital display, input measurement, direct and easy to use, no installation 2, the standard output, current DC 4 ~ 20 mA, voltage DC 0 ~ 5V, 1 ~ 5V, 0 ~ 10V 3, stainless steel structure, or cast aluminum shell, small size, light weight, easy to install, simple wiring, practical 4, using diffused silicon pressure sensors and computer technology 5 compensation, high accuracy, drift small, anti-interference ability, especially inverter interference 6, breathable waterproof cable for drainage, water industry two, level gauge, PS1300 Digital input level meter unique point: three, level gauge, PS1300 number significant input level meter often choose models: PS1300 R-5 m H2O, PS1300R-5 m H2O-GF, PS1300R - 5 m H2O-GFM2, level gauge, PS1300 Digital input level meter Technical parameters: Measuring range : 0 ~ 200 m H2O, commonly: 2m, 3m, 4m, 5m, 10m Signal output: DC 4 ~ 20 m A, 0 ~ 5 V, 1 ~ 5 V, 0 ~ 10 V transfer form: current output wire , three-wire voltage output accuracy: ± 0.5% FS, high accuracy up to ± 0.25% FS Temperature drift: Zero drift: ± 0.01% FS / ℃ full scale drift: ± 0.02% FS / ℃ Repeatability: ± 0.15% FS Hysteresis: ± 0.15% FS Supply Voltage: DC 24V, power supply voltage range: DC 12V ~ 36V intrinsically safe explosion-proof products must be powered by a barrier overload: 150% of the product range, ie 1.5 times the rated pressure range Load capacity: current type ≤ 600Ω, Voltage ≥ 100kΩ Ambient temperature: Non-explosion-proof -10 ℃ ~ 70 ℃, explosion-proof -20 ℃ ~ 40 ℃ Relative Humidity: 5% ~ 95% RH (25 ℃) Atmospheric pressure: 86 kPa ~ 106 kPa Insulation resistance: ≥ 50 MΩ Dielectric strength: Signal terminal on the housing AC / DC 500V Protection class: IP 6 5 Products Terminal: current, Red 1: Power being Vcc, Black 2: Signal output voltage, the red one: Vcc, yellow or green, output, Black: Gnd proof mark: intrinsically safe explosion-proof mark: Ex ia Ⅱ C T6 Ga isolated explosion-proof mark: Ex d Ⅱ B T4 Gb intrinsically safe parameters: Ui = 28V DC, Ii = 93 mA Ci = 44 nF, Li = 0 mH, Pi = 0.65W differential 2500 yuan YT5151-DP YT5151-DR YT5151-HP Dytmeter capacitive pressure, differential pressure transmitter power 400-606-6695 YT5151-AP YT5151-GP YT5151-LT Dytmeter capacitive pressure, differential pressure transmitter power 400-606-6695 YT5151-DP/GP YT5151 Dytmeter capacitive pressure, differential pressure transmitter power 400-606-6695 pressure level measurement principle. 2, the standard two-wire 4-20 mA output current. 3, ultra-small form factor, is ROSEMOUNT1151 improved, the size of the installation is fully compatible with high-precision, low drift, strong anti-interference ability. 4, the use of object: liquid, gas, steam, 5, for measuring differential pressure throttling device, such as orifice plates, nozzles and other flow measurement system to measure the flow rate of a differential pressure transmitter, YT5151DP differential change send technical parameters: 1, the signal output load characteristics (Reference conditions: no migration status, silicone oil filling red liquid, 316 L diaphragm) output signal: DC4 ~ 20mA or DC4 ~ 20mA + @ HART communication transmission forms: wire. Load characteristic diagram: the higher the supply voltage, the stronger with a load capacity 2, linear output measurement accuracy: ± 0.1% FS (on scale 1:1), including linear, variation, hysteresis, repeatability, integrated error. Prescribing output: the output pressure of 4 to 100%, is ± (0.2% of calibrated span +0.05% cap) 3, stability: within six months does not exceed the absolute maximum range of basic errors. 4, humidity: 0 to 100% relative humidity. 5, the temperature range amplifier: -29 ~ 93 ℃ (LT type of -25 ~ 70 ℃), silicone oil filling red measuring element: -40 ~ 104 ℃; flange temperature transmitter irrigation red silicone: 15 ~ 315 ℃ ; ordinary silicone oil:. -40 ~ 150 ℃ 6, cited pressure from the center of the flange NPT1 / 4, center distance 54, the joint NPT1 / 2 or M20X1.5, center distance 50.8,54,57.2. 7, the maximum temperature in the range zero error: Every 56 ℃ for the range of ± 0.5% FS. Namely: Zero drift ≤ ± 0.01% FS / ℃ total impact, including scale error: Every 56 ℃ for the range ± 1.0% FS namely: full-scale drift ≤ ± 0.02% FS / ℃ in the minimum range zero error: Every 56 ℃ for the range of ± 3% FS. The overall impact of including scale error: Every 56 ℃ for the range of ± 3.5% FS 8, vibrations affect the frequency of 0 ~ 200Hz, each g in any direction is ± 0.05% of upper limit of nine, zero drift installation location affect not more than 0.25 kPa, you can check this error had no effect on the range 10 to eliminate structural specifications isolation diaphragm wetted materials: 316L stainless steel, Hastelloy C, Monel or tantalum drain / vent valves: 316L stainless steel, Hastelloy Alloy C, Monel alloy. Flanged head: 316L stainless steel, Hastelloy C, Monel alloy. O-ring contact with the media: fluorine rubber, nitrile rubber filling red liquid: silicone oil. Bolts: Carbon steel, cadmium plated. Electronic circuit Housing: Low-copper aluminum, polyurethane coated aluminum O-ring: NBR, Viton. Paint: Polyurethane electrical connections: with live online test terminals. 11, using the object liquid, gas, steam. 12, measuring range 0 ~ 60 Pa to 0 ~ 40MPa. 13, power supply 15 ~ 45VDC, typically 24VDC. 14, indicating meter pointer indicates 0 to 100% linear scale, or LCD display and LED digital display. 15, Ex-riot level isolation Ex d IIB T4 Gb, or intrinsically safe Ex ia IIC T6 Ga 16, hydrostatic range 1,4,10,16,25,32 MPa. 17, plus or minus the maximum positive migration to migrate to 500% of the minimum adjustment range; minimal negative transfer of 600% of the minimum adjustment range; regardless of the output, the positive and negative migration on its range, the lower limit of the range of no more than limit. 18, the damping characteristic time constant between 0.2s ~ 1.67s continuously adjustable. 19, start time at the minimum range, up to 2 seconds. 20, the volume uptake of less than 0.16 cm3 21, explosion-proof products using environmental products environmental conditions: temperature: -20 ℃ ~ +40 ℃; Relative humidity: 5% to 95%; Atmospheric pressure: 86 ~-106kPa. Intrinsically safe products with barrier parameters: U0 ≤ 28 VDC; I0 ≤ 30mA; P0 ≤ 0.84. 22, commonly used input differential pressure 0 ~ 6KPa, 40KPa, 250KPa. 23, HART Newsletter selectable with digital display, intelligent LED display with HART communication, without operator, direct three-button panel operation, 24 for communication, data storage configuration data storage function, even if the transmitter power-down data can still save 25 applications widely used in petroleum, chemical, electric power, metallurgy, steel, light beer, pharmaceuticals, food, water, water treatment and other industries.
Contact Detail
Company Name: Figure Electrical Equipment Co., Ltd. Chengdu about
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Plum group(Manager)
Telephone Number: 028-87692549
Company Address: Ginza Tower A, Golden House, 555 Golden Rd Jinniu, Chengdu, Sichuan, China
Zip/Postal Code: 610000
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450