TM202-A00-B00-C00-D00-E00-G00
TM202-A00-B00-C00-D00-E00-G00
TM202 axis position / differential expansion of transmission protection table TM202-A00-B00-C00-D00-E00-G00 TM202-A00-B01-C00-D00-E00-G00 TM202-A01-B00-C00-D00-E00-G00 TM202 -A01-B01-C00-D00-E00-G00 TM202-A02-B00-C00-D00-E00-G00 TM202-A02-B01-C00-D00-E00-G00 TM202-A03-B00-C00-D00-E00- G00 TM202-A03-B01-C00-D00-E00-G00 the Fault Monitoring ★ monitoring of rotating machinery rotor axial position or relative thermal expansion. The measured the parameters ★ rotor relative position (displacement) of the bush rotating machinery monitoring of the various sliding bearing unit type ★. Such as steam turbines, fans, compressors, motors, pumps, and so on. ★ suitable for the transformation of the old units. The installation requirements ★ only need the connection for existing eddy current probe system unit connected to ★ new project, set alarm point requires collaboration with OEMs, design, or contact your Piper Aires TM. Electrical indicators: external power supply: 22-30VDC, 00mA require isolated power. 90 ~ 220VAC power supply, 40 ~ 60Hz, 50mA. External eddy current sensor (Sensor): terminal: "A / P":-24V power supply (-VT or POW ER); "B / S: Signal (SIG or OUT);" COM ": the common terminal (COM or GND) . Sensitivity: with eddy current sensor connected. Buffer output (Buf Out): the output of the original signal. Voltage output range :2-18V (non-parity); output impedance: less than 500Ω output sensitivity: with eddy current sensor connected; Maximum transmission distance: 300 meters. Total vibration output (4-20mA): 4-20mA active, drive 750Ω load; 1-5V, active, the output impedance of 250 Ω. Alarm point setting (Normal / Set): the range of 0 - 100% of full scale; M0180-07-0 0 -05-10-02 accuracy: ± 0.1%. Alarm gain:> 60dB linear range of 8mm probe as an example: Range: 2.00mm; range: 0.25mm-2.25mm at. Error: Linearity error: <1% FS (least-squares method, at 25 o C); Temperature Coefficient: <0.1% FS / o C; relay node capacity (Alert / Dang er): Seal: epoxy resin;: 2A/220V AC or 2A/24VDC; resistive load; node types: single-pole double-throw, SPDT; output isolation: 100 0VDC. Alarm delay: 3 seconds running state phototube LED Indicator: Green: Self-test passed, the meter is working properly; yellow light: alarm indication; red light: Interlocking instructions. Alarm reset / alarm bypass (RESET): Monitoring table built-in alarm reset button; remote alarm reset / alarm the bypass terminals ("RESET"). Nanjing Chun Ding Electric Co., Ltd. Contact: Amaryllis light 18,652,048,568 business telephone 025 -66039810 Fax :025 -52,281,580 Mobile: 18652048568 Business QQ: 840422601 business mailbox: 840422601@qq.com
Contact Detail
Company Name: | Jun Ding Electric Co., Ltd. Nanjing |
---|---|
Employee Number: | |
Annual export: | |
Year Established: | |
Contact Person: | Mr. Zhu Top light(Sales Engineer) |
Telephone Number: | 025-68621775 |
Company Address: | Jiangning Tianyuan East Road No. 288 Building, A-1190 Apple City Room, Nanjing, Jiangsu Province, China |
Zip/Postal Code: | 211100 |
Find More Related Products
- Supply a second-hand hardwa..
- The Turck-site professional..
- Supply Sanshan force brand ..
- Supply Fujian aerated steam..
- Genhe supply manufacturers,..
- Supply how to register Hong..
- Beams strengthened with car..
- Thigh at the erythema jock ..
- Automatically walk gasoline..
- Dongfeng DLK sewage suction..
- Shenzhen to Tynemouth Expre..
- Minzhi thermostat wine cool..
- To supply the Shaoyang meth..
- Supply Zhuhai Square bicycl..
- Dalian cost of staff traini..
- How to quickly remove the a..
- Shandong methanol gasoline ..
- Leading large slides - wate..
- Supply of PX211-1F4X1 cheap..
- The Xinjiang Coke linear vi..