Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

To supply Japan omron safety light curtains price security screens Model

To supply Japan omron safety light curtains price security screens Model
To supply Japan omron safety light curtains price security screens Model
To supply Japan omron safety light curtains price security screens Model

Larger photo of automa dispenser

Company:Leehom Safety Equipment (Shanghai) Co., Ltd.
Information Name: To supply Japan omron safety light curtains price security screens Model
Update Time:2013-01-11
Validity:300
Specifications:f3sn
Quantity:100.00
Price Description: RMB/
Inquire Now
The security products Lihong security provide a full range of security products, we set one of the European and American security products, customers choose and buy, you can directly enter the the Lihong site security product Mall Products Shop, the Lihong Security (LHS) agent a global the EHS professional security products, Lihong website security product Mall, a collection of more than a dozen security products companies, including OMRON, STI, SICK, PILZ, ABB, AB, CASTELL, HONEYWELL, PLYMOVENT, LHS F3SJ-B Safelight curtain F3SJ-E (Simple) can be used for simple palm intrusion detection. Change models needed for installation time only half of the traditional products. Glance diagnostic results, simplified safety light curtain product features a simple, but high reliability. F3SJ-B safety light curtain shielding function security screens used in a variety of production environments. Installation is flexible, up to three sets of safety light curtains can be connected in series. F3SJ-B safety light curtain F3SJ-E (Simple) can be used for simple palm intrusion detection. Change models needed for installation time only half of the traditional products. Glance diagnostic results, simplified safety light curtain product features a simple, but high reliability. F3SJ-B (basic) shielding functions to achieve the security screens used in a variety of production environments. Installation is flexible, up to three sets of safety light curtains can be connected in series. F3SJ-B safety light curtain in the power-on self-diagnostic function to perform self-diagnosis to check for errors. In addition, during operation, but also timing perform self-diagnosis (response time). F3SJ-B safety light curtains external test function using an external signal to stop light projection. When F3SJ interrupt can be used to verify the security system should correct stop. The functions of the external device monitoring function for checking the malfunction, for example to control the machine dangerous part of the external relay (or contactor) whether welding. This feature continuously monitors whether there is a predetermined voltage is applied to the input lines of the external devices monitoring optical receiver, and the system enters the interlocked state when an error occurs. The relay action delay not to be identified as the error longest time 300ms. For example, if the security output from ON to OFF after the normally closed (NC) contact is not closed in the 0.3s, and not specified voltage is applied to the external device monitoring circuit, the situation will be identified as wrong, and the system will enter interlock state. In order to properly use this feature, please use the relays and contactors with forcibly guided or mechanical linkage connecting the contact structure. F3SJ-B light curtain safety interlock function when the power is turned or the optical axis of the shelter, remain behind the F3SJ will safety output is set OFF, and remain in that state until a reset input is applied. This state is called "interlock". There are two methods can be used to reset the interlock state, i.e., will result in the occlusion of the object is removed after the automatic control output turns ON the "automatic reset method", and will cause the occlusion of the object is removed, the control output is kept OFF until the reset signal until manually reset method is applied. F3SJ-B safety light curtains automatically reset will cause occluded objects away from the detection area, the safety output will be automatically set to ON. When the region between the workers can not enter the dangerous parts of the detection zone and the machine, using the automatic reset method. Safety light curtain F3SJ-B manual reset detection caused by occlusion of the objects do not exist in the district imposed a reset input, so that the safety output is set ON. This function can be provided after the confirm security, so that the machine manually reset by a reset switch, thereby preventing unnecessary startup. Auxiliary output function auxiliary output functions for monitoring F3SJ state. The output can be connected to a devices like programmable controller. F3SJ-B safety light curtain shielding function masking function allows the F3SJ the security feature is temporarily unavailable, which can be maintained even in the case of optical axis blocked safety output is ON. The function for the the AGV channel install security screens, which take into account the safety and productivity. Override function override function does not meet the safety shield start conditions the output is set ON. Workpiece stopped by F3SJ the process (see below) and lead shielding error can not be restored to its normal state, unless the workpiece away from the detection area of ??the shield sensor and F3SJ. But override function will shield the output of the F3SJ the security, so that the conveyor can be restarted and thus removed from the workpiece shielded sensors and detection area. Partial shielding function partial shielding function to ensure the security, without the need to shield enabled through the optical axis of the workpiece. The position detection shielded when the robot is in a safe position limit switches or other measures, then shielding function is enabled. Safety light curtain F3SJ-B fixed blanking function fixed blanking feature enables the F3SJ the specific optical axis invalid. This function even in some parts of the machinery and equipment in the detection region, and also enable the safety output remains ON. Floating blanking function floating blanking function can increase the F3SJ the detection radius, so as to enhance its detection capabilities, and make security checks to multiple objects output is set to OFF. If a fixed width of moving objects but do not need to detect the objects in the detection area, will enable the detection function is invalid. F3SJ-B safety light curtains warning zone detection area is divided into the detection area and alarm zone. When the object enters the warning zone, at lights or buzzer alarm will sound, without having to stop the machinery and equipment. Setting tools can be purchased the following setting tool (sold separately) for the various parameters of the change or confirm F3SJ-A. F39-MC21 handheld programmer supply F3SJ-B Safety Light Curtains (F3SJ-E1025N25) safety light curtain F3SJ-B Series light curtain price supply F3SJ-B Safety Light Curtains (F3SJ-E1025N25) safety light curtain F3SJ-B Series light curtain price F3SJ- B safety light curtain function distinction: F3SJ-A the F3SJ-B F3SJ-of E Safety Level 4 4 4 minimum detection capability 14mm minimum 25mm minimum 25mm detect magnitude maximum 2470mm maximum 2065mm maximum 1105mm special features blanking shield shield free connection connector type connector type wired ========================================= ====================================== F3SJ-B safety light curtain models table: F3SJ-A0425P14 F3SJ-A0911N14 F3SJ-A0533N14 F3SJ-A0443P14 F3SJ-A0983N14 F3SJ-A0551N14 F3SJ-A0461P14 F3SJ-A1055N14 F3SJ-A0569N14 F3SJ-A0479P14 F3SJ-A1127N14 F3SJ-A0587N14 F3SJ-A0497P14 F3SJ-A1199N14 F3SJ-A0299N14 F3SJ-A0515P14 F3SJ-A1271N14 F3SJ- A0317N14 F3SJ-A0533P14 F3SJ-A1343N14 F3SJ-A0335N14 F3SJ-A0551P14 F3SJ-A1415N14 F3SJ-A0353N14 F3SJ-A0569P14 F3SJ-A1487N14 F3SJ-A1127P14 F3SJ-A0587P14 F3SJ-A1559N14 F3SJ-A1199P14 F3SJ-A0605P14 F3SJ-A1631N14 F3SJ-A1271P14 F3SJ-A0623P14 F3SJ -A0245P14 F3SJ-A1343P14 F3SJ-A0659P14 F3SJ-A0263P14 F3SJ-A0695P14 F3SJ-A1415P14 F3SJ-A1487P14 F3SJ-A0731P14 F3SJ-A0911P14 F3SJ-A1559P14 F3SJ-A0767P14 F3SJ-A0983P14 F3SJ-A1631P14 F3SJ-A0803P14 F3SJ-A1055P14 F3SJ-A0245N20 F3SJ-A0839P14 F3SJ-A0305N20 F3SJ-A0275N20 F3SJ-A0875P14 F3SJ-A0263N14 F3SJ-A0281N14 =================================== ============================================ of Lihong safety equipment works ( Shanghai) Co., Ltd. lihong (shanghai) safety co, ltd wendy Jin Wenting Mol: 13,764,457,668 Tel: +86-021-58316693-823 Fax: +86-021-5831-6659 Email: wendy@lh-safety.com Add: Shanghai Room 518, 489 Pudian Pudong Lujiazui
Contact Detail
Company Name: Leehom Safety Equipment (Shanghai) Co., Ltd.
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Jin Wenting(Sell)
Telephone Number: 021-58316637-823
Company Address: Shanghai Pudong New Area by the pump circuit No. 489 from the Martin Bridge Building, Shanghai, Shanghai, China
Zip/Postal Code: 200122
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450