Login | Join Free | Post supplying Leads | Post Buying Leads | Help | China Site China Business News
Home Products

Hangzhou City under air conditioning and fluoride under the city near the air-conditioning maintenance of telephone / installation / cleaning

Hangzhou City under air conditioning and fluoride under the city near the air-conditioning maintenance of telephone / installation / cleaning
Hangzhou City under air conditioning and fluoride under the city near the air-conditioning maintenance of telephone / installation / cleaning
Hangzhou City under air conditioning and fluoride under the city near the air-conditioning maintenance of telephone / installation / cleaning

Larger photo of automa dispenser

Company:Hangzhou Haier air conditioning repair company
Information Name: Hangzhou City under air conditioning and fluoride under the city near the air-conditioning maintenance of telephone / installation / cleaning
Update Time:2012-12-26
Validity:30
Specifications:Hangzhou City under air conditioning and fluoride, near Hangzhou City under air conditioning maintenance of telephone
Quantity:1.00
Price Description: RMB/
Inquire Now
Hangzhou City under fluoridation telephone, air conditioning and fluoride Hangzhou City under air conditioning, air conditioning repair company Hangzhou products today, air conditioning fluoridation common sense empty investigate leakage skills: focus on pipeline leak grease parts of the leak, check the leakiness site , such as split-type air conditioning leaky weld point in the connecting pipe nozzle, the outdoor unit. Leak, followed by checking the outdoor unit connecting pipe cutoff nozzle indoor unit connected to the nozzle, the connecting pipe extension tube weld, the outdoor unit weld, the indoor unit weld. 1. System pressure leak. Air conditioning so the refrigerant lines can be seen directly, more than 95% of its leak point of discoloration and grease, and the relatively high pressure of the air conditioning refrigerant F22, to meet the leak detection requirements. In the case of non-boot, washing flexible soapy smear in the refrigeration system parts grease or suspected leak site, if bubbles appear, indicating that the premises leaks. Hangzhou City under air conditioning fluoridation raise a small amount of refrigerant leak, exclusive leaked more serious air conditioning, raise a small amount of refrigerant leak before it, near the increased pressure within the refrigeration system to meet the check leakage needs washing flexible foam water coated in grease or suspected leak points parts, such as air bubbles, and then the same newspaper on tainted point of the site. 3 restructuring compressor suppress the leak, the low pressure cut-off side of the air-conditioning repair port installed on the service valve, pressure gauge components, and then restructuring the compressor low pressure tube vacant, high-pressure pipe installation service valve, plug in the power supply of the restructuring compressor it strengths operation, compressed air fed to the air mass system, When the pressure gauge shows a pressure of 0.8-1.2 Pa, the dwell period of time, if the pressure gauge readings, as can be illustrated by the refrigeration system Youlou . Fluoride air conditioning installation quality are inseparable, Yang, who lives in Hangzhou recently broken the "heart" for the operation of air conditioning at home, around the beginning of July, Mr. Yang open dusty air conditioning for six months suddenly found near the air conditioning blowing out wind refrigeration poorly, he immediately called hired the maintenance staff, Hangzhou City under air conditioning fluoridation phone in minor overhaul and took away 300 yuan fluoridation costs, air-conditioning of the Yang family temporarily restore the use of maintenance personnel. A month later, the air-conditioning of the Yang family appeared in the same situation, the maintenance staff said that it would add $ 450 freon, Mr. Yang was very angry. Later, Mr. Yang got a professional air conditioning maintenance personnel through a friend, the other side said that the lack of fluoride air conditioning, resulting in leakage of fluorine phenomenon is very serious because the installation is not appropriate, in The Professionals reinstall, home air conditioning until Mr. Yang no problems. Home air conditioning and fluoride methods of operation: 1, three-way repair valve and the connection table installed first, after the three-way valve closed. 2, then you can boot refrigeration, in order to reduce the pressure back to the trachea. 3, open the air-conditioned the fluoridation hole, use a wrench, bend the head connection, note that the three-way valve must be closed near or air conditioning fluorine escaping (the three-way valve may also exist leak possible, Hangzhou City under air conditioning and fluoride connection to check). 4, when you can see your gauge readings, normally between 0.4 to 0.6 (black scale). Below 0.4 should be less, depending on the circumstances (such as the cooling effect is not good) about the fluoridation of higher than 0.6. 5, but in principle, slightly open the three-way valve, let the air of the original red tube ran out, air conditioning repair not like where the air conditioner does not allow air, be careful not to play too large, otherwise Freon and chilled liquid will run out of. General gas out enough, and then close the valve. 6 cylinders processing fluorine pipe connections. 7, fluoridation pipe and three-way repair valve connection, the first not then completely dead. 8, open the cylinder. Air tube fluoridation same discharge, close the cylinder, connected, and then open the cylinder 9 next fluoridation, open the three-way repair valves, Hangzhou City under air conditioning and fluoride plus phone depending on the circumstances, the principle many times less plus. 10, the whole process of air conditioning always on home air conditioning (cooling) Fluoridation other matters: 1. Such as when the cooling effect is not good does not mean lack of fluoride air conditioning may be worrying too much to too much dust, air conditioner failure. 2. If the air conditioning pipe leakage fluoridation can not solve the problem, or to repair yo. You can not look bad connector. 3. Connector leak detection method, a small amount of detergent plus water, mess with a dish sponge foam, then the foam Full foam to the outer connector (see small picture, the red arrow at all joints), look at the joints vesicles blowing some words can solve, website building, near the wrench to tighten a try. 4. In the case of no security measures, please do not high-altitude operations, near Hangzhou City under air conditioning maintenance of telephone or unsafe operations at low altitude, solid wood bathroom cabinet. Home air conditioning and fluoride supplement fluoride benefits, improve the heating capacity of air conditioning and refrigeration, saving, increase the life of the air conditioning and the useful life of the air conditioning cleaning methods, after a period of use, the air conditioning filters, evaporator and air supply the system will accumulate large amounts of dust, dirt, and produce large amounts of bacteria, viruses. These harmful substances in the air in the indoor cycle, pollute the air, spread disease, serious harm to human health. Near and dirt will reduce the air-conditioning refrigeration efficiency and increased energy consumption, shorten the service life of air conditioning. Therefore, the air conditioning in use for some time or seasonal downtime must be cleaned. In order to ensure that you have a healthy, clean air environment. , Tank air cleaning method, the Guiji's first panel removed, find air conditioning evaporator, after shaking the special foam cleaning agent sprayed in the air conditioning evaporator, and then covered with the panel and let stand about 10 minutes , turned on the air conditioning and the of a lookout amount of cooling capacity to the maximum, to keep open the air conditioning 30 minutes. Hangzhou City under air conditioning fluoride Address To avoid outlet blow out some of the foam and dirt that can be used a damp cloth to cover the vent. After cleaning: air conditioning evaporator dust, dirt, germs are gone, the air becomes fresh, clean and cool, more energy-saving air-conditioning, the family's health protection. Window air conditioner cleaning method, disconnect the air conditioning power supply, removed a window air conditioner, open the cover, remove the filter and wash away the dust. Shake special foam cleaning agent sprayed If the dirt is too much, can be used wet erase, or wash with a small amount of water at the inlet side of the air conditioning evaporator. Fitted with filters, the closed panel let stand for 10 minutes, turn the air conditioning and the of a lookout amount of cooling capacity to the maximum, to keep open the air conditioning 30 minutes, you can. , Split air conditioning cleaning methods, Hangzhou City under air conditioning fluoridation professional disconnect the air conditioning power, near open the cover, remove the filter and wash away the dust. Shake special foam cleaning agent sprayed If the dirt is too much, can be used wet erase, or wash with a small amount of water at the inlet side of the air conditioning evaporator. Fitted with filters, the closed panel let stand for 10 minutes, turn the air conditioning and the of a lookout amount of cooling capacity to the maximum, to keep open the air conditioning 30 minutes, you can. With the increased use of air conditioning, air conditioning use a lot of problems, one of the most common air conditioning lack of fluoride. This article describes the knowledge about air conditioning fluoridation. Steps / methods 1, turn on the air conditioning; summer fluoride directly to the air conditioning cooling mode operation. Fluoridation operation can not be the state of the heating, winter fluoridation the hot pull valve line, use the system near to force air into the refrigeration state. 2, connected fluoridation equipment; air conditioning started from the the craft port side of the low pressure valve of the outdoor unit plus fluorine device is connected. This process must drain fluoride tube of air and dirt. 3, manometry plus fluorine; observed low pressure in the summer, the ambient temperature of 32 degrees Celsius, the pressure is controlled at about 0.45mp; observe the heating in the winter when the high pressure, stable pressure is controlled at about 1.7mp. 4, removed the fluoridation equipment; remove the state of the system Ling fluoridation equipment, sealed satisfied sub tighten foreign plane; heating state to remove the device will cause a lot of Freon leaks. 5, air conditioning the fluoridation price in Hangzhou city air conditioning repair company near Tel 50-200 yuan. The best professional air conditioning fluoridation technicians. Hangzhou home air conditioning use long need to be cleaned once the air conditioner indoor section equipped with a filter to filter out dust, fibers, fumes in the air. Filters are generally made of plastic material, filter dust excessive increase indoor air intake air resistance, affect the amount of wind and indoor circulating air volume. When over the strainer mesh due to the circulating air is greatly reduced too much dust clogging the evaporator can not be normal for heat exchange, air conditioner cooling capacity is significantly reduced. More occasions in indoor dust, regular cleaning of dust filters. General household air conditioners, air conditioning fluoridation of Hangzhou City under more than fumes near the sand to larger areas, air conditioner use 200 hours, washable filter. Fumes, sand or fiber scattering occasions to work 100 hours less cleaning time. With some air conditioner filter cleaning remind indication indicator appears after cleaning. Filter cleaning should be carried out according to the instructions on the procedures. Window air conditioner is generally Pinch filter handle near Gently pull the filter. Split air conditioner, generally off the panel, and then to see the handle, remove the filter and filter online only dust, fibers, can gently wiped or vacuumed dust off. The Hangzhou City air conditioning and fluoride Which good if pollution is serious, or fumes, with a mild detergent to avoid damage to the filter washed, dried and carefully loaded into the place.
Contact Detail
Company Name: Hangzhou Haier air conditioning repair company
Employee Number:
Annual export:
Year Established:
Contact Person: Mr. Wang Ming(Business Manager)
Telephone Number: 56675017
Company Address: The Hangzhou Wangjiang outside Zhijie, 127-2, Hangzhou City, Zhejiang, China
Zip/Postal Code: 310000
About us | Partnership | Services | Payment | Contact Us | Site Map | Help
International Sites: International Site | China Site | CG160 | YPSort
Terms & Conditions - Disclaimer Copyright © 1999 - B2B168.Com Ltd. All rights reserved. ICP B2-10089450